A novel automated discontinuous venous blood monitoring system for ex vivo glucose determination in humans

被引:6
作者
Schaller, R. [1 ]
Feichtner, F. [1 ]
Koehler, H. [1 ]
Bodenlenz, M. [1 ]
Plank, J. [2 ]
Wutte, A. [2 ]
Mader, J. K. [2 ]
Ellmerer, M. [2 ]
Hellmich, R.
Wedig, H.
Hainisch, R.
Pieber, T. R. [2 ]
Schaupp, L. [1 ,2 ]
机构
[1] Joanneum Res Forsch Gesell mbH, Inst Med Technol & Hlth Management, A-8010 Graz, Austria
[2] Med Univ Graz, Dept Internal Med, Div Endocrinol & Nucl Med, Graz, Austria
关键词
Glucose; Sensors; Monitoring; Blood; Automated; Ex vivo; CLINICAL-EVALUATION; ACCURACY;
D O I
10.1016/j.bios.2008.11.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
intensive insulin therapy reduces mortality and morbidity in critically ill patients but imposes great demands on medical staff who must take frequent blood samples for the determination of glucose levels. A solution to this resourcing problem would be provided by an automated blood monitoring system. The aim of the present clinical study was to evaluate such a system comprising an automatic blood sampling unit linked to a glucose biosensor. Our approach was to determine the correlation and system error of the sampling unit alone and of the combined system with respect to reference levels over 12 h in humans. Two venous cannulae were inserted to connect the automatic and reference systems to the subjects. Blood samples were taken at 15 and 30 min intervals. The median Pearson coefficient of correlation between manually and automatically withdrawn blood samples was 0.982 for the sampling unit alone and 0.950 for the complete system. The biosensor had a linear range up to 20 mmol l(-1) and a 95% response, time of <2 min. Clark Error Grid analysis showed that 96.93% of the data (228 data pairs) was in zone A and 3.07% in zone B. Insulin Titration Error Grid analysis suggested an acceptable treatment in 99.56% of cases. Implementation of a "Keep Vein Open" saline infusion into the automated blood sampling system reduced blood withdrawal failures through occluded catheters fourfold. in summary, automated blood sampling from a peripheral vein coupled with automatic glucose determination is a promising alternative to frequent manual blood sampling. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:2239 / 2245
页数:7
相关论文
共 50 条
  • [41] Implementation of a novel postoperative monitoring system using automated Modified Early Warning Scores (MEWS) incorporating end-tidal capnography
    Joseph M. Blankush
    Robbie Freeman
    Joy McIlvaine
    Trung Tran
    Stephen Nassani
    I. Michael Leitman
    Journal of Clinical Monitoring and Computing, 2017, 31 : 1081 - 1092
  • [42] A novel compact highly sensitive non-invasive microwave antenna sensor for blood glucose monitoring
    Aldhaheri, Rabah W.
    Kamili, Jagadeesh Babu
    Nella, Anveshkumar
    Sobahi, Nebras M.
    OPEN PHYSICS, 2023, 21 (01):
  • [43] Implementation of a novel postoperative monitoring system using automated Modified Early Warning Scores (MEWS) incorporating end-tidal capnography
    Blankush, Joseph M.
    Freeman, Robbie
    McIlvaine, Joy
    Trung Tran
    Nassani, Stephen
    Leitman, I. Michael
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2017, 31 (05) : 1081 - 1092
  • [44] Evaluation of a Novel Real-Time Continuous Glucose-Monitoring System for Use in Cats
    Moretti, S.
    Tschuor, F.
    Osto, M.
    Franchini, M.
    Wichert, B.
    Ackermann, M.
    Lutz, T. A.
    Reusch, C. E.
    Zini, E.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2010, 24 (01): : 120 - 126
  • [45] DETERMINATION OF D-GLUCOSE IN UNDILUTED WHOLE-BLOOD USING CHEMICALLY MODIFIED ELECTRODES AND SEGMENTED SAMPLE INJECTION IN A FLOW SYSTEM
    BUCHRASMUSSEN, T
    ANALYTICA CHIMICA ACTA, 1990, 237 (02) : 405 - 411
  • [46] Ex Vivo Glucose Detection in Human Blood Serums with Carbon Quantum Dot-Doped Oleic Acid-Treated Chitosan Nanocomposites
    Patra, Swapnita
    Sahu, Krishna Manjari
    Mahanty, Jharana
    Swain, Sarat K.
    ACS APPLIED BIO MATERIALS, 2023, 6 (12) : 5730 - 5745
  • [47] Evaluation of New Blood Glucose Monitoring System According to ISO 15197 and the Food and Drug Administration Standard
    Park, Chang-Hun
    Youn, Youngjin
    Park, Cheol-Young
    Kwon, Min-Jung
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2024, 54 (04) : 547 - 552
  • [48] Assessing the quality of Bionime self-monitoring blood glucose system Rightest GM110: A critical evaluation of interference and ambient circumstances
    Hsu, Cheng-Teng
    Hsiao, Hung-Chan
    Lee, Ming-Shih
    Chang, Shuo-Fen
    Lee, Tsung-Chien
    Tsai, Yang-Sheng
    Zen, Jyh-Myng
    CLINICA CHIMICA ACTA, 2009, 402 (1-2) : 119 - 123
  • [49] Novel Approach to Non-Invasive Blood Glucose Monitoring Based on Transmittance and Refraction of Visible Laser Light
    Ali, Haider
    Bensaali, Faycal
    Jaber, Fadi
    IEEE ACCESS, 2017, 5 : 9163 - 9174
  • [50] Ex vivo determination of glucose permeability and optical attenuation coefficient in normal and adenomatous human colon tissues using spectral domain optical coherence tomography
    Zhao, Qingliang
    Zhou, Chuanqing
    Wei, Huajiang
    He, Yonghong
    Chai, Xinyu
    Ren, Qiushi
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (10)