Durability assessment of GFRP rebars in marine environments

被引:34
作者
Emparanza, Alvaro Ruiz [1 ]
Kampmann, Raphael [2 ]
De Caso, Francisco [1 ]
Morales, Carlos [1 ]
Nanni, Antonio [1 ]
机构
[1] Univ Miami, 1251 Mem Dr, Coral Gables, FL 33146 USA
[2] FAMU FSU Coll Engn, 2525 Pottsdamer St, Tallahassee, FL 32310 USA
关键词
Composite FRP rebar; Durability; Service life; Marine structures; Reinforced concrete; LONG-TERM DURABILITY; REINFORCING BARS; PREDICTION MODELS; BOND DURABILITY; CONCRETE; PERFORMANCE; SEAWATER; COMPOSITES; STRENGTH; BASALT;
D O I
10.1016/j.conbuildmat.2022.127028
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Technologies developed over the last two decades have facilitated the use of glass fiber reinforced polymer (GFRP) bars as internal reinforcement for concrete structures, specially in coastal environments, mainly due to their corrosion resistance. To-date, most durability studies have focused on a single mechanical parameter (tensile strength) and a single aging environment (exposure to high alkalinity). However, knowledge gaps exists in understanding how other mechanical parameters and relevant conditioning environments may affect the durability of GFRP bars. To this end, this study assesses the durability for different physio-mechanical properties of GFRP rebars, post exposure to accelerated conditioning in seawater.Six different GFRP rebar types were submerged in seawater tanks, at various temperatures (23 degrees C, 40 degrees C and 60 degrees C) for different time periods (60, 120, 210 and 365 days). In total six different physio-mechanical properties were assessed, including: tensile strength, E-modulus, transverse and horizontal shear strength, micro-structural composition and lastly, bond strength. It was inferred that rebars with high moisture absorption resulted in poor durability, in that it affected mainly the tensile strength. Based on the Arrhenius model, at 23 degrees C all the rebars that met the acceptance criteria by ASTM D7957 are expected to retain 85% of the tensile strength capacity.
引用
收藏
页数:13
相关论文
共 42 条
[1]  
ACI Committee 440, 2015, ACI 440.1R-15)
[2]   Effect of harsh environmental conditions on the tensile properties of GFRP bars [J].
Al-Salloum, Yousef A. ;
El-Gamal, Sherif ;
Almusallam, Tarek H. ;
Alsayed, Saleh H. ;
Aqel, Mohammed .
COMPOSITES PART B-ENGINEERING, 2013, 45 (01) :835-844
[3]  
[Anonymous], 2007, FIB B, V40/2007, P160
[4]  
[Anonymous], 2019, ASTM INT, DOI DOI 10.1520/D7705
[5]  
[Anonymous], 2017, Standard Test Methods for Liquid Limit, Plastic Limit, and Plasticity Index of Soils
[6]  
[Anonymous], 1988, GEN CHEM
[7]  
ASTM International, 2013, D1141 ASTM
[8]   A model specification for FRP composites for civil engineering structures [J].
Bank, LC ;
Gentry, TR ;
Thompson, BP ;
Russell, JS .
CONSTRUCTION AND BUILDING MATERIALS, 2003, 17 (6-7) :405-437
[9]   Durability of glass fiber-reinforced polymer reinforcing bars in concrete environment [J].
Benmokrane, B ;
Wang, P ;
Ton-That, TM ;
Rahman, H ;
Robert, JF .
JOURNAL OF COMPOSITES FOR CONSTRUCTION, 2002, 6 (03) :143-153
[10]  
Benmokrane B., 2020, J COMPOS CONSTR, V24