Determination of trace mercury in compost extract by inhibition based glucose oxidase biosensor

被引:24
作者
Liu Jian-xiao [1 ]
Xu Xiang-min [1 ,2 ]
Tang Lin [2 ]
Zeng Guang-ming [1 ,2 ]
机构
[1] Ocean Univ China, Coll Environm Sci & Engn, Qingdao 266003, Peoples R China
[2] Hunan Univ, Coll Environm Sci & Engn, Changsha 410082, Hunan, Peoples R China
基金
中国国家自然科学基金;
关键词
mercury; inhibition; glucose oxidase; biosensor; compost; PEROXIDASE-ACTIVITIES; ENZYME-INHIBITION; ELECTRODES; FERROCENE; MIXTURES;
D O I
10.1016/S1003-6326(08)60258-7
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
A novel inhibition based biosensor of glucose oxidase(GOx) for environmental mercury detection was developed. An electropolymerized aniline membrane was prepared on a platinum electrode containing ferrocene as electron transfer mediator, on which GOx was cross-linked by glutaraldehyde. The response of the sensor was based on the current reduction in the electrochemical system by inhibition of mercury against GOx electrode. The detection limit of the inhibition-based sensor for mercury is 0.49 mu g/L, and the linear response ranges are 0.49-783.21 mu g/L and 783.21 mu g/L-25.55 mg/L. The GOx membrane can be completely reactivated after inhibition, and remains 70% of the activity in more than one month. The sensor was used for mercury determination in compost extract with good results.
引用
收藏
页码:235 / 240
页数:6
相关论文
共 50 条
  • [21] Conductometric biosensor based on glucose oxidase and beta-galactosidase for specific lactose determination in milk
    Marrakchi, Mouna
    Dzyadevych, Sergei V.
    Lagarde, Florence
    Martelet, Claude
    Jaffrezic-Renault, Nicole
    MATERIALS SCIENCE & ENGINEERING C-BIOMIMETIC AND SUPRAMOLECULAR SYSTEMS, 2008, 28 (5-6): : 872 - 875
  • [22] Potentiometric glucose determination in human serum samples with glucose oxidase biosensor based on iodide electrode
    E. Karakuş
    Ş. Pekyardımcı
    E. Kiliç
    Applied Biochemistry and Microbiology, 2013, 49 : 194 - 198
  • [23] Amperometric glucose biosensor based on entrapment of glucose oxidase in a poly(3,4-ethylenedioxythiophene) film
    Nien, Po-Chin
    Tung, Tsai-Shih
    Ho, Kuo-Chuan
    ELECTROANALYSIS, 2006, 18 (13-14) : 1408 - 1415
  • [24] Amperometric glucose biosensor based on glucose oxidase-lectin biospecific interaction
    Zhang, Juanjuan
    Wang, Chengyan
    Chen, Shihong
    Yuan, Dehua
    Zhong, Xia
    ENZYME AND MICROBIAL TECHNOLOGY, 2013, 52 (03) : 134 - 140
  • [25] Determination of Glucose by an Optical Biosensor Composed of a Molecularly Imprinted Polymer, Glucose Oxidase, and Bromothymol Blue
    Hashemi-Moghaddam, Hamid
    Salamat, Qamar
    Soylak, Mustafa
    ANALYTICAL LETTERS, 2024,
  • [26] Determination of trace mercury by inhibition discoloring spectrophotometry
    Liu, JM
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2000, 28 (08) : 1021 - 1024
  • [27] Glucose monitoring by a biosensor based on mercury thin film electrodes
    Sezginturk, Mustafa Kemal
    Goktug, Tuge
    Dinckaya, Erhan
    ANALYTICAL LETTERS, 2008, 41 (06) : 1074 - 1082
  • [28] Fibre optic biosensor for the determination of D-glucose based on absorption changes of immobilized glucose oxidase
    Chudobova, I
    Vrbova, E
    Kodicek, M
    Janovcova, J
    Kas, J
    ANALYTICA CHIMICA ACTA, 1996, 319 (1-2) : 103 - 110
  • [29] A sensitive biosensor based on Os-complex mediator and glucose oxidase for low concentration glucose determination
    Jiang, Liying
    Liu, Hongmin
    Liu, Jian
    Yang, Qingde
    Cai, Xinxia
    JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2008, 619 : 11 - 16
  • [30] Glucose biosensor based on graphite electrodes modified with glucose oxidase and colloidal gold nanoparticles
    German, Natalija
    Ramanaviciene, Almira
    Voronovic, Jaroslav
    Ramanavicius, Arunas
    MICROCHIMICA ACTA, 2010, 168 (3-4) : 221 - 229