Extended use of the intrauterine device: a literature review and recommendations for clinical practice

被引:76
作者
Wu, Justine P. [1 ]
Pickle, Sarah [1 ]
机构
[1] Rutgers Robert Wood Johnson Med Sch, Dept Family Med & Community Hlth, New Brunswick, NJ 08901 USA
关键词
Intrauterine device; Copper IUD; Levonorgestrel intrauterine system; LNG-IUS; Extended use; Prolonged use; Copper T; SIMULATED UTERINE FLUID; LONG-TERM USE; UNITED-STATES; COPPER CORROSION; TCU; 380A; T IUDS; LEVONORGESTREL; CONTRACEPTION; RELEASE; SYSTEM;
D O I
10.1016/j.contraception.2014.02.011
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
There are multiple advantages to "extended use" of the intrauterine device (IUD) use beyond the manufacturer-approved time period, including prolongation of contraceptive and non-contraceptive benefits. We performed a literature review of studies that have reported pregnancy outcomes associated with extended use of IUDs, including copper IUDs and the levonorgestrel intrauterine system (LNG-IUS). Among parous women who are at least 25 years old at the time of IUD insertion, there is good evidence to support extended use of the following devices: the TCu380A and the TCu220 for 12 years, the Multiload Cu-375 for 10 years, the frameless GyneFixe (R) (330 mm(2)) for 9 years, the levonorgestrel intrauterine system 52 mg (Mirena (R)) for 7 years and the Multiload Cu-250 for 4 years. Women who are at least 35 years old at the time of insertion of a TCu380A IUD can continue use until menopause with a negligible risk of pregnancy. We found no data to support use of the LNG-IUS 13.5 mg (Skyla (R)) beyond 3 years. When counseling about extended IUD use, clinicians should consider patient characteristics and preferences, as well as country- and community-specific factors. Future research is necessary to determine the risk of pregnancy associated with extended use of the copper IUD and the LNG-IUS among nulliparous women and women less than 25 years old at the time of IUD insertion. More data are needed on the potential effect of overweight and obesity on the long-term efficacy of the LNG-IUS. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:495 / 503
页数:9
相关论文
共 53 条
[1]  
Ali MM., 2011, Long-term Contraceptive Protection, Discontinuation, and Switching Behavior: Intrauterine Device (IUD) use Dynamics in 14 Developing Countries
[2]   Reduction of the "burst release" of copper ions from copper-based intrauterine devices by organic inhibitors [J].
Alvarez, Florencia ;
Schilardi, Patricia L. ;
Lorenzo de Mele, Monica Fernandez .
CONTRACEPTION, 2012, 85 (01) :91-98
[3]   LEVONORGESTREL-RELEASING AND COPPER-RELEASING (NOVA T) IUDS DURING 5 YEARS OF USE - A RANDOMIZED COMPARATIVE TRIAL [J].
ANDERSSON, K ;
ODLIND, V ;
RYBO, G .
CONTRACEPTION, 1994, 49 (01) :56-72
[4]  
[Anonymous], 1987, World Health Organ Tech Rep Ser, V753, P1
[5]  
[Anonymous], 1994, Contraception, V49, P543
[6]  
[Anonymous], 2008, IMPROVING THE SAFETY, P20
[7]  
[Anonymous], 2003, REPRODUCTION ANNUAL, P59
[8]  
[Anonymous], 2013, HEALTHCARE PHARMACEU
[9]   Characterization of copper in uterine fluids of patients who use the copper T-380A intrauterine device [J].
Arancibia, V ;
Peña, C ;
Allen, HE ;
Lagos, G .
CLINICA CHIMICA ACTA, 2003, 332 (1-2) :69-78
[10]   TCu 380A IUD: a reversible permanent contraceptive method in women over 35 years of age [J].
Bahamondes, L ;
Faundes, A ;
Sobreira-Lima, B ;
Lui, JF ;
Pecci, P ;
Matera, S .
CONTRACEPTION, 2005, 72 (05) :337-341