BIOMECHANICAL PERFORMANCE OF A MODIFIED DESIGN OF DYNAMIC CERVICAL IMPLANT COMPARED TO CONVENTIONAL BALL AND SOCKET DESIGN OF AN ARTIFICIAL INTERVERTEBRAL DISC IMPLANT: A FINITE ELEMENT STUDY

被引:29
作者
Bhattacharya, Shambo [1 ]
Roy, Sandipan [2 ]
Rana, Masud [3 ]
Banerjee, Sreerup [4 ]
Karmakar, Santanu Kumar [1 ]
Biswas, Jayanta Kumar [5 ]
机构
[1] Indian Inst Engn Sci & Technol, Dept Mech Engn, Sibpur, WB, India
[2] SRM Inst Sci & Technol, IDept Mech Engn, Kattankulathur 603203, Tamil Nadu, India
[3] Indian Inst Engn Sci & Technol, Dept Aerosp & Appl Mech, Sibpur, WB, India
[4] Natl Inst Technol, Dept Bio Engn, Jirania 799055, West Tripura, India
[5] JIS Coll Engn, Dept Mech Engn, Nadia 741235, W Bengal, India
关键词
TDR surgery; ROM; prodisc; modified-DCI; bone strain; MECHANICAL-PROPERTIES; SPINE; FUSION; ARTHROPLASTY; REPLACEMENT; MODEL;
D O I
10.1142/S0219519419500179
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Most of the implants used for total disc replacement (TDR) surgery are designed as a ball and socket pair aimed at providing a three-dimensional unconstrained motion. However, one of the major concerns with ball and socket design is the wear of the implant which limits its life. In this study the biomechanical performance of two types of implant designs is compared - a conventional ball and socket type (Prodisc-C) and a modified design of dynamic cervical implant (DCI) using FE analysis. A 3-dimensional geometrical model of cervical spine (C1-T1) was developed using CT scan data of a middle-aged healthy male. Subsequently, using FE analysis, the ROM values were validated with the existing literature using a compressive load in combination with different physiological motions of the neck. Furthermore, FE analysis on the two implants, fitted at C5-C6 segment, showed a significant increase in the ROM of implanted segment using Prodisc and decrease in the ROM of inferior segment, but modified-DCI restored the motion of the implanted and adjacent segments. Analysis of average bone strains adjacent to the implant showed a possibility of stress shielding for Prodisc. However, higher stress distribution on the modified-DCI limited its clinical use.
引用
收藏
页数:15
相关论文
共 31 条
[1]  
Biswas Jayanta, 2014, J Long Term Eff Med Implants, V24, P99
[2]   Effect of two-level pedicle-screw fixation with different rod materials on lumbar spine: A finite element study [J].
Biswas, Jayanta Kumar ;
Rana, Masud ;
Majumder, Santanu ;
Karmakar, Santanu Kumar ;
Roychowdhury, Amit .
JOURNAL OF ORTHOPAEDIC SCIENCE, 2018, 23 (02) :258-265
[3]   Uncinate processes and Luschka joints influence the biomechanics of the cervical spine: Quantification using a finite element model of the C5-C6 segment [J].
Clausen, JD ;
Goel, VK ;
Traynelis, VC ;
Scifert, J .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1997, 15 (03) :342-347
[4]   Biomechanical comparison between fusion of two vertebrae and implantation of an artificial intervertebral disc [J].
Denozière, G ;
Ku, DN .
JOURNAL OF BIOMECHANICS, 2006, 39 (04) :766-775
[5]   ProDisc-C An In Vivo Kinematic Study [J].
Duggal, Neil ;
Bertagnoli, Rudolf ;
Rabin, Doron ;
Wharton, Nicholas ;
Kowalczyk, Izabela .
JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2011, 24 (05) :334-339
[6]   BIOMECHANICS OF THE CRANIOCERVICAL REGION - THE ALAR AND TRANSVERSE LIGAMENTS [J].
DVORAK, J ;
SCHNEIDER, E ;
SALDINGER, P ;
RAHN, B .
JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (03) :452-461
[7]   Do design variations in the artificial disc influence cervical spine biomechanics? A finite element investigation [J].
Faizan, Ahmad ;
Goel, Vijay K. ;
Garfin, Steven R. ;
Bono, Christopher M. ;
Serhan, Hassan ;
Biyani, Ashok ;
Elgafy, Hossein ;
Krishna, Manoj ;
Friesem, Tai .
EUROPEAN SPINE JOURNAL, 2012, 21 :S653-S662
[8]   Biomechanical studies on cervical total disc arthroplasty: A literature review [J].
Galbusera, Fabio ;
Bellini, Chiara M. ;
Brayda-Bruno, Marco ;
Fornari, Maurizio .
CLINICAL BIOMECHANICS, 2008, 23 (09) :1095-1104
[9]  
Hilibrand Alan S, 2004, Spine J, V4, p190S, DOI 10.1016/j.spinee.2004.07.007
[10]   Biomechanical behavior of two different cervical total disc replacement designs in relation of concavity of articular surfaces: ProDisc-CA® vs. Prestige-LPA® [J].
Jung, Tae-Gon ;
Woo, Su-Heon ;
Park, Kwang-Min ;
Jang, Jong-Wook ;
Han, Dong-Wook ;
Lee, Sung Jae .
INTERNATIONAL JOURNAL OF PRECISION ENGINEERING AND MANUFACTURING, 2013, 14 (05) :819-824