Sensitive voltammetric sensor based on Isopropanol-Nafion-PSS-GR nanocomposite modified glassy carbon electrode for determination of Clenbuterol in pork

被引:38
|
作者
Wang, Ling [1 ,3 ]
Yang, Ran [1 ]
Chen, Jing [1 ]
Li, Jianjun [1 ]
Qu, Lingbo [1 ,2 ]
Harrington, Peter de B. [4 ]
机构
[1] Zhengzhou Univ, Coll Chem & Mol Engn, Zhengzhou 450001, Peoples R China
[2] Henan Univ Technol, Sch Chem & Chem Engn, Zhengzhou 450001, Peoples R China
[3] Zhengzhou Normal Univ, Dept Chem, Zhengzhou 450001, Peoples R China
[4] Ohio Univ, Dept Chem & Biochem, Ctr Intelligent Chem Instrumentat, Athens, OH 45701 USA
关键词
Poly(sodium 4-styrenesulfonate); Functionalized graphene; Clenbuterol; Electrochemical sensor; NONCOVALENT FUNCTIONALIZATION; ELECTROCHEMICAL BIOSENSOR; GRAPHENE OXIDE; BETA-AGONISTS; DISPERSIONS; WATER; BETA(2)-AGONISTS; NANOPARTICLES; RACTOPAMINE; RESIDUES;
D O I
10.1016/j.foodchem.2014.04.052
中图分类号
O69 [应用化学];
学科分类号
081704 ;
摘要
In the present study, poly(sodium 4-styrenesulfonate) (PSS) functionalized graphene (GR) was synthesised via a simple one-step chemical reduction of exfoliated graphite oxides in the presence of PSS. Characterisation of as-made nanocomposite using Fourier transform infrared spectroscopy (FT-IR) and ultraviolet and visible spectroscopy (UV-vis) clearly demonstrate the successful attachment of PSS to graphene sheets. A novel clenbuterol (CLB) electrochemical sensor was fabricated based on isopropanol-Nafion-PSS-GR composite film modified glassy carbon electrode. In the Britton-Robinson buffer (pH 1.2), the sensor exhibited superior electrocatalytic activity towards the oxidation of CLB. Applying linear sweep voltammetry, a good linear relationship of the oxidation peak current with respect to concentrations of CLB cross the range of 7.5 x 10(-8)-2.5 x 10(-5) mol L-1 and a detection limit of 2.2 x 10(-8) mol L-1 were achieved. The proposed method was successfully applied for the determination of CLB in pork. (C) 2014 Elsevier Ltd. All rights reserved.
引用
收藏
页码:113 / 118
页数:6
相关论文
共 50 条
  • [1] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Xu, Ying
    Wang, Fei
    Wang, Le
    Zhao, Fangyuan
    Yang, Baocheng
    Ye, Baoxian
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1473 - 1480
  • [2] Sensitive voltammetric sensor of dihydromyricetin based on Nafion/SWNT-modified glassy carbon electrode
    Ying Xu
    Fei Wang
    Le Wang
    Fangyuan Zhao
    Baocheng Yang
    Baoxian Ye
    Journal of Solid State Electrochemistry, 2012, 16 : 1473 - 1480
  • [3] APPLICATION OF GLASSY CARBON ELECTRODE MODIFIED WITH NAFION/MWCNTS FOR SENSITIVE VOLTAMMETRIC DETERMINATION OF THYMOL
    Piech, Robert
    Paczosa-Bator, Beata
    ACTA POLONIAE PHARMACEUTICA, 2015, 72 (06): : 1081 - 1088
  • [4] High Sensitive Voltammetric Determination of Paroxetine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    INTERNATIONAL JOURNAL OF ELECTROCHEMICAL SCIENCE, 2014, 9 (12): : 7528 - 7539
  • [5] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Yang, Suling
    Qu, Lingbo
    Yang, Ran
    Li, Jianjun
    Yu, Lanlan
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2010, 40 (07) : 1371 - 1378
  • [6] Modified glassy carbon electrode with Nafion/MWNTs as a sensitive voltammetric sensor for the determination of paeonol in pharmaceutical and biological samples
    Suling Yang
    Lingbo Qu
    Ran Yang
    Jianjun Li
    Lanlan Yu
    Journal of Applied Electrochemistry, 2010, 40 : 1371 - 1378
  • [7] MWNT/Nafion composite modified glassy carbon electrode as the voltammetric sensor for sensitive determination of 8-hydroxyquinoline in cosmetic
    Guo, Sujuan
    Wu, Xianli
    Zhou, Jing
    Wang, Jing
    Yang, Baocheng
    Ye, Baoxian
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2011, 655 (01) : 45 - 49
  • [8] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Fangyuan Zhao
    Fei Wang
    Weining Zhao
    Jing Zhou
    Yang Liu
    Lina Zou
    Baoxian Ye
    Microchimica Acta, 2011, 174 : 383 - 390
  • [9] Voltammetric sensor for caffeine based on a glassy carbon electrode modified with Nafion and graphene oxide
    Zhao, Fangyuan
    Wang, Fei
    Zhao, Weining
    Zhou, Jing
    Liu, Yang
    Zou, Lina
    Ye, Baoxian
    MICROCHIMICA ACTA, 2011, 174 (3-4) : 383 - 390
  • [10] Voltammetric Determination of Codeine on Glassy Carbon Electrode Modified with Nafion/MWCNTs
    Piech, Robert
    Rumin, Martyna
    Paczosa-Bator, Beata
    JOURNAL OF ANALYTICAL METHODS IN CHEMISTRY, 2015, 2015