Two-polarizer method for the pitch angle measurement of magnetic field in a toroidal plasma

被引:4
作者
Xu, J
Ida, K
Fujita, J
Toi, K
机构
[1] Natl. Institute for Fusion Science
关键词
D O I
10.1016/S0920-3796(96)00658-8
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
Asymmetry of the motional Stark spectrum is caused by large angular divergence of an injected natural beam. To avoid this difficulty caused by the spectrum asymmetry, only the sigma component is used to determine the pitch angle in the case of a high magnetic field with an optical system that contains two polarizers tilted +/-45 degrees with respect to the horizontal direction. II is predicted that the pitch angle could be measured with an accuracy better than 0.2 degrees. (C) 1997 Elsevier Science S.A.
引用
收藏
页码:297 / 300
页数:4
相关论文
共 4 条
  • [1] CONDON EU, 1963, THEORY ATOMIC SPECTR, P398
  • [2] MAGNETIC-FIELD PITCH-ANGLE MEASUREMENTS IN THE PBX-M TOKAMAK USING THE MOTIONAL STARK-EFFECT
    LEVINTON, FM
    FONCK, RJ
    GAMMEL, GM
    KAITA, R
    KUGEL, HW
    POWELL, ET
    ROBERTS, DW
    [J]. PHYSICAL REVIEW LETTERS, 1989, 63 (19) : 2060 - 2063
  • [3] BEAM EMISSION-SPECTROSCOPY AS A COMPREHENSIVE PLASMA DIAGNOSTIC-TOOL
    MANDL, W
    WOLF, RC
    VONHELLERMANN, MG
    SUMMERS, HP
    [J]. PLASMA PHYSICS AND CONTROLLED FUSION, 1993, 35 (10) : 1373 - 1394
  • [4] POLARIMETRY OF MOTIONAL STARK-EFFECT AND DETERMINATION OF CURRENT PROFILES IN DIII-D (INVITED)
    WROBLEWSKI, D
    LAO, LL
    [J]. REVIEW OF SCIENTIFIC INSTRUMENTS, 1992, 63 (10) : 5140 - 5147