Portable Optical Epidural Needle-A CMOS-Based System Solution and Its Circuit Design

被引:5
作者
Gong, Cihun-Siyong Alex [3 ,4 ]
Lin, Shih-Pin [1 ,2 ]
Mandell, M. Susan [5 ]
Tsou, Mei-Yung [1 ,2 ]
Chang, Yin [6 ]
Ting, Chien-Kun [1 ,2 ]
机构
[1] Taipei Vet Gen Hosp, Dept Anesthesiol, Taipei, Taiwan
[2] Natl Yang Ming Univ, Taipei 112, Taiwan
[3] Chang Gung Univ, Coll Engn, Sch Elect & Comp Engn, Dept Elect Engn, Taoyuan, Taiwan
[4] Chang Gung Univ, Coll Engn, Green Technol Res Ctr, Portable Energy Syst Grp, Taoyuan, Taiwan
[5] Univ Colorado, Hlth Sci Ctr, Dept Anesthesiol, Aurora, CO USA
[6] Natl Yang Ming Univ, Inst Biomed Engn, Taipei 112, Taiwan
关键词
SPACE; IDENTIFICATION; ANALGESIA;
D O I
10.1371/journal.pone.0106055
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Epidural anesthesia is a common anesthesia method yet up to 10% of procedures fail to provide adequate analgesia. This is usually due to misinterpreting the tactile information derived from the advancing needle through the complex tissue planes. Incorrect placement also can cause dural puncture and neural injury. We developed an optic system capable of reliably identifying tissue planes surrounding the epidural space. However the new technology was too large and cumbersome for practical clinical use. We present a miniaturized version of our optic system using chip technology (first generation CMOS-based system) for logic functions. The new system was connected to an alarm that was triggered once the optic properties of the epidural were identified. The aims of this study were to test our miniaturized system in a porcine model and describe the technology to build this new clinical tool. Our system was tested in a porcine model and identified the epidural space in the lumbar, low and high thoracic regions of the spine. The new technology identified the epidural space in all but 1 of 46 attempts. Experimental results from our fabricated integrated circuit and animal study show the new tool has future clinical potential.
引用
收藏
页数:8
相关论文
共 18 条
[1]   Low power Schmitt trigger circuit [J].
Al-Sarawi, SF .
ELECTRONICS LETTERS, 2002, 38 (18) :1009-1010
[2]  
[Anonymous], 2003, The Statistical Evaluation of Medical Tests for Classification and Prediction
[3]   A MULTIFACTORIAL ANALYSIS TO EXPLAIN INADEQUATE SURGICAL ANALGESIA AFTER EXTRADURAL BLOCK [J].
CURATOLO, M ;
ORLANDO, A ;
ZBINDEN, AM ;
SCARAMOZZINO, P ;
VENUTI, FS .
BRITISH JOURNAL OF ANAESTHESIA, 1995, 75 (03) :274-281
[4]   Epidural needle with embedded optical fibers for spectroscopic differentiation of tissue: ex vivo feasibility study [J].
Desjardins, Adrien E. ;
Hendriks, Benno H. W. ;
van der Voort, Marjolein ;
Nachabe, Rami ;
Bierhoff, Walter ;
Braun, Guus ;
Babic, Drazenko ;
Rathmell, James P. ;
Holmin, Staffan ;
Soderman, Michael ;
Holmstrom, Bjorn .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (06) :1452-1461
[5]   ANESTHETIC AND OBSTETRIC OUTCOME IN MORBIDLY OBESE PARTURIENTS [J].
HOOD, DD ;
DEWAN, DM .
ANESTHESIOLOGY, 1993, 79 (06) :1210-1218
[6]   Real-time ultrasound-guided paramedian epidural access: evaluation of a novel in-plane technique [J].
Karmakar, M. K. ;
Li, X. ;
Ho, A. M. -H. ;
Kwok, W. H. ;
Chui, P. T. .
BRITISH JOURNAL OF ANAESTHESIA, 2009, 102 (06) :845-854
[7]   A Modular and Programmable Development Platform for Capsule Endoscopy System [J].
Khan, Tareq Hasan ;
Shrestha, Ravi ;
Wahid, Khan A. .
JOURNAL OF MEDICAL SYSTEMS, 2014, 38 (06)
[8]  
Konrad C, 1998, ANESTH ANALG, V86, P635
[9]   The use of receiver operating characteristic curves in biomedical informatics [J].
Lasko, TA ;
Bhagwat, JG ;
Zou, KH ;
Ohno-Machado, L .
JOURNAL OF BIOMEDICAL INFORMATICS, 2005, 38 (05) :404-415
[10]   Discriminant analysis for anaesthetic decision-making: an intelligent recognition system for epidural needle insertion [J].
Lin, S. P. ;
Mandell, M. S. ;
Chang, Y. ;
Chen, P. T. ;
Tsou, M. Y. ;
Chan, K. H. ;
Ting, C. K. .
BRITISH JOURNAL OF ANAESTHESIA, 2012, 108 (02) :302-307