Ultrasonographic determination of tendon compliance in human biceps brachii muscle

被引:0
作者
Ohta, M
Kanehisa, H
Fukunaga, T
机构
[1] Waseda Univ, Grad Sch Human Sci, Tokorozawa, Saitama 3591192, Japan
[2] Univ Tokyo, Dept Life Sci, Meguro Ku, Tokyo 1538902, Japan
[3] Waseda Univ, Sch Sports Sci, Tokorozawa, Saitama 3591192, Japan
关键词
human tendon; compliance; ultrasonography;
D O I
10.7600/jspfsm1949.53.337
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
This study aimed to estimate in vivo the compliance of tendon structure in human biceps brachii (BB) muscle for eight healthy male subjects. Elongation of the tendon of BB during isometric elbow-flexion was directly measured by ultrasonography. Muscle force of BB(F-BB) was calculated from the elbow flexion torque and moment arm of elbow-flexor. When the FBB increased to 80%MVC (maximum voluntary contraction), the tendinous tissue of BB was elongated 10.24 +/- 2.52 mm, horizontally. The relationship between tendon length and FBB was curvilinear and consisted of an initial region characterized by a large increase in tendon length with increasing FBB under 50% MVC, immediately followed by a linear region. The compliance of tendinous tissues, estimated from the slope of the linear region, was 0.010 +/- 0.005 mm/N, and did not show a significant correlation with MVC and muscle volume of the elbow flexors, estimated from muscle thickness. The compliance value observed here was lower than those of the medial gastrocnemius muscle and the tibialis anterior muscle, reported previously using the same ultrasonic method as the present study. This may be related to the functional differences among limb muscles in various human movements.
引用
收藏
页码:337 / 345
页数:9
相关论文
共 26 条
  • [1] BENEDICT J V, 1968, Journal of Biomechanics, V1, P53, DOI 10.1016/0021-9290(68)90038-9
  • [2] BENETT MB, 1986, J ZOOL LOND, V209, P537
  • [3] PROPERTIES OF THE TENDINOUS STRUCTURES AND SERIES ELASTIC COMPONENT OF EDL MUSCLE TENDON COMPLEX OF THE RAT
    ETTEMA, GJC
    HUIJING, PA
    [J]. JOURNAL OF BIOMECHANICS, 1989, 22 (11-12) : 1209 - 1215
  • [4] ULTRASONOGRAPHY GIVES DIRECTLY BUT NONINVASIVELY ELASTIC CHARACTERISTIC OF HUMAN TENDON IN-VIVO
    FUKASHIRO, S
    ITOH, M
    ICHINOSE, Y
    KAWAKAMI, Y
    FUKUNAGA, T
    [J]. EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY AND OCCUPATIONAL PHYSIOLOGY, 1995, 71 (06): : 555 - 557
  • [5] Tendinous movement of a human muscle during voluntary contractions determined by real-time ultrasonography
    Fukunaga, T
    Ito, M
    Ichinose, Y
    Kuno, S
    Kawakami, Y
    Fukashiro, S
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1996, 81 (03) : 1430 - 1433
  • [6] Muscle and tendon interaction during human movements
    Fukunaga, T
    Kawakami, Y
    Kubo, K
    Kanehisa, H
    [J]. EXERCISE AND SPORT SCIENCES REVIEWS, 2002, 30 (03): : 106 - 110
  • [7] CHANGES IN PENNATION WITH JOINT ANGLE AND MUSCLE TORQUE - IN-VIVO MEASUREMENTS IN HUMAN BRACHIALIS MUSCLE
    HERBERT, RD
    GANDEVIA, SC
    [J]. JOURNAL OF PHYSIOLOGY-LONDON, 1995, 484 (02): : 523 - 532
  • [8] Nonisometric behavior of fascicles during isometric contractions of a human muscle
    Ito, L
    Kawakami, Y
    Ichinose, Y
    Fukashiro, S
    Fukunaga, T
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1998, 85 (04) : 1230 - 1235
  • [9] Estimation of skeletal muscle mass by bioelectrical impedance analysis
    Janssen, I
    Heymsfield, SB
    Baumgartner, RN
    Ross, R
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 2000, 89 (02) : 465 - 471
  • [10] Architecture of contracting human muscles and its functional significance
    Kawakami, Y
    Ichinose, Y
    Kubo, K
    Ito, M
    Imai, M
    Fukunaga, T
    [J]. JOURNAL OF APPLIED BIOMECHANICS, 2000, 16 (01) : 88 - 97