Continuous glucose monitoring by means of fiber-based, mid-infrared laser spectroscopy

被引:33
作者
Lambrecht, A.
Beyer, T.
Hebestreit, K.
Mischler, R.
Petrich, W.
机构
[1] Fraunhofer Inst Phys Measurement Tech IPM, D-79110 Freiburg, Germany
[2] Roche Diagnost GmbH, D-68305 Mannheim, Germany
[3] Heidelberg Univ, Fac Phys & Astron, D-69122 Heidelberg, Germany
关键词
mid-infrared; glucose; spectroscopy; quantum cascade lasers;
D O I
10.1366/000370206777887071
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The application of mid-infrared laser spectroscopy to the reagent-free quantification of the concentration of glucose was investigated using cryogenically cooled lead salt lasers or, alternatively, quantum cascade lasers operating at room temperature. The concentration of glucose in aqueous solutions was quantified by means of fiber-based attenuated total reflection (ATR) spectroscopy (fiber-optical evanescent field analysis FEFA) as well as fiber-based transmission spectroscopy. Both methods have the potential to be utilized by small fiber sensors, which can be inserted into the subcutaneous tissue in order to continuously measure the local concentration of glucose. In our in vitro experiments. noise-equivalent concentrations as low as 10 mg/dL were achieved. The midterm stability of the measurement schemes was investigated by means of Allan variance analysis. Based on the research presented in this manuscript, an all-room-temperature measurement scheme using quantum cascade lasers, miniaturized fiber-optic sensors, and pyroelectric detectors appears well suited for the continuous monitoring of glucose concentrations at physiological levels.
引用
收藏
页码:729 / 736
页数:8
相关论文
共 35 条
[1]   Continuous wave operation of a mid-infrared semiconductor laser at room temperature [J].
Beck, M ;
Hofstetter, D ;
Aellen, T ;
Faist, J ;
Oesterle, U ;
Ilegems, M ;
Gini, E ;
Melchior, H .
SCIENCE, 2002, 295 (5553) :301-305
[2]   Fast gas spectroscopy using pulsed quantum cascade lasers [J].
Beyer, T ;
Braun, M ;
Lambrecht, A .
JOURNAL OF APPLIED PHYSICS, 2003, 93 (06) :3158-3160
[3]   IR-biosensor:: flat silver halide fiber for bio-medical sensing? [J].
Bindig, U ;
Meinke, M ;
Gersonde, I ;
Spector, O ;
Vasserman, I ;
Katzir, A ;
Müller, G .
SENSORS AND ACTUATORS B-CHEMICAL, 2001, 74 (1-3) :37-46
[4]   LONG-TERM CONTINUOUS GLUCOSE MONITORING WITH MICRODIALYSIS IN AMBULATORY INSULIN-DEPENDENT DIABETIC-PATIENTS [J].
BOLINDER, J ;
UNGERSTEDT, U ;
ARNER, P .
LANCET, 1993, 342 (8879) :1080-1085
[5]   Infrared evanescent field sensing with quantum cascade lasers and planar silver halide waveguides [J].
Charlton, C ;
Katzir, A ;
Mizaikoff, B .
ANALYTICAL CHEMISTRY, 2005, 77 (14) :4398-4403
[6]   EVALUATING CLINICAL ACCURACY OF SYSTEMS FOR SELF-MONITORING OF BLOOD-GLUCOSE [J].
CLARKE, WL ;
COX, D ;
GONDERFREDERICK, LA ;
CARTER, W ;
POHL, SL .
DIABETES CARE, 1987, 10 (05) :622-628
[7]   Glucose quantification in dried-down nanoliter samples using mid-infrared attenuated total reflection spectroscopy [J].
Diessel, E ;
Willmann, S ;
Kamphaus, P ;
Kurte, R ;
Damm, U ;
Heise, HM .
APPLIED SPECTROSCOPY, 2004, 58 (04) :442-450
[8]   Quantum cascade semiconductor infrared and far-infrared lasers: from trace gas sensing to non-linear optics [J].
Duxbury, G ;
Langford, N ;
McCulloch, MT ;
Wright, S .
CHEMICAL SOCIETY REVIEWS, 2005, 34 (11) :921-934
[9]   Towards functional group-specific detection in high-performance liquid chromatography using mid-infrared quantum cascade lasers [J].
Edelmann, A ;
Ruzicka, C ;
Frank, J ;
Lendl, B ;
Schrenk, W ;
Gornik, E ;
Strasser, G .
JOURNAL OF CHROMATOGRAPHY A, 2001, 934 (1-2) :123-128
[10]   High-temperature, high-power, continuous-wave operation of buried heterostructure quantum-cascade lasers [J].
Evans, A ;
Yu, JS ;
David, J ;
Doris, L ;
Mi, K ;
Slivken, S ;
Razeghi, M .
APPLIED PHYSICS LETTERS, 2004, 84 (03) :314-316