Most probable number - loop mediated isothermal amplification (MPN-LAMP) for quantifying waterborne pathogens in <25 min

被引:26
作者
Ahmad, Farhan [1 ]
Stedtfeld, Robert D. [1 ]
Waseem, Hassan [1 ]
Williams, Maggie R. [1 ]
Cupples, Alison M. [1 ]
Tiedje, James M. [2 ,3 ]
Hashsham, Syed A. [1 ,2 ]
机构
[1] Michigan State Univ, Dept Civil & Environm Engn, E Lansing, MI 48824 USA
[2] Michigan State Univ, Ctr Microbial Ecol, E Lansing, MI 48824 USA
[3] Michigan State Univ, Dept Microbiol & Mol Genet, E Lansing, MI 48824 USA
关键词
Loop-mediated isothermal amplification; Most probable number; Propidium monoazide; Detection limit; Point-of-care diagnostics; PROPIDIUM MONOAZIDE; DNA AMPLIFICATION; ETHIDIUM MONOAZIDE; MICROFLUIDIC CHIP; PCR; CELLS; ENUMERATION; BACTERIA; BLOOD; POINT;
D O I
10.1016/j.mimet.2016.11.010
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
We are reporting a most probable number approach integrated to loop mediated isothermal technique (MPN-LAMP) focusing on Gram-negative Escherichia coli and Gram-positive Enterococcus faecalis bacterial cells without nucleic acids extraction. LAMP assays for uidA from E. coli and gelE from E. faecalis were successfully performed directly on cells up to single digit concentration using a commercial real time PCR instrument. Threshold time values of LAMP assays of bacterial cells, heat treated bacterial cells (95 degrees C for 5 min), and their purified genomic DNA templates were similar, implying that amplification could be achieved directly from bacterial cells at 63 degrees C. Viability of bacterial cells was confirmed by using propidium monoazide in a LAMP assay with E. faecalis. To check its functionality on a microfluidic platform, MPN-LAMP assays targeting <10 CFU of bacteria were also translated onto polymeric microchips and monitored by a low-cost fluorescence imaging system. The overall system provided signal-to-noise (SNR) ratios up to 800, analytical sensitivity of <10 CFU, and time to positivity of about 20 min. MPN-LAMP assays were performed for cell concentrations in the range of 105 CFU to <10 CFU. MPN values from LAMP assays confirmed that the amplifications were from <10 CFU. The method described here, applicable directly on cells at 63 degrees C, eliminates the requirement of complex nucleic acids extraction steps, facilitating the development of sensitive, rapid, low-cost, and field-deployable systems. This rapid MPN-LAMP approach has the potential to replace conventional MPN method for waterborne pathogens. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:27 / 33
页数:7
相关论文
共 54 条
  • [1] Abu Al-Soud W, 1998, APPL ENVIRON MICROB, V64, P3748
  • [2] Quantification of viable Legionella pneumophila cells using propidium monoazide combined with quantitative PCR
    Adela Yanez, M.
    Nocker, Andreas
    Soria-Soria, Elena
    Murtula, Raquel
    Martinez, Lorena
    Catalan, Vicente
    [J]. JOURNAL OF MICROBIOLOGICAL METHODS, 2011, 85 (02) : 124 - 130
  • [3] A CCD-based fluorescence imaging system for real-time loop-mediated isothermal amplification-based rapid and sensitive detection of waterborne pathogens on microchips
    Ahmad, Farhan
    Seyrig, Gregoire
    Tourlousse, Dieter M.
    Stedtfeld, Robert D.
    Tiedje, James M.
    Hashsham, Syed A.
    [J]. BIOMEDICAL MICRODEVICES, 2011, 13 (05) : 929 - 937
  • [4] In-Gel Technology for PCR Genotyping and Pathogen Detection
    Atrazhev, Alexey
    Manage, Dammika P.
    Stickel, Alexander J.
    Crabtree, H. John
    Pilarski, Linda M.
    Acker, Jason P.
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (19) : 8079 - 8087
  • [5] Baatout S, 2005, ANN MICROBIOL, V55, P73
  • [6] Development of a loop-mediated isothermal amplification assay for the detection of Streptococcus agalactiae in bovine milk
    Bosward, Katrina L.
    House, John K.
    Deveridge, Amber
    Mathews, Karen
    Sheehy, Paul A.
    [J]. JOURNAL OF DAIRY SCIENCE, 2016, 99 (03) : 2142 - 2150
  • [7] Cryptosporidium Propidium Monoazide-PCR, a Molecular Biology-Based Technique for Genotyping of Viable Cryptosporidium Oocysts
    Brescia, Cristin C.
    Griffin, Shannon M.
    Ware, Michael W.
    Varughese, Eunice A.
    Egorov, Andrey I.
    Villegas, Eric N.
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2009, 75 (21) : 6856 - 6863
  • [8] Current techniques for single-cell lysis
    Brown, Robert B.
    Audet, Julie
    [J]. JOURNAL OF THE ROYAL SOCIETY INTERFACE, 2008, 5 (SUPPL.2) : S131 - S138
  • [9] Rapid Detection of Viable Salmonellae in Produce by Coupling Propidium Monoazide with Loop-Mediated Isothermal Amplification
    Chen, Siyi
    Wang, Fei
    Beaulieu, John C.
    Stein, Rebecca E.
    Ge, Beilei
    [J]. APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 2011, 77 (12) : 4008 - 4016
  • [10] Development of a toxR-based loop-mediated isothermal amplification assay for detecting Vibrio parahaemolyticus
    Chen, Siyi
    Ge, Beilei
    [J]. BMC MICROBIOLOGY, 2010, 10