Different simplified simulation models of a Passive Downdraught Evaporative Cooling tower (PDEC) were compared by using experimental data. Among these, a series of tests on a Passive Downdraught Evaporative Cooling tower (PDEC) were carried out at the SyTIn (Systems for Technology Innovation) Laboratory of the Department of Architecture and Design, Politecnico di Torino. In addition, other monitored databases were taken from literature and used as input data for the simplified models. The collected inlet airflow data were used for calculating predicted outlet airflow values by using four equations and a software from literature. The comparison of those outlet airflow data allowed for assessing the effectiveness and the accuracy of the analysed simplified methods, which are also used for simulating the PDEC tower in several dynamic simulation software such as DesignBuilder coupled with EnergyPlus. The presented results could help designers in choosing amid different calculation models. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:263 / 272
页数:10
相关论文
共 58 条
  • [1] Acquiletti F., 2014, THESIS
  • [2] Alvarez S., 1997, International Journal of Solar Energy, V19, P179, DOI [10.1080/01425919708914336, DOI 10.1080/01425919708914336]
  • [3] [Anonymous], 2007, ADV PASSIVE COOLING
  • [4] [Anonymous], ENERGY EFFICIENCY CE
  • [5] [Anonymous], 2011, RAFFRESCAMENTO PASSI
  • [6] Comparison of solar radiation models and their validation under Algerian climate - The case of direct irradiance
    Behar, Omar
    Khellaf, Abdallah
    Mohammedi, Kama
    [J]. ENERGY CONVERSION AND MANAGEMENT, 2015, 98 : 236 - 251
  • [7] Assessment for buildings equipped with passive cooling systems. Application for the case of adiabatic evaporation.
    Belarbi, R
    Sperandio, M
    Allard, F
    [J]. REVUE GENERALE DE THERMIQUE, 1997, 36 (07): : 547 - 560
  • [8] Modeling of water spray evaporation: Application to passive cooling of buildings
    Belarbi, Rafik
    Ghiaus, Cristian
    Allard, Francis
    [J]. SOLAR ENERGY, 2006, 80 (12) : 1540 - 1552
  • [9] Bouchahm Y., 2008, P 25 PLEA C DUBL IRL, P5
  • [10] Application of passive downdraught evaporative cooling (PDEC) to non-domestic buildings
    Bowman, N
    Lomas, K
    Cook, M
    Eppel, H
    Ford, B
    Hewitt, M
    Cucinella, M
    Francis, E
    Rodriguez, E
    Gonzalez, R
    Alvarez, S
    Galata, A
    Lanarde, P
    Belarbi, R
    [J]. RENEWABLE ENERGY, 1997, 10 (2-3) : 191 - 196