Living Renal Allograft Transplantation: Diffusion-weighted MR Imaging in Longitudinal Follow-up of the Donated and the Remaining Kidney

被引:39
|
作者
Eisenberger, Ute [1 ]
Binser, Tobias [2 ]
Thoeny, Harriet C. [3 ]
Boesch, Chris [2 ]
Frey, Felix J. [1 ]
Vermathen, Peter [2 ]
机构
[1] Univ Hosp Bern, Dept Hypertens & Nephrol, CH-3010 Bern, Switzerland
[2] Univ Hosp Bern, Dept Clin Res, CH-3010 Bern, Switzerland
[3] Univ Hosp Bern, Dept Radiol Neuroradiol & Nucl Med, CH-3010 Bern, Switzerland
基金
瑞士国家科学基金会;
关键词
GLOMERULAR-FILTRATION-RATE; FOCAL GLOMERULOSCLEROSIS; MAGNETIC-RESONANCE; DONOR; NEPHRECTOMY; DYSFUNCTION; EXPERIENCE; PERFUSION; FIBROSIS; BIOPSIES;
D O I
10.1148/radiol.13122588
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To determine whether diffusion-weighted (DW) magnetic resonance (MR) imaging in living renal allograft donation allows monitoring of potential changes in the nontrans-planted remaining kidney of the donor because of unilateral nephrectomy and changes in the transplanted kidney before and after transplantation in donor and recipient, respectively, and whether DW MR parameters are correlated in the same kidney before and after transplantation. Materials and Methods: The study protocol was approved by the local ethics committee; written informed consent was obtained. Thirteen healthy kidney donors and their corresponding recipients prospectively underwent DW MR imaging (multiple b values) in donors before donation and in donors and recipients at day 8 and months 3 and 12 after donation. Total apparent diffusion coefficient (ADC(T)) values were determined; contribution of microcirculation was quantified in perfusion fraction (F-P). Longitudinal changes of diffusion parameters were compared (repeated-measures one-way analysis of variance with post hoc pairwise comparisons). Correlations were tested (linear regression). Results: ADC(T) values in nontransplanted kidney of donors increased from a preexplantation value of (188 +/- 9 [standard deviation]) to (202 +/- 11) x 10(5) mm(2)/ sec in medulla and from (199 +/- 11) to (210 +/- 13) x 10(5) mm(2)/ sec in cortex 1 week after donation (P < .004). Medullary, but not cortical, ADC(T) values stayed increased up to 1 year. ADC(T) values in allo-grafts in recipients were stable. Compared with values obtained before transplantation in donors, the corticomedullary difference was reduced in allografts (P < .03). Cortical ADC(T) values correlated with estimated glomerular filtration rate in recipients (R = 0.56, P < .001) but not donors. Cortical ADC(T) values in the same kidney before transplantation in donors correlated with those in recipients on day 8 after transplantation (R = 0.77, P =.006). F-P did not show significant changes. Conclusion: DW MR imaging depicts early adaptations in the remaining nontransplanted kidney of donors after nephrectomy. All diffusion parameters remained constant in allograft recipients after transplantation. This method has potential monitoring utility, although assessment of clinical relevance is needed. (C) RSNA, 2013
引用
收藏
页码:800 / 808
页数:9
相关论文
共 39 条
  • [21] Science to Practice: Can Diffusion-weighted MR Imaging Findings Be Used as Biomarkers to Monitor the Progression of Renal Fibrosis?
    Thoeny, Harriet C.
    Grenier, Nicolas
    RADIOLOGY, 2010, 255 (03) : 667 - 668
  • [22] Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function
    Sandner, Torleif A.
    Houck, Philip
    Runge, Val M.
    Sincleair, Spencer
    Huber, Armin M.
    Theisen, Daniel
    Reiser, Maximilian F.
    Wintersperger, Bernd J.
    EUROPEAN RADIOLOGY, 2008, 18 (10) : 2095 - 2101
  • [23] Accuracy of accelerated cine MR imaging at 3 Tesla in longitudinal follow-up of cardiac function
    Torleif A. Sandner
    Philip Houck
    Val M. Runge
    Spencer Sincleair
    Armin M. Huber
    Daniel Theisen
    Maximilian F. Reiser
    Bernd J. Wintersperger
    European Radiology, 2008, 18 : 2095 - 2101
  • [24] Quantitative assessment of renal allograft pathologic changes: comparisons of mono-exponential and bi-exponential models using diffusion-weighted imaging
    Fan, Min
    Xing, Zhaoyu
    Du, Yanan
    Pan, Liang
    Sun, Yangyang
    He, Xiaozhou
    QUANTITATIVE IMAGING IN MEDICINE AND SURGERY, 2020, 10 (06) : 1286 - +
  • [25] Long-Term Follow-Up of Renal Function in Living Kidney Donors in a Single Center
    Lu, Pei
    Tao, Jun
    Lu, Qiang
    Han, Zhijian
    Tan, Ruoyun
    Gu, Min
    Yin, Changjun
    ANNALS OF TRANSPLANTATION, 2015, 20
  • [26] Grading of clear cell renal cell carcinoma by using monoexponential, biexponential, and stretched exponential diffusion-weighted MR imaging
    Wang, Wenhui
    Wang, Lingdian
    Zhou, Jing
    Liu, Taiyuan
    Bai, Yan
    Wang, Meiyun
    FRONTIERS IN ONCOLOGY, 2024, 14
  • [27] Diffusion-weighted MR Imaging for the Assessment of Renal Function: Analysis Using Statistical Models Based on Truncated Gaussian and Gamma Distributions
    Yamada, Kentaro
    Shinmoto, Hiroshi
    Oshio, Koichi
    Ito, Seigo
    Kumagai, Hiroo
    Kaji, Tatsumi
    MAGNETIC RESONANCE IN MEDICAL SCIENCES, 2016, 15 (02) : 237 - 245
  • [28] Early and late assessment of renal allograft dysfunction using intravoxel incoherent motion (IVIM) and diffusion-weighted imaging (DWI): a prospective study
    El-Ksas, Mostafa
    EL-Metwally, Dina
    Fahmy, Dalia
    Shebel, Haytham
    ABDOMINAL RADIOLOGY, 2024, 49 (11) : 3902 - 3912
  • [29] Combined perfusion- and diffusion-weighted MR imaging in acute ischemic stroke during the 1st week: A longitudinal study
    Karonen, JO
    Liu, YW
    Vanninen, RL
    Ostergaard, L
    Partanen, PLK
    Vainio, PA
    Vanninen, EJ
    Nuutinen, J
    Roivainen, R
    Soimakallio, S
    Kuikka, IT
    Aronen, HJ
    RADIOLOGY, 2000, 217 (03) : 886 - 894
  • [30] Long-term follow-up of renal function in recipients and donors following pediatric kidney transplantation
    Berg, UB
    PEDIATRIC NEPHROLOGY, 2001, 16 (12) : 957 - 963