Impact of fluid resuscitation with hypertonic-hydroxyethyl starch versus lactated ringer on hemorheology and microcirculation in hemorrhagic shock

被引:18
|
作者
Guerci, Philippe [1 ]
Nguyen Tran [1 ,2 ]
Menu, Patrick
Losser, Marie-Reine [3 ]
Meistelman, Claude [3 ]
Longrois, Dan [4 ]
机构
[1] Fac Med, Sch Surg, Vandoeuvre Les Nancy, France
[2] Fac Med, Grp Bioengn, Vandoeuvre Les Nancy, France
[3] Univ Hosp Nancy Brabois, Dept Anesthesiol & Intens Care Med, Vandoeuvre Les Nancy, France
[4] Univ Paris, Hop Bichat Claude Bernard, AP HP, Dept Anesthesiol & Intens Care, F-75252 Paris, France
关键词
Hemorrhagic shock; volume expander; plasma viscosity; microcirculation; pigs; functional capillary density; PULMONARY APOPTOSIS; PLASMA SUBSTITUTES; HES; 130/0.4; BLOOD; NITRITE; INCREASES; VISCOSITY; PERFUSION; NITRATE; VALUES;
D O I
10.3233/CH-141663
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The choice of volume expander for fluid resuscitation in hemorrhagic shock is still debated. Changes in plasma viscosity (PV) are barely investigated while PV modulates functional capillary density, microcirculation and organ function. The present study evaluated the impact of 2 strategies of fluid resuscitation in hemorrhagic shock in pigs. Ten pigs were subjected to hemorrhagic shock and randomly assigned to a low viscosity fluid regimen (Lactated Ringer's, LR) group or a high viscosity regimen (hypertonic-hydroxyethyl starch, HES) for volume resuscitation. Sublingual microcirculatory flow and tissue oxygen tension were assessed together with macro-and microcirculatory, biochemical and rheological variables at baseline, 30 minutes after hemorrhagic shock, immediately after reaching resuscitation endpoints (R-0), and 60 minutes after resuscitation (R-60). PV decreased similarly in both groups following resuscitation (from 1.36 [ 1.32-1.38] to 1.21 [ 1.21-1.23] for LR, and from 1.32 [ 1.31-1.32] to 1.20 [ 1.17-1.21] mPa. s for HES). No differences were found between the groups for other rheological variables, microcirculatory flow or tissue oxygen tension at R-0 and R-60. Despite a 6-fold difference in the volumes required to achieve blood flow endpoints, commercially available volume expanders had similar effects on rheological and microcirculatory variables, irrespective of their viscosity. Our findings are consistent with the absence of clinically relevant differences between crystalloid and colloid resuscitation of hemorrhagic shock.
引用
收藏
页码:301 / 317
页数:17
相关论文
共 36 条
  • [31] Hydroxyethyl starch 130/0.4 prevents the early pulmonary inflammatory response and oxidative stress after hemorrhagic shock and resuscitation in rats
    Wang, Pengfei
    Li, Yousheng
    Li, Jieshou
    INTERNATIONAL IMMUNOPHARMACOLOGY, 2009, 9 (03) : 347 - 353
  • [32] Resuscitation with centhaquin and 6% hydroxyethyl starch 130/0.4 improves survival in a swine model of hemorrhagic shock: a randomized experimental study
    Kontouli, Zinais
    Staikou, Chryssoula
    Iacovidou, Nicoletta
    Mamais, Ioannis
    Kouskouni, Evaggelia
    Papalois, Apostolos
    Papapanagiotou, Panagiotis
    Gulati, Anil
    Chalkias, Athanasios
    Xanthos, Theodoros
    EUROPEAN JOURNAL OF TRAUMA AND EMERGENCY SURGERY, 2019, 45 (06) : 1077 - 1085
  • [33] Effects of different types of fluid resuscitation for hemorrhagic shock on splanchnic organ microcirculation and renal reactive oxygen species formation
    Chun-Yu Wu
    Kuang-Cheng Chan
    Ya-Jung Cheng
    Yu-Chang Yeh
    Chiang-Ting Chien
    Critical Care, 19
  • [34] Effects of different types of fluid resuscitation for hemorrhagic shock on splanchnic organ microcirculation and renal reactive oxygen species formation
    Wu, Chun-Yu
    Chan, Kuang-Cheng
    Cheng, Ya-Jung
    Yeh, Yu-Chang
    Chien, Chiang-Ting
    CRITICAL CARE, 2015, 19
  • [35] Early difference in tissue pH and microvascular hemodynamics in hemorrhagic shock resuscitation using polyethylene glycol-albumin-and hydroxyethyl starch-based plasma expanders
    Cabrales, P
    Nacharaju, P
    Manjula, BN
    Tsai, AG
    Acharya, SA
    Intaglietta, M
    SHOCK, 2005, 24 (01): : 66 - 73
  • [36] Resuscitation from hemorrhagic shock comparing standard hemoglobin-based oxygen carrier (HBOC)-201 versus 7.5% hypertonic HBOC-201
    Rivera-Chavez, Fernando A.
    Huerta, Sergio
    Brown, Ronnie
    York, Gregory B.
    Minei, Joseph P.
    JOURNAL OF TRAUMA-INJURY INFECTION AND CRITICAL CARE, 2007, 63 (05): : 1113 - 1119