Correction of hemifacial microsomia with the help of mirror imaging and a rapid prototyping technique: case report
被引:13
作者:
Zhou, Libin
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R China
Zhou, Libin
[1
]
He, Lisheng
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R China
He, Lisheng
[1
]
Shang, Hongtao
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R China
Shang, Hongtao
[1
]
Liu, Guicai
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R China
Liu, Guicai
[1
]
Zhao, Jinlong
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R China
Zhao, Jinlong
[1
]
Liu, Yanpu
论文数: 0引用数: 0
h-index: 0
机构:
Fourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R ChinaFourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R China
Liu, Yanpu
[1
]
机构:
[1] Fourth Mil Med Univ, Dept Oral & Maxillofacial Surg, Sch Stomatol, Xian 710032, Peoples R China
A 23-year-old man presented with an 8-year history of unilateral hemifacial microsomia. A three-dimensional model of the maxillofacial bones was generated after acquisition of helical computed tomographic data. A customised implant model was designed by projecting a mirror image of the healthy mandible on to the three-dimensional model. A resin model of the implant was then made using a rapid prototyping machine. A polymeric biomaterial was sculpted according to the model and implanted into the affected side of the mandible to restore his facial symmetry. The hemifacial microsomia was corrected and a symmetrical facial contour obtained. No complications developed during the 6-year follow-up. (C) 2009 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.