Usefulness of Magnetic Resonance Imaging to Guide Referral for Pulmonary Valve Replacement in Repaired Tetralogy of Fallot

被引:8
|
作者
Lewis, Matthew J. [1 ]
O'Connor, Daniel S. [1 ]
Rozenshtien, Anna [2 ]
Ye, Siqin [1 ]
Einstein, Andrew J. [1 ]
Ginns, Jonathon M. [1 ]
Rosenbaum, Marlon S. [1 ]
机构
[1] Columbia Univ, Med Ctr, Dept Med, Div Cardiol, New York, NY 10027 USA
[2] Columbia Univ, Med Ctr, Dept Radiol, Div Thorac Imaging, New York, NY USA
来源
AMERICAN JOURNAL OF CARDIOLOGY | 2014年 / 114卷 / 09期
关键词
CONGENITAL HEART-DISEASE; TERM-FOLLOW-UP; ADULTS; REGURGITATION; SURVIVORS; IMPACT;
D O I
10.1016/j.amjcard.2014.07.082
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The aim of this study was to determine if adult patients with repaired tetralogy of Fallot are being referred for pulmonary valve replacement (PVR) earlier on the basis of cardiac magnetic resonance imaging (CMR) parameters despite the absence of CMR-based recommendations in the American College of Cardiology and American Heart Association joint guidelines. Variables defined by the guidelines were analyzed in conjunction with CMR-based parameters across 3 groups defined by the release of the guidelines: (1) patients referred before the guidelines, (2) patients referred 0 to 3 years after the guidelines, and (3) patients >= 3 referred years after the guidelines. Seventy-nine patients were identified. No significant trend was observed in guideline-defined variables. Significant trends in indexed right ventricular end-diastolic volume (p = 0.034), indexed right ventricular end-systolic volume (p = 0.001), and the right ventricular ejection fraction (p = 0.005) were observed across groups. By multivariate regression, patients who underwent PVR >= 3 years after the release of the guidelines had a 29 ml/m(2) smaller indexed right ventricular end-diastolic volume (p = 0.01) and a 33 ml/m(2) smaller indexed right ventricular end-systolic volume (p < 0.001) compared with patients who underwent PVR before the release of the guidelines. PVR 0 to 3 years after the guidelines was not a significant predictor of either indexed right ventricular end-diastolic volume (p = 0.93) or indexed right ventricular end-systolic volume (p = 0.18). Patients referred for PVR >= years after the guidelines had significantly smaller CMR-based right ventricular volumes without significant trends in guideline-defined variables. Given the increased use of CMR to guide PVR referral, revisiting the guidelines to address appropriate use of CMR derived thresholds is indicated. (C) 2014 Elsevier Inc. All rights reserved.
引用
收藏
页码:1406 / 1411
页数:6
相关论文
共 50 条
  • [31] Lymphatic magnetic resonance imaging abnormalities in children with repaired tetralogy of Fallot
    Holm-Weber, Thomas
    Mohanakumar, Sheyanth
    Helt, Thora Wesenberg
    Borgwardt, Lotte
    Borgwardt, Lise
    Juul, Klaus
    Christensen, Vibeke B.
    Hjortdal, Vibeke E.
    CARDIOLOGY IN THE YOUNG, 2024,
  • [32] Impact of surgical pulmonary valve replacement on ventricular mechanics in children with repaired tetralogy of Fallot
    Yim, D.
    Mertens, L.
    Morgan, C. T.
    Friedberg, M. K.
    Grosse-Wortmann, L.
    Dragulescu, A.
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2017, 33 (05): : 711 - 720
  • [33] Electrophysiological study prior to planned pulmonary valve replacement in patients with repaired tetralogy of Fallot
    Bouyer, Benjamin
    Jalal, Zackaria
    Daniel Ramirez, F.
    Derval, Nicolas
    Iriart, Xavier
    Duchateau, Josselin
    Roubertie, Francois
    Tafer, Nadir
    Tixier, Romain
    Pambrun, Thomas
    Cheniti, Ghassen
    Ascione, Ciro
    Yokoyama, Masaaki
    Kowalewski, Christopher
    Buliard, Samuel
    Chauvel, Remi
    Arnaud, Marine
    Hocini, Meleze
    Haissaguerre, Michel
    Jais, Pierre
    Cochet, Hubert
    Thambo, Jean-Benoit
    Sacher, Frederic
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2023, 34 (06) : 1395 - 1404
  • [34] Pulmonary Valve Replacement Can be Delayed in Repaired Tetralogy of Fallot Patients with Preserved RVEF
    Ermis, Peter
    Franklin, Wayne
    Parekh, Dhaval
    CIRCULATION, 2012, 126 (21)
  • [35] Utility of Cardiac Magnetic Resonance Imaging in Predicting Atrial Arrhythmias in Repaired Tetralogy of Fallot
    Pinsker, Bret L.
    Serfas, John D.
    Awerbach, Jordan D.
    Dizon, Samantha
    Spector, Zebulon Z.
    Campbell, Michael J.
    Krasuski, Richard A.
    AMERICAN JOURNAL OF CARDIOLOGY, 2022, 174 : 151 - 157
  • [36] Approach to residual pulmonary valve dysfunction in adults with repaired tetralogy of Fallot
    Kim, Yuli Y.
    Ruckdeschel, Emily
    HEART, 2016, 102 (19) : 1520 - 1526
  • [37] Pulmonary valve replacement in patients with repaired tetralogy of Fallot: early results for recovery of right ventricular dilatation and QRS duration
    Arnaz, Ahmet
    Oktay, Ayla
    Akansel, Serdar
    Altun, Dilek
    Dogan, Abdullah
    Serban, Piotr
    Saygili, Arda
    Yalcinbas, Yusuf
    Sarioglu, Ayse
    Sarioglu, Tayyar
    TURKISH JOURNAL OF MEDICAL SCIENCES, 2018, 48 (06) : 1121 - 1128
  • [38] Impact of surgical pulmonary valve replacement on ventricular strain and synchrony in patients with repaired tetralogy of Fallot: a cardiovascular magnetic resonance feature tracking study
    Balasubramanian, Sowmya
    Harrild, David M.
    Kerur, Basavaraj
    Marcus, Edward
    del Nido, Pedro
    Geva, Tal
    Powell, Andrew J.
    JOURNAL OF CARDIOVASCULAR MAGNETIC RESONANCE, 2018, 20
  • [39] Timing of pulmonary valve replacement: can we use the same volumetric thresholds in repaired tetralogy of Fallot and pulmonary stenosis?
    Slater, Emily D.
    Lewis, Matthew J.
    Zemer-Wassercug, Noa
    Rosenbaum, Marlon S.
    CARDIOLOGY IN THE YOUNG, 2023, 33 (01) : 90 - 95
  • [40] Timing and Results of Pulmonary Valve Replacement for Pulmonary Regurgitation in Repaired Tetralogy of Fallot: A Challenge for Evidence-Based Medicine
    Vonder Muhll, Isabelle F.
    CANADIAN JOURNAL OF CARDIOLOGY, 2019, 35 (12) : 1620 - 1622