When Polyethylene Exchange Is Appropriate for Prosthetic Knee Instability

被引:14
作者
Fehring, Thomas K. [1 ]
Baird, Robert, III [2 ]
Park, Brian [3 ]
Della Valle, Craig [4 ]
机构
[1] OrthoCarolina Hip & Knee Ctr, Charlotte, NC 28207 USA
[2] Orthopaed Grp, Oakland, CA USA
[3] Kaiser Permanente, Dept Reconstruct Surg, Oakland, CA USA
[4] Rush, Midwest Orthopaed, Chicago, IL USA
来源
JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS GLOBAL RESEARCH AND REVIEWS | 2019年 / 3卷 / 05期
关键词
TIBIAL INSERT EXCHANGE;
D O I
10.5435/JAAOSGlobal-D-19-00031
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Introduction: Prosthetic knee instability is a common cause of patient dissatisfaction and early failure after total knee arthroplasty (TKA). Strategies to manage such instability are dependent on the recognition of the presenting instability pattern because some require full revision, whereas others can be managed by polyethylene exchange (PE) only. This retrospective chart review classifies and reports on a series of patients where PE only was used to manage an unstable TKA. Methods: Of 1606 revision TKA patients, 4% underwent an isolated PE for prosthetic knee instability. All cases were classified using the novel OrthoCarolina Prosthetic Knee Instability Classification System. This classification system was established to guide surgeons in the diagnosis and surgical management of periprosthetic knee instability. The final data set included 41 patients at an average follow-up of 43 months. Results: Of the patients treated with poly exchange only for an appropriate indication (ie, coronal instability with competent ligaments or global instability), 63% felt their knee was stable, whereas 37% felt they remained unstable after revision. Additionally, only 59% had improvement in their pain, whereas 41% were dissatisfied with their pain relief after revision. Discussion: Despite the use of this technique when indicated, the results of PE only with regard to pain and instability are unpredictable. Only approximately 50% of patients became stable and had adequate pain relief. Patients and surgeons alike should understand that this low morbidity option does not guarantee a good result regardless of whether it is used for an appropriate indication. Obtaining stability and pain relief in a patient with prosthetic knee instability remains a significant challenge. Therefore, the key to avoiding prosthetic knee instability is through prevention at the time of primary surgery. Prosthetic knee instability remains difficult to manage despite intuitive and appropriate indications for PE only.
引用
收藏
页数:5
相关论文
共 8 条
[1]   The effectiveness of isolated tibial insert exchange in revision total knee arthroplasty [J].
Babis, GC ;
Trousdale, RT ;
Morrey, BF .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (01) :64-68
[2]   Outcome After Isolated Polyethylene Tibial Insert Exchange in Revision Total Knee Arthroplasty [J].
Baker, Richard P. ;
Masri, Bassam A. ;
Greidanus, Nelson V. ;
Garbuz, Donald S. .
JOURNAL OF ARTHROPLASTY, 2013, 28 (01) :1-6
[3]   Polyethylene exchange only for prosthetic knee instability [J].
Brooks, AH ;
Fehring, TK ;
Griffin, WL ;
Mason, JB ;
McCoy, TH .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (405) :182-188
[4]  
Fehring TK, 2001, CLIN ORTHOP RELAT R, P315
[5]   Outcome of isolated tibial polyethylene insert exchange after uncemented total knee arthroplasty - 27 patients followed for 8-71 months [J].
Jensen, Claus L. ;
Petersen, Michael M. ;
Jensen, Karl E. ;
Therbo, Matthias ;
Schroder, Henrik M. .
ACTA ORTHOPAEDICA, 2006, 77 (06) :917-920
[6]   Outcome of isolated polyethylene tibial insert exchange after primary cemented total knee arthroplasty [J].
Konrads, Christian ;
Brieske, Stefanie ;
Holder, Michael ;
Walcher, Matthias ;
Rudert, Maximilian ;
Hoberg, Maik .
INTERNATIONAL ORTHOPAEDICS, 2015, 39 (06) :1093-1097
[7]  
Raab Gregory E, 2009, Orthopedics, V32, P318
[8]   Why are total knee arthroplasties failing today? [J].
Sharkey, PF ;
Hozack, WJ ;
Rothman, RH ;
Shastri, S ;
Jacoby, SM .
CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2002, (404) :7-13