Octyl-functionalized hybrid silica monolithic column for reversed-phase capillary electrochromatography

被引:88
|
作者
Yan, Li-Juan
Zhang, Qing-He [1 ]
Feng, Yu-Qi
Zhang, Wei-Bing
Li, Tong
Zhang, Li-Hua
Zhang, Yu-Kui
机构
[1] Natl Res Ctr Certified Reference Mat, Natl Inst Metrol, Beijing 100013, Peoples R China
[2] Wuhan Univ, Dept Chem, Wuhan 430072, Peoples R China
[3] Chinese Acad Sci, Dalian Inst Chem Phys, Natl Chromatog Res & Anal Ctr, Dalian 116023, Peoples R China
基金
中国国家自然科学基金;
关键词
monolithic stationary phases; reversed-phase capillary electrochromatography; organic-inorganic hybrid materials; sol-gel chemistry;
D O I
10.1016/j.chroma.2006.04.053
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hybrid silica monolithic stationary phase functionalized with octyl groups was synthesized by a two-step acid/base-catalyzed hydrolysis/co-condensation of tetraethoxysilane (TEOS) and n-octyltriethoxysilane (C-8-TEOS). The influences of deter-mining factors in the sol-gel process such as the monomer ratio and water content on the monolith formation were systematically investigated. An increase in the TEOS/C-8-TEOS ratio in the polymerization mixture shifted the pore size distribution towards smaller pore diameter with larger pore volume. The optimal TEOS/C8-TEOS volume ratio was found to be 90/50, under which condition the median pore diameter of the monolith was around 1.0 mu m with pore volume of 3.25 cm(3)/g. The chromatographic characteristics of the monolithic column prepared with the optimized fabrication condition were studied. Some aromatic compounds including alkylbenzenes, polycyclic aromatic hydrocarbons (PAHs) and phenols were successfully separated on the octyl-functionalized silica monolithic column with high column efficiency up to 180,000 plates/m. (c) 2006 Elsevier B.V. All rights reserved.
引用
收藏
页码:92 / 98
页数:7
相关论文
共 50 条
  • [21] Phenylaminopropyl silica monolithic column for pressure assisted capillary electrochromatography
    Ye, Fanggui
    Xie, Zenghong
    Wu, Xiaoping
    Lin, Xucong
    Chen, Guonan
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1117 (02) : 170 - 175
  • [22] Preparation and Characterization of Butylaminopropyl Silica Monolithic Column for Capillary Electrochromatography
    Ye Fang-Gui
    Han Yan-Yan
    Wang Shun
    Huang Bao-Jun
    Zhao Shu-Lin
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2010, 38 (02) : 192 - 196
  • [23] Monolithic column with zwitterionic stationary phase for capillary electrochromatography
    Fu, HJ
    Xie, CH
    Dong, J
    Huang, XD
    Zou, HF
    ANALYTICAL CHEMISTRY, 2004, 76 (16) : 4866 - 4874
  • [24] Separation of basic solutes by reversed-phase capillary electrochromatography
    Dittmann, MM
    Masuch, K
    Rozing, GP
    JOURNAL OF CHROMATOGRAPHY A, 2000, 887 (1-2) : 209 - 221
  • [25] PRESSURIZED FLOW ELECTROCHROMATOGRAPHY WITH REVERSED-PHASE CAPILLARY COLUMNS
    EIMER, T
    UNGER, KK
    TSUDA, T
    FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1995, 352 (7-8): : 649 - 653
  • [26] The development of reversed-phase capillary electrochromatography for the separation of steroids
    Wei, GT
    Hsu, CF
    Liu, FK
    Chou, FM
    JOURNAL OF THE CHINESE CHEMICAL SOCIETY, 2005, 52 (04) : 741 - 751
  • [27] Enantioseparation on cellulose dimethylphenylcarbamate-modified zirconia monolithic columns by reversed-phase capillary electrochromatography
    Kumar, Avvaru Praveen
    Park, Jung Hag
    JOURNAL OF CHROMATOGRAPHY A, 2010, 1217 (26) : 4494 - 4500
  • [28] Reversed-phase liquid chromatography on a microchip with sample injector and monolithic silica column
    Ishida, Akihiko
    Yoshikawa, Takahiro
    Natsume, Masamichi
    Kamidate, Tamio
    JOURNAL OF CHROMATOGRAPHY A, 2006, 1132 (1-2) : 90 - 98
  • [29] Analysis of ecstasy with a monolithic reversed-phase column
    R. C. Schneider
    K. -A. Kovar
    Chromatographia, 2003, 57 : 287 - 291
  • [30] Analysis of ecstasy with a monolithic reversed-phase column
    Schneider, RC
    Kovar, KA
    CHROMATOGRAPHIA, 2003, 57 (5-6) : 287 - 291