An Investigation into the Powder Release Behavior from Capsule-Based Dry Powder Inhalers

被引:13
作者
Huynh, B. K. [1 ,2 ]
Chen, Y. [2 ,3 ]
Fletcher, D. F. [4 ]
Young, P. [2 ,3 ]
Zhu, B. [2 ,3 ]
Traini, D. [2 ,3 ]
机构
[1] Univ Sydney, Sch Aerosp Mech & Mechatron Engn, Sydney, NSW 2006, Australia
[2] Woolcock Inst Med Res, Dept Resp Technol, Glebe, NSW 2037, Australia
[3] Univ Sydney, Sydney Med Sch, Discipline Pharmacol, Sydney, NSW 2006, Australia
[4] Univ Sydney, Sch Chem & Biomol Engn, Sydney, NSW 2006, Australia
关键词
DRUG-DELIVERY; AIR-FLOW; PERFORMANCE; PRESSURE; DESIGN; INSIGHT; DEVICE;
D O I
10.1080/02786826.2015.1082532
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
A methodology for studying the deagglomeration performance and emptying behavior of micronized mannitol powder from two commercial capsule-based dry powder inhalers (DPIs), the lowand high-resistance RS01 (R), is presented. Mathematical modeling played a key role in the interpretation of the powder release behavior from these two DPI systems. Non-linear regression models, which were characterized from the aerosol obscuration versus time profiles obtained from laser diffraction particle sizing data, were used to estimate rate constants for emptying of mannitol powder. The effects of device resistance and associated pressure drops, sampling flow rate, rates of powder emptying, and the presence of capsule on the dispersion characteristics were studied. The presence of a capsule significantly improved the aerosolization performance of mannitol powder from both inhalers, which may be due to the extended powder-air-device interactions within the device. It is important to consider the stochastic nature of movement and physical state of the capsule when assessing the aerosolization mechanisms and dispersion performance from these complex delivery systems. The methodology set out in this study has the capacity to provide a greater level of detail in the study of aerosol plume characteristics from capsule-based DPIs.
引用
收藏
页码:902 / 911
页数:10
相关论文
共 21 条
[1]   Development of a High Efficiency Dry Powder Inhaler: Effects of Capsule Chamber Design and Inhaler Surface Modifications [J].
Behara, Srinivas R. B. ;
Farkas, Dale R. ;
Hindle, Michael ;
Longest, P. Worth .
PHARMACEUTICAL RESEARCH, 2014, 31 (02) :360-372
[2]   Insight into pressure drop dependent efficiencies of dry powder inhalers [J].
Behara, Srinivas Ravindra Babu ;
Larson, Ian ;
Kippax, Paul ;
Stewart, Peter ;
Morton, David A. V. .
EUROPEAN JOURNAL OF PHARMACEUTICAL SCIENCES, 2012, 46 (03) :142-148
[3]   Kinetics of emitted mass-A study with three dry powder inhaler devices [J].
Behara, Srinivas Ravindra Babu ;
Kippax, Paul ;
Larson, Ian ;
Morton, David A. V. ;
Stewart, Peter .
CHEMICAL ENGINEERING SCIENCE, 2011, 66 (21) :5284-5292
[4]   Pressure and inspiratory flow characteristics of dry powder inhalers [J].
Cegla, UH .
RESPIRATORY MEDICINE, 2004, 98 :S22-S28
[5]   Influence of particle size, air flow, and inhaler device on the dispersion of mannitol powders as aerosols [J].
Chew, NYK ;
Chan, HK .
PHARMACEUTICAL RESEARCH, 1999, 16 (07) :1098-1103
[6]   Characterization of pharmaceutical powder inhalers: estimation of energy input for powder dispersion and effect of capsule device configuration [J].
Chew, NYK ;
Chan, HK ;
Bagster, DF ;
Mukhraiya, J .
JOURNAL OF AEROSOL SCIENCE, 2002, 33 (07) :999-1008
[7]   THE RELATIONSHIP BETWEEN POWDER INHALER RESISTANCE AND PEAK INSPIRATORY CONDITIONS IN HEALTHY-VOLUNTEERS - IMPLICATIONS FOR IN-VITRO TESTING [J].
CLARK, AR ;
HOLLINGWORTH, AM .
JOURNAL OF AEROSOL MEDICINE-DEPOSITION CLEARANCE AND EFFECTS IN THE LUNG, 1993, 6 (02) :99-110
[8]   Effect of design on the performance of a dry powder inhaler using computational fluid dynamics. Part 2: Air inlet size [J].
Coates, Matthew S. ;
Chan, Hak-Kim ;
Fletcher, David F. ;
Raper, Judy A. .
JOURNAL OF PHARMACEUTICAL SCIENCES, 2006, 95 (06) :1382-1392
[9]   The role of capsule on the performance of a dry powder inhaler using computational and experimental analyses [J].
Coates, MS ;
Fletcher, DF ;
Chan, HK ;
Raper, JA .
PHARMACEUTICAL RESEARCH, 2005, 22 (06) :923-932
[10]   Influence of air flow on the performance of a dry powder inhaler using computational and experimental analyses [J].
Coates, MS ;
Chan, HK ;
Fletcher, DF ;
Raper, JA .
PHARMACEUTICAL RESEARCH, 2005, 22 (09) :1445-1453