Tissue response to polyglycolide, polydioxanone, polylevolactide, and metallic pins in cancellous bone:: An experimental study on rabbits

被引:22
作者
Pihlajamaki, Hard
Salminen, Sari
Laitinen, Outi
Tynninen, Olli
Bostman, Ole
机构
[1] Cent Mil Hosp, Res Inst Mil Med, FIN-00301 Helsinki, Finland
[2] Cent Mil Hosp, Dept Orthopaed Surg, FIN-00301 Helsinki, Finland
[3] Univ Helsinki Hosp, Dept Pediat Orthopaed Surg, Helsinki, Finland
[4] Altona Childrens Hosp, Dept Pediat Orthopaed Surg, Hamburg, Germany
[5] Univ Helsinki, Dept Vet Clin Sci, Helsinki, Finland
[6] Univ Helsinki, Dept Pathol, Helsinki, Finland
[7] Univ Helsinki Hosp, Dept Orthopaed & Trauma Surg, Helsinki, Finland
关键词
tissue response; bioabsorbable implants; biodegradation; biocompatibility; fracture fixation devices;
D O I
10.1002/jor.20191
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to investigate, qualitatively and histoquantitatively, the tissue response of rabbit femur cancellous bone to polyglycolide (PGA), polydioxanone (PDS), polylevolactide (PLLA), and stainless steel pins under identical conditions. Eighty knees in 50 rabbits were operated on by inserting bioabsorbable pins (PGA, PDS, or PLLA) together with metallic Kirschner wire in 60, and two metallic Kirschner wires alone in 20 knees, while 20 knees served as intact controls. Follow-up times were 3, 6, 12, 24, and 52 weeks. Cancellous bone tissue response to implants was studied using histological, histomorphometrical, microradiographical, and oxytetracycline fluorescence methods. Residual fragments of PGA and PDS were seen at 24 weeks. Complete degradation of these polymers had taken place before 52 weeks. No signs of degradation of the PLLA pins were observed within the entire follow-up period. The osteoid formation surfaces at tissue implant-interface were statistically larger in all test groups as compared to intact controls. The number of macrophages at tissue implant-interfaces increased in all bioabsorbable implant specimens until 6 weeks, and with PGA until 12 weeks. No differences in the osseous response emerged when comparing groups of bioabsorbable implants with each other or with stainless steel group. Bioabsorbable pins and metallic Kirschner wires evoked an osteoconductive response in the cancellous bone surrounding implant, but the response intensity between implants displayed no differences. This suggests a simple, nonspecific walling-off new-bone front type of response. Consequently, the polymers possessed no specific osteostimulatory or osteoinhibitory properties. Within the follow-up, no significant differences in biocompatibility between the implants appeared, and no frank inflammatory foreign-body reactions occurred. The small-volume pins obviously did not exceed the local tissue tolerance and clearing capacity of the bone. (c) 2006 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
引用
收藏
页码:1597 / 1606
页数:10
相关论文
共 48 条
[1]  
BARFOD G, 1992, ACTA ORTHOP SCAND, V63, P680
[2]   Orbital floor reconstruction with an alloplastic resorbable polydioxanone sheet [J].
Baumann, A ;
Burggasser, G ;
Gauss, N ;
Ewers, R .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (04) :367-373
[3]   LATE DEGRADATION TISSUE-RESPONSE TO POLY(L-LACTIDE) BONE PLATES AND SCREWS [J].
BERGSMA, JE ;
DEBRUIJN, WC ;
ROZEMA, FR ;
BOS, RRM ;
BOERING, G .
BIOMATERIALS, 1995, 16 (01) :25-31
[4]   DEGRADATION OF AND TISSUE REACTION TO BIODEGRADABLE POLY(L-LACTIDE) FOR USE AS INTERNAL-FIXATION OF FRACTURES - A STUDY IN RATS [J].
BOS, RRM ;
ROZEMA, FR ;
BOERING, G ;
NIJENHUIS, AJ ;
PENNINGS, AJ ;
VERWEY, AB ;
NIEUWENHUIS, P ;
JANSEN, HWB .
BIOMATERIALS, 1991, 12 (01) :32-36
[5]   DEGRADATION AND TISSUE REPLACEMENT OF AN ABSORBABLE POLYGLYCOLIDE SCREW IN THE FIXATION OF RABBIT FEMORAL OSTEOTOMIES [J].
BOSTMAN, O ;
PAIVARINTA, U ;
PARTIO, E ;
VASENIUS, J ;
MANNINEN, M ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1992, 74A (07) :1021-1031
[6]   BIODEGRADABLE INTERNAL-FIXATION FOR MALLEOLAR FRACTURES - A PROSPECTIVE RANDOMIZED TRIAL [J].
BOSTMAN, O ;
VAINIONPAA, S ;
HIRVENSALO, E ;
MAKELA, A ;
VIHTONEN, K ;
TORMALA, P ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (04) :615-619
[7]  
BOSTMAN O, 1991, ACTA ORTHOP SCAND, V62, P587
[8]   FOREIGN-BODY REACTIONS TO FRACTURE FIXATION IMPLANTS OF BIODEGRADABLE SYNTHETIC-POLYMERS [J].
BOSTMAN, O ;
HIRVENSALO, E ;
MAKINEN, J ;
ROKKANEN, P .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1990, 72 (04) :592-596
[9]  
BOSTMAN OM, 1995, CLIN ORTHOP RELAT R, P101
[10]   Late foreign-body reaction to an intraosseous bioabsorbable polylactic acid screw -: A case report [J].
Böstman, OM ;
Pihlajamaki, HK .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1998, 80A (12) :1791-1794