Building Multidevice Pipeline Constructs of Favorable Metal Coverage: A Practical Guide

被引:51
作者
Shapiro, M. [1 ,2 ]
Raz, E. [1 ]
Becske, T. [1 ,2 ]
Nelson, P. K. [1 ,3 ]
机构
[1] NYU, Dept Radiol, Bernard & Irene Schwartz Neurointervent Radiol Se, Langone Med Ctr, New York, NY 10016 USA
[2] NYU, Dept Neurol, Langone Med Ctr, New York, NY 10016 USA
[3] NYU, Dept Neurosurg, Langone Med Ctr, New York, NY 10016 USA
关键词
EMBOLIZATION DEVICE; FLOW DIVERTORS; IN-VIVO; ANEURYSMS; POROSITY; STENTS; TRIAL; NECK;
D O I
10.3174/ajnr.A3902
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
BACKGROUND AND PURPOSE: The advent of low-porosity endoluminal devices, also known as flow diverters, exemplified by the Pipeline in the United States, produced the greatest paradigm shift in cerebral aneurysm treatment since the introduction of detachable coils. Despite robust evidence of efficacy and safety, key questions regarding the manner Of their use remain unanswered. Recent studies demonstrated that the Pipeline device geometry can dramatically affect its metal coverage, emphasizing the negative effects of oversizing the device relative to its target vessels. This follow-up investigation focuses on the geometry and coverage of multidevice constructs. MATERIALS AND METHODS: A number of Pipeline devices were deployed in tubes of known diameters and photographed, and the resultant coverage was determined by image segmentation. Multidevice segmentation images were created to study the effects of telescoped devices and provide an estimate of coverages resulting from device overlap. RESULTS: Double overlap yields a range of metal coverage, rather than a single value, determined by the diameters of both devices, the size of the recipient artery, and the degree to which strands of the overlapped devices are coregistered with each other. The potential variation in coverage is greatest during overlap of identical-diameter devices, for example, ranging from 24% to 41% for two 3.75-mm devices deployed in a 3.5-mm vessel. Overlapping devices of progressively different diameters produce correspondingly more uniform ranges of coverage, though reducing the maximum achievable value, for example, yielding a 33%-34% range for 3.75- and 4.75-mm devices deployed in the same 3.5-mm vessel. CONCLUSIONS: Rational strategies for building multidevice constructs can achieve favorable geometric outcomes.
引用
收藏
页码:1556 / 1561
页数:6
相关论文
共 13 条
[1]   An in vitro study of silk stent morphology [J].
Aurboonyawat, Thaweesak ;
Blanc, Raphael ;
Schmidt, Paul ;
Piotin, Michel ;
Spelle, Laurent ;
Nakib, Amir ;
Moret, Jacques .
NEURORADIOLOGY, 2011, 53 (09) :659-667
[2]   Pipeline for Uncoilable or Failed Aneurysms: Results from a Multicenter Clinical Trial [J].
Becske, Tibor ;
Kallmes, David F. ;
Saatci, Isil ;
McDougall, Cameron G. ;
Szikora, Istvn ;
Lanzino, Giuseppe ;
Moran, Christopher J. ;
Woo, Henry H. ;
Lopes, Demetrius K. ;
Berez, Aaron L. ;
Cher, Daniel J. ;
Siddiqui, Adnan H. ;
Levy, Elad I. ;
Albuquerque, Felipe C. ;
Fiorella, David J. ;
Berentei, Zsolt ;
Marosfoi, Miklos ;
Cekirge, Saruhan H. ;
Nelson, Peter K. .
RADIOLOGY, 2013, 267 (03) :858-868
[3]   Stents and flow diverters in the treatment of aneurysms: device deformation in vivo may alter porosity and impact efficacy [J].
Bing, Fabrice ;
Darsaut, Tim E. ;
Salazkin, Igor ;
Makoyeva, Alina ;
Gevry, Guylaine ;
Raymond, Jean .
NEURORADIOLOGY, 2013, 55 (01) :85-92
[4]   Patency of Branches after Coverage with Multiple Telescoping Flow-Diverter Devices: An In Vivo Study in Rabbits [J].
Dai, D. ;
Ding, Y. H. ;
Kadirvel, R. ;
Rad, A. E. ;
Lewis, D. A. ;
Kallmes, D. F. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (01) :171-174
[5]  
Kallmes D, 2013, P 10 ANN M SOC NEUR
[6]   Endoluminal Scaffolds for Vascular Reconstruction and Exclusion of Aneurysms From the Cerebral Circulation [J].
Lieber, Baruch B. ;
Sadasivan, Chander .
STROKE, 2010, 41 (10) :S21-S25
[7]   The Varying Porosity of Braided Self-Expanding Stents and Flow Diverters: An Experimental Study [J].
Makoyeva, A. ;
Bing, F. ;
Darsaut, T. E. ;
Salazkin, I. ;
Raymond, J. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2013, 34 (03) :596-602
[8]  
Molyneux A, 2013, P 51 ANN M AM SOC NE, P570
[9]   Effects of Flow-Diverting Device Oversizing on Hemodynamics Alteration in Cerebral Aneurysms [J].
Mut, F. ;
Cebral, J. R. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2012, 33 (10) :2010-2016
[10]   The Pipeline Embolization Device for the Intracranial Treatment of Aneurysms Trial [J].
Nelson, P. K. ;
Lylyk, P. ;
Szikora, I. ;
Wetzel, S. G. ;
Wanke, I. ;
Fiorella, D. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :34-40