Elderly exposure to indoor air pollutants

被引:124
作者
Almeida-Silva, M. [1 ,2 ]
Wolterbeek, H. T. [2 ]
Almeida, S. M. [1 ]
机构
[1] Univ Lisbon, Inst Super Tecn, C2TN, Loures, Portugal
[2] Delft Univ Technol, Sect RIH Radiat & Isotopes Hlth, Dept Radiat Radionuclides & Reactors, Fac Sci Appl, Delft, Netherlands
关键词
Elderly; Time-budget survey; Indoor air quality; Chemical pollutants; Exposure; TIME-ACTIVITY PATTERNS; PARTICULATE MATTER; PRIMARY-SCHOOLS; INORGANIC POLLUTANTS; HONG-KONG; QUALITY; HEALTH; POLLUTION; DISEASE; PM2.5;
D O I
10.1016/j.atmosenv.2013.11.061
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The aim of this work was to characterize the indoor air quality in Elderly Care Centers (ECCs) in order to assess the elders' daily exposure to air pollutants. Ten ECCs hosting 384 elderly were selected in Lisbon and Loures. Firstly, a time-budget survey was created based on questionnaires applied in the studied sites. Results showed that in average elders spend 95% of their time indoors splitted between bedrooms and living-rooms. Therefore, a set of physical and chemical parameters were measured continuously during the occupancy period in these two indoor micro-environments and in the outdoor. Results showed that indoor was the main environment contributing for the elders' daily exposure living in ECCs. In the indoor, the principal micro-environment contributing for the elders' daily exposure varied between bedrooms and living-rooms depending not only on the characteristics of the ECCs but also on the pollutants. The concentrations of CO2, VOCt, O-3 and PM10 exceeded the limit values predominantly due to the insufficient ventilation preconized in the studied sites. (C) 2013 Elsevier Ltd. All rights reserved.
引用
收藏
页码:54 / 63
页数:10
相关论文
共 51 条
[1]   INDOOR ORGANIC AND INORGANIC POLLUTANTS - IN-SITU FORMATION AND DRY DEPOSITION IN SOUTHEASTERN BRAZIL [J].
ALLEN, AG ;
MIGUEL, AH .
ATMOSPHERIC ENVIRONMENT, 1995, 29 (23) :3519-3526
[2]   Children exposure to atmospheric particles in indoor of Lisbon primary schools [J].
Almeida, Susana Marta ;
Canha, Nuno ;
Silva, Ana ;
Freitas, Maria do Carmo ;
Pegas, Priscilla ;
Alves, Celia ;
Evtyugina, Margarita ;
Pio, Casimiro Adriao .
ATMOSPHERIC ENVIRONMENT, 2011, 45 (40) :7594-7599
[3]  
[Anonymous], 622001 ASHRAE
[4]   The health effects of nonindustrial indoor air pollution [J].
Bernstein, Jonathan A. ;
Alexis, Neil ;
Bacchus, Hyacinth ;
Bernstein, I. Leonard ;
Fritz, Pat ;
Horner, Elliot ;
Li, Ning ;
Mason, Stephany ;
Nel, Andre ;
Oullette, John ;
Reijula, Kari ;
Reponen, Tina ;
Seltzer, James ;
Smith, Alisa ;
Tarlo, Susan M. .
JOURNAL OF ALLERGY AND CLINICAL IMMUNOLOGY, 2008, 121 (03) :585-591
[5]   Living well in care homes: a systematic review of qualitative studies [J].
Bradshaw, Siobhan Aine ;
Playford, E. Diane ;
Riazi, Afsane .
AGE AND AGEING, 2012, 41 (04) :429-440
[6]   SIMULATION OF INDOOR OZONE CONCENTRATION [J].
Bycenkiene, S. ;
Valuntaite, V. ;
Girgzdiene, R. .
LITHUANIAN JOURNAL OF PHYSICS, 2009, 49 (03) :335-339
[7]   Winter Ventilation Rates at Primary Schools: Comparison Between Portugal and Finland [J].
Canha, N. ;
Almeida, S. M. ;
Freitas, M. C. ;
Taubel, M. ;
Hanninen, O. .
JOURNAL OF TOXICOLOGY AND ENVIRONMENTAL HEALTH-PART A-CURRENT ISSUES, 2013, 76 (06) :400-408
[8]   Lichens as biomonitors at indoor environments of primary schools [J].
Canha, N. ;
Almeida-Silva, M. ;
Freitas, M. C. ;
Almeida, S. M. ;
Wolterbeek, H. Th. .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2012, 291 (01) :123-128
[9]   Indoor school environment: easy and low cost to assess inorganic pollutants [J].
Canha, N. ;
Freitas, M. C. ;
Almeida, S. M. ;
Almeida, M. ;
Ribeiro, M. ;
Galinha, C. ;
Wolterbeek, H. Th .
JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 286 (02) :495-500
[10]   Indoor air quality in primary schools [J].
Canha, Nuno ;
Martinho, Maria ;
Almeida-Silva, Marina ;
Freitas, Maria do Carmo ;
Almeida, Susana Marta ;
Pegas, Priscilla ;
Alves, Celia ;
Pio, Casimiro ;
Trancoso, Maria Ascensao ;
Sousa, Rita ;
Mouro, Filomena ;
Contreiras, Teresa .
INTERNATIONAL JOURNAL OF ENVIRONMENT AND POLLUTION, 2012, 50 (1-4) :396-410