The present study sought to evaluate the impact of the flattening filter-free (FFF) technique in volumetric modulated arc therapy for lung stereotactic body radiotherapy. Its clinical safety and availability were compared with the flattening filter (FF) method. The cases of 65 patients who underwent lung volumetric modulated arc therapy-stereotactic body radiotherapy (VMAT-SBRT) using FF or FFF techniques were reviewed. A total of 55 Gy/4 fractions (fr) was prescribed for peripheral lesions or 56 Gy/7 fr for central lesions. The total monitor units (MU), treatment time, dose to tumors, dose to organs at risk, tumor control (local control rate, overall survival, progression-free survival) and adverse events between cases treated with FF and cases treated with the FFF technique were compared. A total of 35 patients were treated with conventional FF techniques prior to November 2014 and 30 patients were treated with FFF techniques after this date. It was revealed that the beam-on time was significantly shortened by the FFF technique (P<0.01). Other factors were similar for FFF and FF plans in respect to conformity (P=0.95), homogeneity (P=0.20) and other dosimetric values, including total MU and planning target volume/internal target volume coverage. The median follow-up period was 18 months (range, 2-35). One-year local control rates were 97.1 and 90.0% in the FF group and FFF groups, respectively (P=0.33). Grade 3 pneumonitis was observed in 5.8% of FF patients and 3.4% of FFF patients (P=1.00). No other adverse events >= grade 3 were observed. The results of the study suggest that VMAT-SBRT using the FFF technique shortens the treatment time for lung SBRT while maintaining a high local control rate with low toxicity.
引用
收藏
页码:3928 / 3936
页数:9
相关论文
共 50 条
  • [1] Role of Volumetric-Modulated Arc Therapy with Flattening Filter Free Delivery in Lung Stereotactic Body Radiotherapy
    Liu, Hong-Wei
    Olivotto, Ivo
    Lau, Harold
    Nugent, Zoann
    Khan, Rao
    JOURNAL OF MEDICAL IMAGING AND RADIATION SCIENCES, 2016, 47 (02) : 155 - 159
  • [2] Comparison of Flattening Filter and Flattening Filter-Free Volumetric Modulated Arc Radiotherapy in Patients with Locally Advanced Nasopharyngeal Carcinoma
    Jia, Fei
    Xu, Dandan
    Yue, Haizhen
    Wu, Hao
    Li, Guowen
    MEDICAL SCIENCE MONITOR, 2018, 24 : 8500 - 8505
  • [3] Stereotactic body radiotherapy with volumetric intensity-modulated arc therapy and flattening filter-free beams: dosimetric considerations
    Brekner, Mark Christoph
    Imhoff, Detlef
    Roedel, Claus
    Filmann, Natalie
    Licher, Joerg
    Ramm, Ulla
    Koehn, Janett
    STRAHLENTHERAPIE UND ONKOLOGIE, 2024, 200 (04) : 346 - 357
  • [4] Single-fraction flattening filter-free volumetric modulated arc therapy for lung cancer: Dosimetric results and comparison with flattened beams technique
    Barbiero, Sara
    Rink, Alexandra
    Matteucci, Fabrizio
    Fedele, David
    Paiar, Fabiola
    Pasqualetti, Francesco
    Avanzo, Michele
    MEDICAL DOSIMETRY, 2016, 41 (04) : 334 - 338
  • [5] Comparison between flattening filter and flattening filter-free photon beams in head and neck cancer patients using volumetric modulated arc therapy technique
    Alfishawy, Mahmoud Mohamed
    Elshahat, Khaled Mohamed
    Kany, Amr Ismail
    RADIATION AND ENVIRONMENTAL BIOPHYSICS, 2025, : 67 - 76
  • [6] Dosimetric comparison of intensity-modulated radiation therapy and volumetric-modulated arc therapy plans for the treatment of glioma using flattening filter-free and flattening filter modes
    Xu, Dandan
    Jia, Fei
    Li, Guowen
    Li, Hongfei
    ONCOLOGY LETTERS, 2017, 13 (05) : 3451 - 3456
  • [7] Comparison of skin dose of flattening filter and flattening filter-free beam in volumetric modulated arc therapy treatment plan for head and neck cancer
    Lam Pham Hong
    Dung Phan Tien
    Thai Hoang Huu
    Lam Nguyen Tung
    Tu Nguyen Duong
    Van Anh Nguyen Thi
    Trang Pham Quang
    2023 1ST INTERNATIONAL CONFERENCE ON HEALTH SCIENCE AND TECHNOLOGY, ICHST 2023, 2023,
  • [8] A dosimetric evaluation of flattening filter-free volumetric modulated arc therapy in nasopharyngeal carcinoma
    Fu, Guishan
    Li, Minghui
    Song, Yixin
    Dai, Jianrong
    JOURNAL OF MEDICAL PHYSICS, 2014, 39 (03) : 150 - 155
  • [9] Comparison of radiotherapy techniques with flattening filter and flattening filter-free in lung radiotherapy according to the treatment volume size
    Arslan, Alaettin
    Sengul, Burak
    SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] Optimization of leaf margins for lung stereotactic body radiotherapy using a flattening filter-free beam
    Wakai, Nobuhide
    Sumida, Iori
    Otani, Yuki
    Suzuki, Osamu
    Seo, Yuji
    Isohashi, Fumiaki
    Yoshioka, Yasuo
    Hasegawa, Masatoshi
    Ogawa, Kazuhiko
    MEDICAL PHYSICS, 2015, 42 (05) : 2125 - 2131