A novel automated discontinuous venous blood monitoring system for ex vivo glucose determination in humans

被引:6
|
作者
Schaller, R. [1 ]
Feichtner, F. [1 ]
Koehler, H. [1 ]
Bodenlenz, M. [1 ]
Plank, J. [2 ]
Wutte, A. [2 ]
Mader, J. K. [2 ]
Ellmerer, M. [2 ]
Hellmich, R.
Wedig, H.
Hainisch, R.
Pieber, T. R. [2 ]
Schaupp, L. [1 ,2 ]
机构
[1] Joanneum Res Forsch Gesell mbH, Inst Med Technol & Hlth Management, A-8010 Graz, Austria
[2] Med Univ Graz, Dept Internal Med, Div Endocrinol & Nucl Med, Graz, Austria
关键词
Glucose; Sensors; Monitoring; Blood; Automated; Ex vivo; CLINICAL-EVALUATION; ACCURACY;
D O I
10.1016/j.bios.2008.11.029
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
intensive insulin therapy reduces mortality and morbidity in critically ill patients but imposes great demands on medical staff who must take frequent blood samples for the determination of glucose levels. A solution to this resourcing problem would be provided by an automated blood monitoring system. The aim of the present clinical study was to evaluate such a system comprising an automatic blood sampling unit linked to a glucose biosensor. Our approach was to determine the correlation and system error of the sampling unit alone and of the combined system with respect to reference levels over 12 h in humans. Two venous cannulae were inserted to connect the automatic and reference systems to the subjects. Blood samples were taken at 15 and 30 min intervals. The median Pearson coefficient of correlation between manually and automatically withdrawn blood samples was 0.982 for the sampling unit alone and 0.950 for the complete system. The biosensor had a linear range up to 20 mmol l(-1) and a 95% response, time of <2 min. Clark Error Grid analysis showed that 96.93% of the data (228 data pairs) was in zone A and 3.07% in zone B. Insulin Titration Error Grid analysis suggested an acceptable treatment in 99.56% of cases. Implementation of a "Keep Vein Open" saline infusion into the automated blood sampling system reduced blood withdrawal failures through occluded catheters fourfold. in summary, automated blood sampling from a peripheral vein coupled with automatic glucose determination is a promising alternative to frequent manual blood sampling. (C) 2008 Elsevier B.V. All rights reserved.
引用
收藏
页码:2239 / 2245
页数:7
相关论文
共 50 条
  • [31] The clinical performance of the EGV1 self-monitoring blood glucose system
    Chen, Chien-Chih
    Lin, Jui-Jane
    Hung, Sheng-tien
    Chun, Peng-Ting
    Lai, Yiu-Kay
    CLINICA CHIMICA ACTA, 2012, 413 (13-14) : 1039 - 1044
  • [32] Development of Blood Glucose Monitoring System using Image Processing and Machine Learning Techniques
    Thomas, Angel
    Palekar, Sangeeta
    Kalambe, Jayu
    INTERNATIONAL JOURNAL OF ELECTRONICS AND TELECOMMUNICATIONS, 2022, 68 (02) : 323 - 328
  • [33] Practical Applications of in Vivo and ex Vivo MRI in Toxicologic Pathology Using a Novel High-performance Compact MRI System
    Tempel-Brami, Catherine
    Schiffenbauer, Yael S.
    Nyska, Abraham
    Ezov, Nati
    Spector, Itai
    Abramovitch, Rinat
    Maronpot, Robert R.
    TOXICOLOGIC PATHOLOGY, 2015, 43 (05) : 633 - 650
  • [34] Feasibility of Blood Glucose Management Using Intra-Arterial Glucose Monitoring in Combination with an Automated Insulin Titration Algorithm in Critically Ill Patients
    Mader, Julia K.
    Motschnig, Melanie
    Theiler-Schwetz, Verena
    Eibel-Reisz, Karin
    Reisinger, Alexander C.
    Lackner, Bettina
    Augustin, Thomas
    Eller, Philipp
    Mirth, Claudia
    DIABETES TECHNOLOGY & THERAPEUTICS, 2019, 21 (10) : 581 - 588
  • [35] Novel Multiplexed Biosensor System for the Determination of Lactate and Pyruvate in Blood Serum
    Kucherenko, Ivan S.
    Soldatkin, Oleksandr O.
    Topolnikova, Yaroslava V.
    Dzyadevych, Sergei V.
    Soldatkin, Alexei P.
    ELECTROANALYSIS, 2019, 31 (08) : 1625 - 1631
  • [36] Design and implementation of a novel superfusion system for ex vivo characterization of neural tissue by dielectric spectroscopy (DS)
    Dobiszewski, K. F.
    Shaker, M. R.
    Deek, M. P.
    Prodan, C.
    Hill, A. A.
    PHYSIOLOGICAL MEASUREMENT, 2011, 32 (02) : 195 - 205
  • [37] Amperometric flow system for blood glucose determination using an immobilized enzyme magnetic reactor
    Hernandez, Prisciliano
    Rodriguez, Jose A.
    Galan, Carlos A.
    Castrillejo, Yolanda
    Barrado, Enrique
    BIOSENSORS & BIOELECTRONICS, 2013, 41 : 244 - 248
  • [38] Evaluation of the appropriateness of using a continuous glucose monitoring system and a point-of-care glucometer for measuring blood glucose in horses
    Grob, Anne J.
    Delarocque, Julien
    Feige, Karsten
    Warnken, Tobias
    PFERDEHEILKUNDE, 2024, 40 (02): : 115 - 128
  • [39] A Novel Microbiosensor Microarray for Continuous ex vivo Monitoring o Gamma-Aminobutyric Acid in Real-Time
    Hossain, Imran
    Tan, Chao
    Doughty, Phillip T.
    Dutta, Gaurab
    Murray, Teresa A.
    Siddiqui, Shabnam
    Iasemidis, Leonidas
    Arumugamr, Prabhu U.
    FRONTIERS IN NEUROSCIENCE, 2018, 12
  • [40] Accuracy of a blood glucose monitoring system that recognizes insufficient sample blood volume and allows application of more blood to the same test strip
    Harrison, Bern
    Brown, Daniel
    EXPERT REVIEW OF MEDICAL DEVICES, 2020, 17 (01) : 75 - 82