RETRACTED: Superb microvascular imaging evaluating joint lesion scores in rheumatoid arthritis compared with power Doppler imaging A meta-analysis (Retracted article. See vol. 104, 2025)

被引:8
作者
Lin, MingXin [1 ]
Wang, Cong [1 ]
机构
[1] Dalian Med Univ, Ultrasound Dept, Affiliated Hosp 1, 222 Zhongshan Rd, Dalian 116011, Liaoning, Peoples R China
关键词
power Doppler imaging; rheumatoid arthritis; superb microvascular imaging; ULTRASOUND; SYNOVITIS;
D O I
10.1097/MD.0000000000022185
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: To compare superb microvascular imaging with power Doppler imaging for evaluating joint lesion scores in rheumatoid arthritis based on high quality clinical cohort or case control studies. Methods: We searched Medline (via PubMed), Web of Science, Cochrane Library, Embase, and Chinese Biomedical Literature Database without restrictions of language and publication status. Two investigators will identify relevant trials, extract data, and appraise risk of bias in each eligible trial. Data will be pooled by either a fixed-effects model or a random-effects model according to the results of heterogeneity identification. The primary outcomes include a semi-quantitative scoring system, through which synovial vascularity intensity was evaluated by means of both power Doppler imaging (PDI) and superb microvascular imaging (SMI). This study will only include high quality clinical cohort or case control studies. Statistical analyses were conducted by STATA version 15.1 software. Results: This meta-analysis included 11 studies. A total of 4342 joints were assessed through both SMI and PDI. The pooled summary odds ratio was 2.12 (95% confidence interval = 1.80-2.51) with statistical significance (z = 8.82,P < .01). In subgroup analyses, the results revealed also that SMI exhibited more sensitive performance in different subgroups. We found no evidence for publication bias (t = 0.55,P = .598). Conclusion: Our meta-analysis indicates that SMI ultrasound is more sensitive than conventional PDI in detecting synovitis in RA patients. INPLASY Registration Number: INPLASY202060089.
引用
收藏
页数:6
相关论文
共 21 条
[1]   Tightening Up? Impact of Musculoskeletal Ultrasound Disease Activity Assessment on Early Rheumatoid Arthritis Patients Treated Using a Treat to Target Strategy [J].
Dale, James ;
Purves, David ;
McConnachie, Alex ;
McInnes, Iain ;
Porter, Duncan .
ARTHRITIS CARE & RESEARCH, 2014, 66 (01) :19-26
[2]  
Du JW, 2019, HEBEI MED J, V25, P319
[3]   Ultrasound and follow-up of rheumatoid arthritis [J].
Forien, Marine ;
Ottaviani, Sebastien .
JOINT BONE SPINE, 2017, 84 (05) :531-536
[4]   Diagnostic value of the serum Midkine in patients with rheumatoid arthritis [J].
Ghafar, Muhammad Tarek Abdel ;
Haleem, Soheir Abdel ;
Shahba, Abeer ;
Sweilam, Aalaa M. .
JOURNAL OF INVESTIGATIVE MEDICINE, 2020, 68 (01) :37-44
[5]   Superb microvascular imaging with Doppler luminance using an 18-MHz probe to visualize fetal intra-abdominal blood vessels and organ microvasculature [J].
Hata, Toshiyuki ;
Koyanagi, Aya ;
Yamanishi, Tomomi ;
Bouno, Saori ;
Takayoshi, Riko ;
Miyake, Takahito .
JOURNAL OF PERINATAL MEDICINE, 2020, 48 (02) :184-188
[6]  
Jin XL, 2019, CHIN CLIN RES, V32, P1703
[7]   The superb microvascular imaging is more sensitive than conventional power Doppler imaging in detection of active synovitis in patients with rheumatoid arthritis [J].
Lee, Guen Young ;
Kim, Sujin ;
Choi, Sang Tae ;
Song, Jung Soo .
CLINICAL RHEUMATOLOGY, 2019, 38 (09) :2613-2620
[8]  
[李丽 Li Li], 2016, [中国超声医学杂志, Chinese Journal of Ultrasonic in Medicine], V32, P1004
[9]  
[刘芳 Liu Fang], 2016, [中国医学影像技术, Chinese Journal of Medical Imaging Technology], V32, P663
[10]  
[刘欢颜 Liu Huanyan], 2019, [中国超声医学杂志, Chinese Journal of Ultrasonic in Medicine], V35, P66