Plasticized PVC Membrane Modified Electrodes: Voltammetry of Highly Hydrophobic Compounds

被引:11
作者
Lindner, Erno [1 ]
Guzinski, Marcin [2 ]
Pendley, Bradford [1 ]
Chaum, Edward [2 ]
机构
[1] Univ Memphis, Dept Biomed Engn, Memphis, TN 38152 USA
[2] Vanderbilt Univ, Med Ctr, Vanderbilt Eye Inst, Nashville, TN 37232 USA
关键词
chemically modified electrodes; membrane-coated voltammetric sensors; antidepressant and immunosuppressant drugs; detection limit; resolution; STRIPPING VOLTAMMETRY; DIFFUSION-COEFFICIENTS; ION; 2,6-DIISOPROPYLPHENOL; PROPOFOL; PITFALLS; SENSORS; WATER;
D O I
10.3390/membranes10090202
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
In the last 50 years, plasticized polyvinyl chloride (PVC) membranes have gained unique importance in chemical sensor development. Originally, these membranes separated two solutions in conventional ion-selective electrodes. Later, the same membranes were applied over a variety of supporting electrodes and used in both potentiometric and voltammetric measurements of ions and electrically charged molecules. The focus of this paper is to demonstrate the utility of the plasticized PVC membrane modified working electrode for the voltammetric measurement of highly lipophilic molecules. The plasticized PVC membrane prevents electrode fouling, extends the detection limit of the voltammetric methods to sub-micromolar concentrations, and minimizes interference by electrochemically active hydrophilic analytes.
引用
收藏
页码:1 / 17
页数:16
相关论文
共 42 条
  • [1] Theory and Experiments of Transport at Channel Microband Electrodes under Laminar Flows. 2. Electrochemical Regimes at Double Microband Assemblies under Steady State
    Amatore, Christian
    Da Mota, Nicolas
    Lemmer, Celia
    Pebay, Cecile
    Sella, Catherine
    Thouin, Laurent
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (24) : 9483 - 9490
  • [2] Voltammetry of the phase transfer of polypeptide protamines across polarized liquid/liquid interfaces
    Amemiya, S
    Yang, XT
    Wazenegger, TL
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2003, 125 (39) : 11832 - 11833
  • [3] Voltammetric Ion Selectivity of Thin Ionophore-Based Polymeric Membranes: Kinetic Effect of Ion Hydrophilicity
    Amemiya, Shigeru
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (17) : 8893 - 8901
  • [4] Electrochemical sensing and imaging based on ion transfer at liquid/liquid interfaces
    Amemiya, Shigeru
    Kim, Jiyeon
    Izadyar, Anahita
    Kabagambe, Benjamin
    Shen, Mei
    Ishimatsu, Ryoichi
    [J]. ELECTROCHIMICA ACTA, 2013, 110 : 836 - 845
  • [5] Electrochemical heparin sensing at liquid/liquid interfaces and polymeric membranes
    Amemiya, Shigeru
    Kim, Yushin
    Ishimatsu, Ryoichi
    Kabagambe, Benjamin
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2011, 399 (02) : 571 - 579
  • [6] [Anonymous], 2001, ORGANIC ELECTROCHEMI
  • [7] Chronopotentiometric method for the assessment of ionophore diffusion coefficients in solvent polymeric membranes
    Bodor, Sandor
    Zook, Justin M.
    Lindner, Erno
    Toth, Klara
    Gyurcsanyi, Robert E.
    [J]. JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (01) : 171 - 179
  • [8] Studies of potential generation across membrane sensors at interfaces and through bulk
    Buck, RP
    Lindner, E
    [J]. ACCOUNTS OF CHEMICAL RESEARCH, 1998, 31 (05) : 257 - 266
  • [9] COATED WIRE ION SELECTIVE ELECTRODES
    CATTRALL, RW
    FREISER, H
    [J]. ANALYTICAL CHEMISTRY, 1971, 43 (13) : 1905 - &
  • [10] Fibbioli M, 2000, ELECTROANAL, V12, P1286, DOI 10.1002/1521-4109(200011)12:16<1286::AID-ELAN1286>3.0.CO