Percutaneous closure of perimembranous ventricular septal defects utilizing almost ideal Amplatzer Duct Occluder II: Why limitation in sizes?

被引:8
作者
Esmaeili, Anoosh [1 ]
Behnke-Hall, Kachina [1 ]
Schrewe, Roland [1 ]
Schranz, Dietmar [1 ]
机构
[1] Goethe Univ, Pediat Heart Ctr Hessen, Frankfurt, Germany
关键词
Amplatzer Duct Occluder II; pediatric; perimembranous ventricular septal defect; transcatheter closure; MEMBRANOUS VSD OCCLUDER; TRANSCATHETER CLOSURE; DEVICE CLOSURE; IMMEDIATE;
D O I
10.1111/chd.12731
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Aim The purpose of this study is to describe the special aspects of perimembranous ventricular septal defects (pmVSD) closure by utilizing Amplatzer Duct Occluder II (ADO II) devices with a rational request for bigger ADO-II sizes, based on our experience in transcatheter device closure of pmVSD. Methods and Results At our institution, placement of an ADO II device was used in 15 patients with pmVSD; the patients' age ranged between 6 months and 20 years. The indications for closure were CHF (n = 4), hemodynamically significant shunt (n = 7), tricuspid regurgitation (n = 3), and high risk for infective endocarditis (n = 2), respectively. The location of the VSD was infracristal in 13 patients, supracristal in 1, and a postsurgical Gerbode VSD in another one. Implantation of the device was successfully performed without embolization, any evidence of an AV block, or other conductance abnormalities during implantation and follow-up in the mean of 2.5 years (range 2 months-6.5 years). Conclusions Transcatheter closure of a pmVSD with ADO II is feasible in all pediatric and young adult age groups, by considering the device diameter limitations. The off-label use of ADO II implantation seems to be safe for VSDs closure up to 6 mm of size and feasible for various locations including unusual morphology such as postsurgical Gerbode defect.
引用
收藏
页码:389 / 395
页数:7
相关论文
共 15 条
  • [1] Transcatheter closure of perimembranous ventricular septal defects - Early and long-term results
    Butera, Gianfranco
    Carminati, Mario
    Chessa, Massimo
    Piazza, Luciane
    Micheletti, Angelo
    Negura, Diana Gabriella
    Abella, Raul
    Giamberti, Alessandro
    Frigiola, Alessandro
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 50 (12) : 1189 - 1195
  • [2] Transcatheter closure of congenital ventricular septal defects: results of the European Registry
    Carminati, Mario
    Butera, Gianfranco
    Chessa, Massimo
    De Giovanni, Joseph
    Fisher, Gunter
    Gewillig, Marc
    Peuster, Mathias
    Piechaud, Jean Francois
    Santoro, Giuseppe
    Sievert, Horst
    Spadoni, Isabella
    Walsh, Kevin
    [J]. EUROPEAN HEART JOURNAL, 2007, 28 (19) : 2361 - 2368
  • [3] Transcatheter closure of perimembranous ventricular septal defects using the new amplatzer membranous VSD occluder - Results of the US phase I trial
    Fu, YC
    Bass, J
    Amin, Z
    Radtke, W
    Cheatham, JP
    Hellenbrand, WE
    Balzer, D
    Cao, QL
    Hijazi, ZM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (02) : 319 - 325
  • [4] Ghosh S, 2018, CATHETER CARDIO INTE, V92, P921, DOI 10.1002/ccd.27177
  • [5] Catheter closure of perimembranous ventricular septal defects using the new amplatzer membranous VSD occluder: Initial clinical experience
    Hijazi, ZM
    Hakim, F
    Abu Haweleh, A
    Madani, A
    Tarawna, W
    Hiari, A
    Cao, OL
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2002, 56 (04) : 508 - 515
  • [6] Device closure of muscular ventricular septal defects using the amplatzer muscular ventricular septal defect occluder - Immediate and mid-term results of a US registry
    Holzer, R
    Balzer, D
    Cao, QL
    Lock, K
    Hijazi, ZM
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2004, 43 (07) : 1257 - 1263
  • [7] Transcatheter closure of perimembranous ventricular septal defects using the amplatzer membranous VSD occluder: Immediate and midterm results of an international registry
    Holzer, Ralf
    de Giovanni, Jo
    Walsh, Kevin P.
    Tometzki, Andrew
    Goh, T. H.
    Hakim, Fakhri
    Zabal, Carlos
    de Lezo, Jose Suarez
    Cao, Qi-Ling
    Hijazi, Ziyad M.
    [J]. CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2006, 68 (04) : 620 - 628
  • [8] Follow-Up of Patients with Interventional Closure of Ventricular Septal Defects with Amplatzer Duct Occluder II
    Kanaan, M.
    Ewert, P.
    Berger, F.
    Assa, S.
    Schubert, S.
    [J]. PEDIATRIC CARDIOLOGY, 2015, 36 (02) : 379 - 385
  • [9] Transcatheter device closure of congenital and postoperative residual ventricular septal defects
    Knauth, AL
    Lock, JE
    Perry, SB
    McElhinney, DB
    Gauvreau, K
    Landzberg, MJ
    Rome, JJ
    Hellenbrand, WE
    Ruiz, CE
    Jenkins, KJ
    [J]. CIRCULATION, 2004, 110 (05) : 501 - 507
  • [10] TRANSCATHETER CLOSURE OF VENTRICULAR SEPTAL-DEFECTS
    LOCK, JE
    BLOCK, PC
    MCKAY, RG
    BAIM, DS
    KEANE, JF
    [J]. CIRCULATION, 1988, 78 (02) : 361 - 368