Development of a rapid method for the analysis of synthetic growth promoters in bovine muscle using liquid chromatography tandem mass spectrometry

被引:35
作者
Malone, E. M. [1 ,2 ]
Elliott, C. T. [2 ]
Kennedy, D. G. [3 ]
Regan, L. [1 ]
机构
[1] State Lab, Celbridge, Co Kildare, Ireland
[2] Queens Univ Belfast, Sch Biol Sci, Belfast, Antrim, North Ireland
[3] Agrifood & Biosci Inst, Belfast, Antrim, North Ireland
关键词
Growth promoters; Method validation; Mass spectrometry; Bovine muscle; Analysis; ANABOLIC-STEROIDS RESIDUES; SOLID-PHASE EXTRACTION; KIDNEY FAT; URINE SAMPLES; MEAT; HORMONES; TISSUES; PLASMA; IMMUNOASSAYS; GESTAGENS;
D O I
10.1016/j.aca.2008.09.002
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A rapid liquid chromatography tandem mass spectrometry (LC-MS/MS) method has been developed and validated for the simultaneous identification, confirmation and quantitation of thirteen synthetic growth promoters in bovine muscle. The method was validated in accordance with the criteria defined in Commission Decision 2002/657/EC. A value of 1 mu g kg(-1) was chosen as the required performance level (RPL) for all analytes. The growth promoters investigated were a and p trenbolone, 16-beta-OH stanozolol, methylboldenone, fluoxymesterone, methyltestosterone, medroxyprogesterone acetate, megestrol acetate, melengestrol acetate, dexamethasone, flumethasone, dienestrol and hexestrol. The method involved enzymatic hydrolysis, purification by solid phase extraction followed by analysis by UPLC-MS/MS using electrospray ionization operated in both positive and negative polarities with a total run time of 14 min. The decision limit (CC alpha) values obtained, ranged from 0.09 to 0.19 mu g kg(-1) and the detection capability (CC beta) values obtained, ranged from 0.15 to 0.32 mu g kg(-1). The results of the inter-assay study, which was performed by fortifying bovine muscle samples (n = 18) on three separate days, show the accuracy calculated for the various analytes to range between 98% and 102%. The precision of the method, expressed as R.S.D. values for the inter-assay variation of each analyte at the three levels of fortification (1, 1.5 and 2.0 mu g kg(-1)), ranged between 3.1% and 5.8%. A Day 4 assay was carried out to examine variations due to different animals and different muscle types. (c) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:112 / 120
页数:9
相关论文
共 31 条
[1]   Comparison of conventional immunoassays and the oestrogen radioreceptor assay for screening for the presence of oestrogenic anabolic compounds in urine samples [J].
Arts, CJM ;
van Baak, MJ ;
Elliot, CJ ;
Hewitt, SA ;
Cooper, J ;
van de Velde-Fase, K ;
Witkamp, RF .
ANALYST, 1998, 123 (12) :2579-2583
[2]   Analysis of meat samples for anabolic steroids residues by liquid chromatography/tandem mass spectrometry [J].
Blasco, Cristina ;
Van Poucke, Christof ;
Van Peteghem, Carlos .
JOURNAL OF CHROMATOGRAPHY A, 2007, 1154 (1-2) :230-239
[3]   Simultaneous determination, in calf urine, of twelve anabolic agents as heptafluorobutyryl derivatives by capillary gas chromatography mass spectrometry [J].
Casademont, G ;
Perez, B ;
Regueiro, JAG .
JOURNAL OF CHROMATOGRAPHY B-BIOMEDICAL APPLICATIONS, 1996, 686 (02) :189-198
[4]   Validation of multi-residue methods for the detection of anabolic steroids by GC-MS in muscle tissues and urine samples from cattle [J].
Daeseleire, E ;
Vandeputte, R ;
Van Peteghem, C .
ANALYST, 1998, 123 (12) :2595-2598
[5]   THE ANALYSIS OF TRENBOLONE AND THE HUMAN URINARY METABOLITES OF TRENBOLONE ACETATE BY GAS-CHROMATOGRAPHY MASS-SPECTROMETRY AND GAS-CHROMATOGRAPHY TANDEM MASS-SPECTROMETRY [J].
DEBOER, D ;
BERNAL, MEG ;
VANOOYEN, RD ;
MAES, RAA .
BIOLOGICAL MASS SPECTROMETRY, 1991, 20 (08) :459-466
[6]   DETERMINATION OF THE CONCENTRATIONS OF THE STEROIDS ESTRADIOL, PROGESTERONE AND TESTOSTERONE IN BOVINE SERA - COMPARISON OF COMMERCIAL DISSOCIATION ENHANCED LANTHANIDE FLUORESCENCE IMMUNOASSAY KITS WITH CONVENTIONAL RADIO AND ENZYME IMMUNOASSAYS [J].
ELLIOTT, CT ;
FRANCIS, KS ;
SHORTT, HD ;
MCCAUGHEY, WJ .
ANALYST, 1995, 120 (06) :1827-1830
[7]  
*EUR, 2005, EU 15 EU N10 MAIN MA
[8]   The appraisal of an automated multi-immunoaffinity chromatography system to detect anabolic agents in bile and urine [J].
Fodey, TL ;
Elliott, CT ;
Crooks, SRH ;
McCaughey, WJ .
FOOD AND AGRICULTURAL IMMUNOLOGY, 1996, 8 (03) :157-167
[9]   Determination of residual anabolic steroid in meat by gas chromatography-ion trap-mass spectrometer [J].
Fuh, MR ;
Huang, SY ;
Lin, TY .
TALANTA, 2004, 64 (02) :408-414
[10]   Evaluation of a solid-phase extraction procedure for the simultaneous determination of morphine, 6-monoacetylmorphine, codeine and dihydrocodeine in plasma and whole blood by GC/MS [J].
Geier, A ;
Bergemann, D ;
vonMeyer, L .
INTERNATIONAL JOURNAL OF LEGAL MEDICINE, 1996, 109 (02) :80-83