Implant-retained prostheses: ball vs. conus attachments - A randomized controlled clinical trial

被引:16
作者
Cepa, Sandy
Koller, Beatrice
Spies, Benedikt Christopher [1 ]
Stampf, Susanne [2 ]
Kohal, Ralf-Joachim [1 ]
机构
[1] Univ Freiburg, Ctr Dent Med, Dept Prosthet Dent Med Ctr, Hugstetter Str 55, D-79106 Freiburg, Germany
[2] Univ Basel Hosp, Clin Transplantat Immunol & Nephrol, STCS Stat & Data Management, Basel, Switzerland
关键词
ball attachment; dental implants; implant-retained mandibular overdentures; randomized controlled clinical trial; SynCone; UNSPLINTED ORAL IMPLANTS; OF-THE-LITERATURE; MANDIBULAR OVERDENTURES; SUPPORTED OVERDENTURES; PATIENT SATISFACTION; COMPLETE DENTURES; ITI IMPLANTS; 5-YEAR; SYSTEMS; COMPLICATIONS;
D O I
10.1111/clr.12779
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
ObjectiveTo evaluate implant survival, peri-implant tissue conditions, prosthodontic maintenance requirements and patient satisfaction of two differently retained implant-supported mandibular overdentures (IOD) after the 3years of observation. Materials and methodsTwenty-five patients with edentulous mandibles received two implants each. Twelve patients were randomly selected to receive ball attachments, whereas 13 patients received prefabricated coni. Implant survival, peri-implant parameters (modified Plaque Index, Bleeding on Probing, modified Gingival Index, probing depth and marginal bone loss) and patient satisfaction were assessed. Additionally, prosthodontic maintenance was monitored. Clinical and radiographic follow-ups were performed 1, 2 and 3years after prosthetic delivery. The Kaplan-Meier method was used to calculate complication rates. ResultsAfter a mean observation period of 29.6months, an implant survival rate of 100% could be observed. There were no significant differences in the peri-implant parameters. During the observation period, six patients with conus attachment refused to further participate in follow-ups due to dissatisfaction with their treatment and had to be regarded as dropouts. Based on the Kaplan-Meier method, inacceptable retention was calculated for 80% and 75% of the patients in the ball and the conus groups, respectively. Patient satisfaction was 64% for the ball- and 100% for the conus-retained IODs, the latter only respecting five of initially 13 patients. ConclusionThe evaluated treatment method revealed high implant survival rates, but the prosthetic reconstruction required intensive maintenance. Therefore, a trend toward the reduced patient satisfaction was observed, and the promoted economy of the evaluated attachment systems should be questioned. For the conical attachment, the recommendation of the manufacturer is to use four interforaminal implants to support a removable prostheses.
引用
收藏
页码:177 / 185
页数:9
相关论文
共 51 条
[41]  
Semper W, 2010, INT J ORAL MAX IMPL, V25, P86
[42]   Analytical and experimental position stability of the abutment in different dental implant systems with a conical implant-abutment connection [J].
Semper-Hogg, Wiebke ;
Kraft, Silvan ;
Stiller, Sebastian ;
Mehrhof, Juergen ;
Nelson, Katja .
CLINICAL ORAL INVESTIGATIONS, 2013, 17 (03) :1017-1023
[43]  
Shor Alexander, 2007, Compend Contin Educ Dent, V28, P80
[44]   To splint or not to splint oral implants in the implant-supported overdenture therapy? A systematic literature review [J].
Stoumpis, C. ;
Kohal, R-J. .
JOURNAL OF ORAL REHABILITATION, 2011, 38 (11) :857-869
[45]   Two implant retained overdentures-A review of the literature supporting the McGill and York consensus statements [J].
Thomason, J. M. ;
Kelly, S. A. M. ;
Bendkowski, A. ;
Ellis, J. S. .
JOURNAL OF DENTISTRY, 2012, 40 (01) :22-34
[46]  
Thomason J Mark, 2002, Eur J Prosthodont Restor Dent, V10, P95
[47]   Retention and postinsertion maintenance of bar-clip, ball and magnet attachments in mandibular implant overdenture treatment:: an in vivo comparison after 3 months of function [J].
van Kampen, F ;
Cune, M ;
van der Bilt, A ;
Bosman, F .
CLINICAL ORAL IMPLANTS RESEARCH, 2003, 14 (06) :720-726
[48]  
Wee AG, 1999, INT J PROSTHODONT, V12, P167
[49]   Clinical and radiological results of patients treated with three treatment modalities for overdentures on implants of the ITI® Dental Implant System -: A randomized controlled clinical trial [J].
Wismeijer, D ;
van Waas, MAJ ;
Mulder, J ;
Vermeeren, JIJF ;
Kalk, W .
CLINICAL ORAL IMPLANTS RESEARCH, 1999, 10 (04) :297-306
[50]  
Zhang RG, 2008, EUR J PROSTHODONT RE, V16, P61