Estimation of effective x-ray tissue attenuation differences for volumetric breast density measurement

被引:0
|
作者
Chen, Biao [1 ]
Ruth, Chris [2 ]
Jing, Zhenxue [1 ]
Ren, Baorui [2 ]
Smith, Andrew [2 ]
Kshirsagar, Ashwini [3 ]
机构
[1] Hologic Inc, 600 Technol Dr, Newark, DE 19702 USA
[2] Hologic Inc, Bedford, MA 01730 USA
[3] Hologic Inc, Santa Clara, CA 95054 USA
来源
MEDICAL IMAGING 2014: PHYSICS OF MEDICAL IMAGING | 2014年 / 9033卷
关键词
Digital Mammography; Breast Density Measurement; Breast Imaging; Cancer Risk;
D O I
10.1117/12.2042920
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Breast density has been identified to be a risk factor of developing breast cancer and an indicator of lesion diagnostic obstruction due to masking effect. Volumetric density measurement evaluates fibro-glandular volume, breast volume, and breast volume density measures that have potential advantages over area density measurement in risk assessment. One class of volume density computing methods is based on the finding of the relative fibro-glandular tissue attenuation with regards to the reference fat tissue, and the estimation of the effective x-ray tissue attenuation differences between the fibro-glandular and fat tissue is key to volumetric breast density computing. We have modeled the effective attenuation difference as a function of actual x-ray skin entrance spectrum, breast thickness, fibro-glandular tissue thickness distribution, and detector efficiency. Compared to other approaches, our method has threefold advantages: (1) avoids the system calibration-based creation of effective attenuation differences which may introduce tedious calibrations for each imaging system and may not reflect the spectrum change and scatter induced overestimation or underestimation of breast density; (2) obtains the system specific separate and differential attenuation values of fibro-glandular and fat for each mammographic image; and (3) further reduces the impact of breast thickness accuracy to volumetric breast density. A quantitative breast volume phantom with a set of equivalent fibro-glandular thicknesses has been used to evaluate the volume breast density measurement with the proposed method. The experimental results have shown that the method has significantly improved the accuracy of estimating breast density.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Measurement of breast-tissue x-ray attenuation by spectral mammography: solid lesions
    Fredenberg, Erik
    Kilburn-Toppin, Fleur
    Willsher, Paula
    Moa, Elin
    Danielsson, Mats
    Dance, David R.
    Young, Kenneth C.
    Wallis, Matthew G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (07) : 2595 - 2612
  • [2] Measurement of breast-tissue x-ray attenuation by spectral mammography: first results on cyst fluid
    Fredenberg, Erik
    Dance, David R.
    Willsher, Paula
    Moa, Elin
    von Tiedemann, Miriam
    Young, Kenneth C.
    Wallis, Matthew G.
    PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (24) : 8609 - 8620
  • [3] Measurement of breast-tissue x-ray attenuation by spectral mammography: First results on cyst fluid
    Fredenberg, Erik
    Dance, David R.
    Willsher, Paula
    von Tiedemann, Miriam
    Young, Kenneth C.
    Wallis, Matthew G.
    MEDICAL IMAGING 2013: PHYSICS OF MEDICAL IMAGING, 2013, 8668
  • [4] Mammographic Density Estimation with Automated Volumetric Breast Density Measurement
    Ko, Su Yeon
    Kim, Eun-Kyung
    Kim, Min Jung
    Moon, Hee Jung
    KOREAN JOURNAL OF RADIOLOGY, 2014, 15 (03) : 313 - 321
  • [5] Effect of tissue thickness variation in volumetric breast density estimation
    Alonzo-Proulx, Olivier
    Tyson, Albert H.
    Mawdsley, Gordon E.
    Yaffe, Martin J.
    DIGITAL MAMMOGRAPHY, PROCEEDINGS, 2008, 5116 : 659 - +
  • [6] Novel single X-ray absorptiometry method to solve for volumetric breast density in mammograms with paddle tilt
    Malkov, Serghei
    Wang, Jeff
    Shepherd, John
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [7] Optimization of volumetric breast density estimation in digital mammograms
    Holland, Katharina
    Gubern-Merida, Albert
    Mann, Ritse M.
    Karssemeijer, Nico
    PHYSICS IN MEDICINE AND BIOLOGY, 2017, 62 (09) : 3779 - 3797
  • [8] Breast tissue segmentation from x-ray radiographs
    Chen, Chen
    Nielsen, Mads
    Karssemeijer, Nico
    Brandt, Sami S.
    PHYSICS IN MEDICINE AND BIOLOGY, 2014, 59 (10) : 2445 - 2456
  • [9] Automated Classification of Breast Parenchymal Density: Topologic Analysis of X-Ray Attenuation Patterns Depicted with Digital Mammography
    Boehm, Holger F.
    Schneider, Tanja
    Buhmann-Kirchhoff, Sonja M.
    Schlossbauer, Thomas
    Rjosk-Dendorfer, Dorothea
    Britsch, Stefanie
    Reiser, Maximilian
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2008, 191 (06) : W275 - W282
  • [10] X-ray attenuation of adipose breast tissue: In-vitro and in-vivo measurements using spectral imaging
    Fredenberg, Erik
    Erhard, Klaus
    Berggren, Karl
    Dance, David R.
    Young, Kenneth C.
    Cederstrom, Bjorn
    Johansson, Henrik
    Lundqvist, Mats
    Moa, Elin
    Homan, Hanno
    Willsher, Paula
    Kilburn-Toppin, Fleur
    Wallis, Matthew
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412