Immunochromatographic Assay for Ultrasensitive Detection of Aflatoxin B1 in Maize by Highly Luminescent Quantum Dot Beads

被引:232
作者
Ren, Meiling [1 ,2 ]
Xu, Hengyi [1 ]
Huang, Xiaolin [1 ,2 ]
Kuang, Min [3 ]
Xiong, Yonghua [1 ,2 ]
Xu, Hong [3 ]
Xu, Yang [1 ]
Chen, Hongyu [3 ]
Wang, Andrew [3 ]
机构
[1] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang 330047, Peoples R China
[2] Nanchang Univ, Jiangxi OAI Joint Res Inst, Nanchang 330047, Peoples R China
[3] Ocean NanoTech LLC, San Diego, CA 92126 USA
关键词
quantum dot; beads; immunochromatographic assay; quantitative detection; aflatoxin B-1; LATERAL FLOW ASSAY; MICROSPHERE SUSPENSION ARRAY; LINKED-IMMUNOSORBENT-ASSAY; PROSTATE-SPECIFIC ANTIGEN; QUANTITATIVE DETECTION; SENSITIVE DETECTION; RAPID DETECTION; STRIP TEST; IMMUNOASSAY; NANOPARTICLES;
D O I
10.1021/am503517s
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
Highly luminescent quantum dot beads (QBs) were synthesized by encapsulating CdSe/ZnS and used for the first time as immunochromatographic assay (ICA) signal amplification probe for ultrasensitive detection of aflatoxin B-1 (AFB(1)) in maize. The challenges to using high brightness QBs as probes for ICA are smooth flow of QBs and nonspecific binding on nitrocellulose (NC) membrane, which are overcome by unique polymer encapsulation of quantum dots (QDs) and surface blocking method. Under optimal conditions, the QB-based ICA (QB-ICA) sensor exhibited dynamic linear detection of AFB(1) in maize extract from 5 to 60 pg mL(-1), with a median inhibitory concentration (IC50) of 13.87 +/- 0.16 pg mL(-1), that is significantly (39-fold) lower than those of the QD as a signal probe (IC50 = 0.54 +/- 0.06 ng mL(-1)). The limit of detection (LOD) for AFB(1) using QB-ICA sensor was 0.42 pg mL(-1) in maize extract, which is approximately 2 orders of magnitude better than those of previously reported gold nanoparticle based immunochromatographic assay (AuNP-ICA) and is even comparable with or better than the conventional enzyme-linked immunosorbent assay (ELISA) method. The performance and practicability of our QB-ICA sensor were validated with a commercial ELISA kit and further confirmed with liquid chromatography tandem mass spectrometry (LC-MS/MS). Given its efficient signal amplification performance, the proposed QB-ICA offers great potential for rapid, sensitive, and cost-effective quantitative detection of analytes in food safety monitoring.
引用
收藏
页码:14215 / 14222
页数:8
相关论文
共 36 条
[1]   Development of a quantitative lateral flow immunoassay for the detection of aflatoxins in maize [J].
Anfossi, Laura ;
D'Arco, Gilda ;
Calderara, Marianna ;
Baggiani, Claudio ;
Giovannoli, Cristina ;
Giraudi, Gianfranco .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2011, 28 (02) :226-234
[2]  
[Anonymous], 2013, SURGERY OXFORD
[3]   Preparation of Polyclonal Antibodies and Development of a Direct Competitive Enzyme-Linked Immunosorbent Assay To Detect Residues of Phenylethanolamine A in Urine Samples [J].
Bai, Yuhui ;
Liu, Zhihong ;
Bi, Yanfeng ;
Wang, Xia ;
Jin, Yinzhen ;
Sun, Lei ;
Wang, Hejia ;
Zhang, Congmin ;
Xu, Shixin .
JOURNAL OF AGRICULTURAL AND FOOD CHEMISTRY, 2012, 60 (46) :11618-11624
[4]   Immunochromatographic strip test for detection of genus Cronobacter [J].
Blazkova, Martina ;
Javurkova, Barbora ;
Fukal, Ladislav ;
Rauch, Pavel .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (06) :2828-2834
[5]   A sensitive chromatographic strip test for the rapid detection of enrofloxacin in chicken muscle [J].
Chen, Xuelan ;
Xu, Hengyi ;
Lai, Weihua ;
Chen, Yuan ;
Yang, Xiaohui ;
Xiong, Yonghua .
FOOD ADDITIVES AND CONTAMINANTS PART A-CHEMISTRY ANALYSIS CONTROL EXPOSURE & RISK ASSESSMENT, 2012, 29 (03) :383-391
[6]   Lateral flow assay for simultaneous detection of cellular- and humoral immune responses [J].
Corstjens, Paul L. A. M. ;
de Dood, Claudia J. ;
van der Ploeg-van Schip, Jolien J. ;
Wiesmeijer, Karien C. ;
Riuttamaki, Terhi ;
van Meijgaarden, Krista E. ;
Spencer, John S. ;
Tanke, Hans J. ;
Ottenhoff, Tom H. M. ;
Geluk, Annemieke .
CLINICAL BIOCHEMISTRY, 2011, 44 (14-15) :1241-1246
[7]   High Sensitive Immunoassay for Multiplex Mycotoxin Detection with Photonic Crystal Microsphere Suspension Array [J].
Deng, Guozhe ;
Xu, Kun ;
Sun, Yue ;
Chen, Yu ;
Zheng, Tiesong ;
Li, Jianlin .
ANALYTICAL CHEMISTRY, 2013, 85 (05) :2833-2840
[8]   Micro-plate chemiluminescence enzyme immunoassay for aflatoxin B1 in agricultural products [J].
Fang, Luqiu ;
Chen, Hui ;
Ying, Xitang ;
Lin, Jin-Ming .
TALANTA, 2011, 84 (01) :216-222
[9]   Development of an ultrasensitive aptasensor for the detection of aflatoxin B1 [J].
Guo, Xiaodong ;
Wen, Fang ;
Zheng, Nan ;
Luo, Qiujiang ;
Wang, Haiwei ;
Wang, Hui ;
Li, Songli ;
Wang, Jiaqi .
BIOSENSORS & BIOELECTRONICS, 2014, 56 :340-344
[10]   Sensitive competitive immunoassay of multiple mycotoxins with non-fouling antigen microarray [J].
Hu, Weihua ;
Li, Xin ;
He, Guangli ;
Zhang, Zhaowei ;
Zheng, Xinting ;
Li, Peiwu ;
Li, Chang Ming .
BIOSENSORS & BIOELECTRONICS, 2013, 50 :338-344