High-performance non-enzymatic glucose sensor based on nickel-microcrystalline graphite-boron doped diamond complex electrode

被引:70
作者
Deng, Zejun [1 ]
Long, Hangyu [1 ,2 ]
Wei, Qiuping [1 ,2 ]
Yu, Zhiming [1 ,2 ]
Zhou, Bo [1 ]
Wang, Yijia [1 ]
Zhang, Long [2 ]
Li, Shasha [1 ]
Ma, Li [2 ]
Xie, Youneng [1 ]
Min, Jie [1 ]
机构
[1] Cent S Univ, Sch Mat Sci & Engn, Changsha 410083, Hunan, Peoples R China
[2] Cent S Univ, State Key Lab Powder Met, Changsha 410083, Hunan, Peoples R China
关键词
Non-enzymatic glucose sensor; Microcrystalline graphite; Boron doped diamond; Thermal catalytic etching; WALLED CARBON NANOTUBES; GRAPHENE OXIDE-FILM; NANOPARTICLES; BIOSENSOR; COMPOSITE; NI; DEPOSITION; NANOWIRES;
D O I
10.1016/j.snb.2016.09.176
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A nickel-microcrystalline graphite-boron doped diamond (Ni-MG-BDD) complex electrode was fabricated by thermal catalytic etching BDD film with Ni layer. Scanning electron microscopy, energy dispersive X-ray spectrum and Raman spectroscopy were utilized to characterize the morphology, composition of the complex electrode, respectively. Nickel particles with different sizes are demonstrated to sink into the crystal facet and grain boundary of the BDD film, which not only increases the specific surface area and the electrochemical stability of the electrode, but also catalyzes spa-bonded diamond into sp2-bonded microcrystalline graphitic carbon in the cooling process. The presence of microcrystalline graphite mixed with diamond film is confirmed to increase the conductivity of the electrode. Electrochemical results indicate that the Ni-MG-BDD complex electrode shows excellent electrochemical performance for glucose oxidation. The proposed electrode shows wide linear ranges for glucose concentrations of 0.002-0.5 and 0.5-15.5 mM with high sensitivities of 1010.8 and 660.81 mu AmM-1 cm(-2), respectively. In addition, the electrode exhibits a low detection limit of 0.24 mu M (S/N = 3), good selectivity and reproducibility, and excellent stability during the long-term electrochemical detection. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:825 / 834
页数:10
相关论文
共 49 条
[1]   Investigating pipeline and state of the art blood glucose biosensors to formulate next steps [J].
Aggidis, Anthony G. A. ;
Newman, Jeffrey D. ;
Aggidis, George A. .
BIOSENSORS & BIOELECTRONICS, 2015, 74 :243-262
[2]   On the reaction kinetics of Ni with amorphous carbon [J].
Anton, R. .
CARBON, 2008, 46 (04) :656-662
[3]   Carbohydrates electrocatalytic oxidation using CNT-NiCo-oxide modified electrodes [J].
Arvinte, Adina ;
Sesay, Adama-Marie ;
Virtanen, Vesa .
TALANTA, 2011, 84 (01) :180-186
[4]   Synthesis of carbon nanotube-nickel nanocomposites using atomic layer deposition for high-performance non-enzymatic glucose sensing [J].
Choi, Taejin ;
Kim, Soo Hyeon ;
Lee, Chang Wan ;
Kim, Hangil ;
Choi, Sang-Kyung ;
Kim, Soo-Hyun ;
Kim, Eunkyoung ;
Park, Jusang ;
Kim, Hyungjun .
BIOSENSORS & BIOELECTRONICS, 2015, 63 :325-330
[5]   A nonenzymatic glucose sensor using nanoporous platinum electrodes prepared by electrochemical alloying/dealloying in a water-insensitive zinc chloride-1-ethyl-3-methylimidazolium chloride ionic liquid [J].
Chou, Chih-Hung ;
Chen, Jyh-Cheng ;
Tai, Chia-Cheng ;
Sun, I-Wen ;
Zen, Jyh-Myng .
ELECTROANALYSIS, 2008, 20 (07) :771-775
[6]   Characterization of amorphous and nanocrystalline carbon films [J].
Chu, PK ;
Li, LH .
MATERIALS CHEMISTRY AND PHYSICS, 2006, 96 (2-3) :253-277
[7]   Fabrication of Nickel/nanodiamond/boron-doped diamond electrode for non-enzymatic glucose biosensor [J].
Dai, Wei ;
Li, Mingji ;
Gao, Sumei ;
Li, Hongji ;
Li, Cuiping ;
Xu, Sheng ;
Wu, Xiaoguo ;
Yang, Baohe .
ELECTROCHIMICA ACTA, 2016, 187 :413-421
[8]   Amperometric biosensor based on nanoporous nickel/boron-doped diamond film for electroanalysis of L-alanine [J].
Dai, Wei ;
Li, Mingji ;
Li, Hongji ;
Yang, Baohe .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 201 :31-36
[9]   Electrospun Co3O4 nanofibers for sensitive and selective glucose detection [J].
Ding, Yu ;
Wang, Ying ;
Su, Liang ;
Bellagamba, Michael ;
Zhang, Heng ;
Lei, Yu .
BIOSENSORS & BIOELECTRONICS, 2010, 26 (02) :542-548
[10]   Development of Cu2O/Carbon Vulcan XC-72 as non-enzymatic sensor for glucose determination [J].
El Khatib, K. M. ;
Hameed, R. M. Abdel .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) :3542-3548