Investigation of powder dispersion inside a SPIROS® dry dry powder inhaler using particle image velocimetry

被引:18
作者
Han, R
Papadopoulos, G
Greenspan, BJ
机构
[1] Dura Pharmaceut, San Diego, CA 92121 USA
[2] Dantec Dynam Inc, Mahwah, NJ 07430 USA
关键词
dry powder inhaler; dispersion; particle image velocimetry; impaction; velocity; particle differentiation;
D O I
10.1016/S0032-5910(01)00515-0
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Flow field distributions and drug dispersion inside the mouthpiece of a Spiros((R)) inhaler, a dry powder inhaler (DPI) delivering therapeutic powders to airways, were investigated by means of the particle image velocimetry (PIV) technique. The aim of the study was to obtain flow patterns inside the mouthpiece during a typical inhalation cycle, and to gain insight on the powder dispersion mechanism inside the aerosolization chamber. Air stream velocities inside the mouthpiece were determined from correlated image-pairs of smoke particles, introduced around the modeled inhaler and drawn into the mouthpiece. On the other hand, to investigate the dispersion mechanism, lactose particles (the excipient) were replaced by fluorescent particles that bad a similar mean aerodynamic diameter, so that differentiation from the Mie scattering signal of the drug particles could be made by using high-pass and band-pass color filters. The two emissions were simultaneous recorded using a pair of digital cameras, and the dispersion of each was recorded at various normal planes within the mouthpiece. Experimental results showed that rotational turbulent flow prevailed in the downstream sections of the mouthpiece. Impaction seemed to be the dominant dispersion mechanism in the modeled inhaler and the respirable fraction of drug particles was released from the dispersion chamber within the first 2 s of operation. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:266 / 278
页数:13
相关论文
共 14 条
[1]  
ARIK EB, 1996, ICIASF, V17, P267
[2]   DRY POWDER AEROSOLS .1. NEW POWDER INHALATION DEVICE [J].
BELL, JH ;
HARTLEY, PS ;
COX, JSG .
JOURNAL OF PHARMACEUTICAL SCIENCES, 1971, 60 (10) :1559-&
[3]   LUNG DEPOSITION OF BUDESONIDE INHALED VIA TURBUHALER(R) - A COMPARISON WITH TERBUTALINE SULFATE IN NORMAL SUBJECTS [J].
BORGSTROM, L ;
BONDESSON, E ;
MOREN, F ;
TROFAST, E ;
NEWMAN, SP .
EUROPEAN RESPIRATORY JOURNAL, 1994, 7 (01) :69-73
[4]   Influence of particle size, air flow, and inhaler device on the dispersion of mannitol powders as aerosols [J].
Chew, NYK ;
Chan, HK .
PHARMACEUTICAL RESEARCH, 1999, 16 (07) :1098-1103
[5]  
Concessio N.M., 1998, RESP DRUG DELIVERY, VVI, P251
[6]  
Endo Y, 1997, POWDER TECHNOL, V91, P25
[7]   The influence of formulation on emission, deaggregation and deposition of dry powders for inhalation [J].
French, DL ;
Edwards, DA ;
Niven, RW .
JOURNAL OF AEROSOL SCIENCE, 1996, 27 (05) :769-783
[8]  
HAN R, 2002, AEROSOL SCI TECHNOLO, V36, P5
[9]  
Host-Madsen A., 1994, 7 INT S APPL LAS TEC
[10]   DISPERSION MECHANISM OF AGGREGATE PARTICLES IN AIR [J].
KOUSAKA, Y ;
OKUYAMA, K ;
SHIMIZU, A ;
YOSHIDA, T .
JOURNAL OF CHEMICAL ENGINEERING OF JAPAN, 1979, 12 (02) :152-159