An overview of modified sensors with focus on electrochemical sensing of sulfite in food samples

被引:44
作者
Bijad, Majedeh [1 ]
Hojjati-Najafabadi, Akbar [2 ]
Asari-Bami, Hesam [3 ]
Habibzadeh, Sepideh [4 ]
Amini, Issa [4 ]
Fazeli, Farzaneh [5 ]
机构
[1] Islamic Azad Univ, Dept Food Sci & Technol, Ayatollah Amoli Branch, Amol, Iran
[2] Jiangxi Univ Sci & Technol, Fac Mat Met & Chem, Sch Mat Sci & Engn, Ganzhou 341000, Peoples R China
[3] Islamic Azad Univ, Dept Chem, Sci & Res Branch, Mazandaran, Iran
[4] Payame Noor Univ, Dept Chem, POB 19395-4697, Tehran, Iran
[5] Payame Noor Univ, Dept Biol, POB 19395-4697, Tehran, Iran
来源
EURASIAN CHEMICAL COMMUNICATIONS | 2021年 / 3卷 / 02期
关键词
Sulfite analysis; modified electrodes; voltammetry; electrochemical sensors; amperometry; portable kits; CARBON-PASTE ELECTRODE; SCREEN-PRINTED ELECTRODE; PENCIL-GRAPHITE ELECTRODE; TEMPERATURE IONIC LIQUID; REDUCED GRAPHENE OXIDE; NICOTINAMIDE ADENINE-DINUCLEOTIDE; SENSITIVE VOLTAMMETRIC SENSOR; ANTICANCER DRUG 5-FLUOROURACIL; HEAVY-METAL IONS; GLASSY-CARBON;
D O I
10.22034/ecc.2021.268819.1122
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Sulfite is used as preservatives to slow browning and discoloration in foods and beverages during preparation, storage and distribution. In various pharmaceutical and food industries, sulfite is utilized for inhibition of nonenzymatic and enzymatic browning. Also, in brewing industries, it acts as an antioxidizing and antibacterial agent. Several toxic and adverse reactions, including vitamin deficiency, hypersensitivity, and allergic diseases have been attributed to sulfites ingestion that may cause dysbiotic oral and gut microbiota events. Thus, the content of sulfite in foods must be controlled and monitored, and it is essential to find a specific, reproducible, and sensitive method to detect sulfite. Some analytical solutions are being tested to quantify sulfite. However, due to their advantage over traditional techniques, electroanalytical techniques are attracting much attention, because they are simple, fast, affordable, and sensitive to implement. In addition, modifying the electrodes controls the morphology and size that results in the miniaturization to be used in portable electro-chemical devices. Therefore, the present review addressed some articles on the electro oxidation of sulfite from the real samples with the use of various kinds of electro-chemical sensors.
引用
收藏
页码:116 / 138
页数:23
相关论文
共 406 条
  • [31] Electrochemical determination of vitamin C in the presence of NADH using a CdO nanoparticle/ionic liquid modified carbon paste electrode as a sensor
    Arabali, Vahid
    Ebrahimi, Mahmoud
    Abbasghorbani, Maryam
    Gupta, Vinod Kumar
    Farsi, Mohammad
    Ganjali, M. R.
    Karimi, Fatemeh
    [J]. JOURNAL OF MOLECULAR LIQUIDS, 2016, 213 : 312 - 316
  • [32] A review on the applications of ultrasonic technology in membrane bioreactors
    Arefi-Oskoui, Samira
    Khataee, Alireza
    Safarpour, Mandie
    Orooji, Yasin
    Vatanpour, Vahid
    [J]. ULTRASONICS SONOCHEMISTRY, 2019, 58
  • [33] Oxidation of ethylbenzene using some recyclable cobalt nanocatalysts: The role of linker and electrochemical study
    Arshadi, M.
    Ghiaci, M.
    Ensafi, A. A.
    Karimi-Maleh, H.
    Suib, Steven L.
    [J]. JOURNAL OF MOLECULAR CATALYSIS A-CHEMICAL, 2011, 338 (1-2) : 71 - 83
  • [34] Ultrasonication-aided synthesis of nanoplates-like iron molybdate: Fabricated over glassy carbon electrode as an modified electrode for the selective determination of first generation antihistamine drug promethazine hydrochloride
    Arumugam, Balamurugan
    Muthukutty, Balamurugan
    Chen, Shen-Ming
    Ramaraj, Sayee Kannan
    Kumar, Jeyaraj Vinoth
    Nagarajan, E. R.
    [J]. ULTRASONICS SONOCHEMISTRY, 2020, 66
  • [35] MWCNTs/Cu(OH)2 nanoparticles/IL nanocomposite modified glassy carbon electrode as a voltammetric sensor for determination of the non-steroidal anti-inflammatory drug diclofenac
    Arvand, Majid
    Gholizadeh, Tahereh M.
    Zanjanchi, Mohammad Ali
    [J]. MATERIALS SCIENCE & ENGINEERING C-MATERIALS FOR BIOLOGICAL APPLICATIONS, 2012, 32 (06): : 1682 - 1689
  • [36] Glucose Oxidase/Nano-ZnO/Thin Film Deposit FTO as an Innovative Clinical Transducer: A Sensitive Glucose Biosensor
    Asrami, Padideh Naderi
    Azar, Parviz Aberoomand
    Tehrani, Mohammad Saber
    Mozaffari, Sayed Ahmad
    [J]. FRONTIERS IN CHEMISTRY, 2020, 8
  • [37] A novel impedimetric glucose biosensor based on immobilized glucose oxidase on a CuO-Chitosan nanobiocomposite modified FTO electrode
    Asrami, Padideh Naderi
    Mozaffari, Sayed Ahmad
    Tehrani, Mohammad Saber
    Azar, Parviz Aberoomand
    [J]. INTERNATIONAL JOURNAL OF BIOLOGICAL MACROMOLECULES, 2018, 118 : 649 - 660
  • [38] Impedimetric glucose biosensor based on nanostructure nickel oxide transducer fabricated by reactive RF magnetron sputtering system
    Asrami, Padideh Naderi
    Tehrani, Mohammad Saber
    Azar, Parviz Aberoomand
    Mozaffari, Sayed Ahmad
    [J]. JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2017, 801 : 258 - 266
  • [39] Host Guest Inclusion Complex Modified Electrode for the Sensitive Determination of a Muscle Relaxant Drug
    Atta, Nada F.
    Elkholy, Said S.
    Ahmed, Yousef M.
    Galal, Ahmed
    [J]. JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2016, 163 (07) : B403 - B409
  • [40] Gold Nanoparticles Modified Electrode for the Determination of an Antihypertensive Drug
    Atta, Nada F.
    Galal, Ahmed
    Azab, Shereen M.
    [J]. ELECTROANALYSIS, 2012, 24 (06) : 1431 - 1440