Enhancing the thermal and economic performance of supercritical CO2 plant by waste heat recovery using an ejector refrigeration cycle

被引:47
作者
Mohammed, Ramy H. [1 ]
Qasem, Naef A. A. [2 ]
Zubair, Syed M. [3 ]
机构
[1] Zagazig Univ, Dept Mech Power Engn, Zagazig 44159, Egypt
[2] King Fahd Univ Petr & Minerals, Dept Aerosp Engn, Dhahran 31261, Saudi Arabia
[3] King Fahd Univ Petr & Minerals, Dept Mech Engn, Dhahran 31261, Saudi Arabia
关键词
Hybridization; Supercritical CO2; Ejector refrigeration; Sensitivity analysis; Economic analysis; Multi-objective optimization; POWER-GENERATION; EXERGY; OPTIMIZATION; WORKING; DESIGN; ENERGY; SYSTEM;
D O I
10.1016/j.enconman.2020.113340
中图分类号
O414.1 [热力学];
学科分类号
摘要
Supercritical CO2 cycle has an optimal performance when the cycle minimum temperature is around the critical temperature (31 degrees C), which is impossible at hot climatic conditions. To solve this problem, this work hybridizes a supercritical CO2 cycle with an ejector refrigeration cycle (ERC) to cool the minimum temperature of the cycle to be about 31 degrees C and hence achieving the highest possible performance. Comprehensive energy, exergy, and economic analyses are carried out to explore the mechanisms of performance improvement of the novel combined plant. Sensitivity analysis is performed to recognize the most influencing parameters on the performance of the combined plant. Based on the sensitivity analysis, the effect of different operating and design parameters on the system performance is investigated. Furthermore, a multi-objective optimization study is performed to find the trade-off between exergy efficiency and cost-saving. Among the different the five refrigerants used for ERC, the results illustrate that R717 is the most efficient one for the present hybridization. The exergy destruction in the precooler reduces from 15.5% to 0.7% when ERC is combined with the sCO(2) cycle. Thus, the energy efficiency (eta(th)) and exergy efficiency (eta(ex)) increase by 9.5%, while the levelized cost of energy (LCOE) declines by 10.7%. Compared with the standalone sCO(2) cycle, the produced power, eta(th), eta(ex), and LCOE of the optimized plant improve by 94.3%, 36.2%, 28.6%, and 18.3%, respectively.
引用
收藏
页数:15
相关论文
共 50 条
[31]   A partial heating supercritical CO2 nested transcritical CO2 cascade power cycle for marine engine waste heat recovery: Thermodynamic, economic, and footprint analysis [J].
Wang, Zhe ;
Jiang, Yuemao ;
Ma, Yue ;
Han, Fenghui ;
Ji, Yulong ;
Cai, Wenjian .
ENERGY, 2022, 261
[32]   Improvement design and analysis of a supercritical CO2/transcritical CO2 combined cycle for offshore gas turbine waste heat recovery [J].
Zhou, Aozheng ;
Li, Xue-song ;
Ren, Xiao-dong ;
Gu, Chun-wei .
ENERGY, 2020, 210
[33]   Performance analysis and optimization of cascade waste heat recovery system based on transcritical CO2 cycle for waste heat recovery in waste-to-energy plant [J].
Ni, Tianming ;
Si, Junwei ;
Lu, Fulu ;
Zhu, Yan ;
Pan, Mingzhang .
JOURNAL OF CLEANER PRODUCTION, 2022, 331
[34]   Thermoeconomic analysis of improved exhaust waste heat recovery system for natural gas engine based on Vortex Tube heat booster and supercritical CO2 Brayton cycle [J].
Maestre-Cambronel, Daniel ;
Barros, Joel Guzman ;
Gonzalez-Quiroga, Arturo ;
Bula, Antonio ;
Duarte-Forero, Jorge .
SUSTAINABLE ENERGY TECHNOLOGIES AND ASSESSMENTS, 2021, 47
[35]   Optimization analysis of Organic Rankine Cycle powered by waste heat of a supermarket transcritical CO2 multi-ejector refrigeration cycle [J].
Tsimpoukis, Dimitrios ;
Syngounas, Evangelos ;
Bellos, Evangelos ;
Koukou, Maria ;
Tzivanidis, Christos ;
Anagnostatos, Stavros ;
Vrachopoulos, Michail Gr .
JOURNAL OF CLEANER PRODUCTION, 2023, 418
[36]   THERMODYNAMIC ANALYSIS AND SYSTEM DESIGN OF THE SUPERCRITICAL CO2 BRAYTON CYCLE FOR WASTE HEAT RECOVERY OF GAS TURBINE [J].
Xie, Min ;
Xie, Yonghui ;
He, Yichuan ;
Dong, Aihua ;
Zhang, Chunwei ;
Shi, Yuwen ;
Zhang, Qiuhong ;
Yang, Qiguo .
HEAT TRANSFER RESEARCH, 2020, 51 (02) :129-146
[37]   Genetic algorithm-based optimization of combined supercritical CO2 power and flash-tank enhanced transcritical CO2 refrigeration cycle for shipboard waste heat recuperation [J].
Nanzeeba, Fairooz ;
Baigh, Tajwar A. ;
Kabir, Afrida ;
Khan, Yasin ;
Ehsan, M. Monjurul .
ENERGY REPORTS, 2024, 12 :1810-1835
[38]   Calculation and analysis on transcritical ejector refrigeration cycle with CO2 [J].
Wang, Fei ;
Yang, Yong ;
Shen, Shengqiang .
Huagong Xuebao/CIESC Journal, 2013, 64 (07) :2400-2404
[39]   Experimental investigation of ejector performance and transcritical CO2 dual-evaporator ejector expansion refrigeration cycle performance [J].
Fan, Mingjing ;
Wu, Aihua ;
Wang, Zihang ;
Wang, Fei ;
Zhu, Wanpeng ;
Wang, Xingmin ;
He, Guogeng .
APPLIED THERMAL ENGINEERING, 2025, 274
[40]   Parametric Study of a Supercritical CO2 Power Cycle for Waste Heat Recovery with Variation in Cold Temperature and Heat Source Temperature [J].
Kim, Young-Min ;
Lee, Young-Duk ;
Ahn, Kook-Young .
ENERGIES, 2021, 14 (20)