摘要
The number of presbyopia correcting intraocular lenses (IOLs) is increasing and new technologies are constantly emerging with the aim of correcting the loss of accommodation after cataract surgery. Various optical designs have been proposed to implement multifocality or an extended depth of focus (EDOF). Depending on the optical principle of an implanted lens, the visual performance often is deteriorated by superposition of individual image planes and halos of varying intensity. This experimental study presents a concept to visualize the light fields and especially the halos of mono- and multifocal IOLs using the well known alcoholic beverage "ouzo" in order to obtain qualitative data on the imaging characteristics. We conclude that ouzo is a useful, cost effective, and nonpolluting medium for beam visualization and an alternative to fluorescein or milk, which could find an application for educational purposes.
引用
收藏
页数:10
相关论文
共 42 条
  • [1] Alba-Bueno F, 2014, Arch Soc Esp Oftalmol, V89, P397, DOI 10.1016/j.oftal.2014.01.002
  • [2] Contrast sensitivity with bifocal intraocular lenses is halved, as measured with the Freiburg Vision Test (FrACT), yet patients are happy
    Anton, Alexandra
    Boehringer, Daniel
    Bach, Michael
    Reinhard, Thomas
    Birnbaum, Florian
    [J]. GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2014, 252 (03) : 539 - 544
  • [3] Image quality with multifocal intraocular lenses and the effect of pupil size -: Comparison of refractive and hybrid refractive-diffractive designs
    Artigas, Jose M.
    Menezo, Jose L.
    Peris, Cristina
    Felipe, Adelina
    Diaz-Llopis, Manuel
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2007, 33 (12) : 2111 - 2117
  • [4] A New Extended Depth of Focus Intraocular Lens Based on Spherical Aberration
    Bellucci, Roberto
    Curatolo, Maria C.
    [J]. JOURNAL OF REFRACTIVE SURGERY, 2017, 33 (06) : 389 - +
  • [5] Breyer DRH, 2017, ASIA-PAC J OPHTHALMO, V6, P339, DOI 10.22608/APO.2017186
  • [6] Assessment of dysphotopsia in pseudophakic subjects with multifocal intraocular lenses
    Buckhurst, Phillip J.
    Naroo, Shehzad A.
    Davies, Leon N.
    Shah, Sunil
    Drew, Tom
    Wolffsohn, James S.
    [J]. BMJ OPEN OPHTHALMOLOGY, 2016, 1 (01):
  • [7] Optical bench performance of AcrySof((R)) IQ ReSTOR (R), AT LISA((R)) tri, and FineVision((R)) intraocular lenses
    Carson, Daniel
    Hill, Warren E.
    Hong, Xin
    Karakelle, Mutlu
    [J]. CLINICAL OPHTHALMOLOGY, 2014, 8 : 2105 - 2113
  • [8] Effect of position of near addition in an asymmetric refractive multifocal intraocular lens on quality of vision
    de Wit, Deric W.
    Diaz, Jose
    Moore, Tara C. B.
    Moutari, Salissou
    Moore, Jonathan E.
    [J]. JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2015, 41 (05) : 945 - 955
  • [9] dukus, 2018, DIGICAMCONTROL FREE
  • [10] OPTICAL-PERFORMANCE OF BIFOCAL AND MULTIFOCAL INTRAOCULAR LENSES TESTED WITH A NEW DEVICE
    EISENMANN, D
    JACOBI, KW
    REINER, J
    [J]. KLINISCHE MONATSBLATTER FUR AUGENHEILKUNDE, 1992, 201 (06) : 381 - 387