Aortic valve anatomy and outcomes after transcatheter aortic valve implantation in bicuspid aortic valves

被引:28
作者
De Biase, C. [1 ]
Mastrokostopoulos, A. [1 ]
Philippart, R. [1 ]
Desroche, L. M. [1 ]
Blanco, S. [1 ]
Rehal, K. [1 ]
Dumonteil, N. [1 ]
Tchetche, D. [1 ]
机构
[1] Clin Pasteur, Grp Cardiovasc Interventionel GCVI, Toulouse, France
关键词
PROSTHESIS-PATIENT MISMATCH; PARAVALVULAR REGURGITATION; HEART-VALVE; SAPIEN; REPLACEMENT; STENOSIS; IMPACT; RISK; VALVULOPLASTY; MULTICENTER;
D O I
10.1016/j.ijcard.2018.01.018
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose: Aortic stenosis (AS) in bicuspid aortic valve (BAV) remains a challenge for transcatheter aortic valve implantation (TAVI). BAV is a condition encountered in young adults as well as elderly patients. Frequently we face in clinical practice elderly patients with BAV and severe AS, but there is little evidence concerning TAVI in this population. The aim of our study was to compare anatomic features and outcomes of bicuspid and tricuspid patients with AS undergoing TAVI. Methods: 83 consecutive BAV patients undergoing TAVI were matched, in a 1:2 ratio, to 166 tricuspid patients. Multi-detector computed tomography (MDCT) and transthoracic echocardiogram (TTE) were assessed at baseline. Primary endpointwas all-cause mortality and early safety at 30 days according to Valve Academic Research Consortium criteria 2 (VARC-2). Secondary endpoint included device success. Results: BAV patients presented more aortic root calcifications, smaller diameter of left ventricular outflow tract (LVOT) and dilated aorta. We did not observe any statistically significant difference concerning all-cause mortality and early safety at 30 days. However higher intra-procedural TAV-in-TAV bailout procedure was observed in the BAV cohort, with consequent reduction of device success rate. Conclusions: Patients with BAV present more complex anatomy at baseline as compared to tricuspid AS patients. These anatomical features lead to more frequent TAV-in-TAV bailout procedure and lower device success rate, but are not associated with higher mortality rate at 30 days. Our findings support the feasibility of TAVI in BAV, but larger studies with longer follow-up and a focus on sizing are required. (c) 2018 Elsevier B.V. All rights reserved.
引用
收藏
页码:56 / 60
页数:5
相关论文
共 41 条
[1]   Aortic regurgitation after transcatheter aortic valve implantation: incidence and early outcome. Results from the German transcatheter aortic valve interventions registry [J].
Abdel-Wahab, Mohamed ;
Zahn, Ralf ;
Horack, Martin ;
Gerckens, Ulrich ;
Schuler, Gerhard ;
Sievert, Horst ;
Eggebrecht, Holger ;
Senges, Jochen ;
Richardt, Gert .
HEART, 2011, 97 (11) :899-906
[2]   Can Balloon Aortic Valvuloplasty Help Determine Appropriate Transcatheter Aortic Valve Size? [J].
Babaliaros, Vasilis C. ;
Liff, David ;
Chen, Edward P. ;
Rogers, Jason H. ;
Brown, Ryan A. ;
Thourani, Vinod H. ;
Guyton, Robert A. ;
Lerakis, Stamatios ;
Stillman, Arthur E. ;
Raggi, Paolo ;
Cheesborough, Jennifer E. ;
Veladar, Emir ;
Green, Jacob T. ;
Block, Peter C. .
JACC-CARDIOVASCULAR INTERVENTIONS, 2008, 1 (05) :580-586
[3]   Baseline characteristics and outcomes after transcatheter aortic-valve implantation in patients with or without previous balloon aortic valvuloplasty: Insights from the FRANCE 2 registry [J].
Biere, Loic ;
Durfort, Amelie ;
Fouquet, Olivier ;
Hamel, Jean-Francois ;
Leprince, Pascal ;
Chevreul, Karine ;
Prat, Alain ;
Lievre, Michel ;
Donzeau-Gouge, Patrick ;
Fajadet, Jean ;
Teiger, Emmanuel ;
Eltchaninoff, Helene ;
Iung, Bernard ;
Leguerrier, Alain ;
Gilard, Martine ;
Furber, Alain .
ARCHIVES OF CARDIOVASCULAR DISEASES, 2017, 110 (10) :534-542
[4]   The Impact of Integration of a Multidetector Computed Tomography Annulus Area Sizing Algorithm on Outcomes of Transcatheter Aortic Valve Replacement A Prospective, Multicenter, Controlled Trial [J].
Binder, Ronald K. ;
Webb, John G. ;
Willson, Alexander B. ;
Urena, Marina ;
Hansson, Nicolaj C. ;
Norgaard, Bjarne L. ;
Pibarot, Philippe ;
Barbanti, Marco ;
Larose, Eric ;
Freeman, Melanie ;
Dumont, Eric ;
Thompson, Chris ;
Wheeler, Miriam ;
Moss, Robert R. ;
Yang, Tae-hyun ;
Pasian, Sergio ;
Hague, Cameron J. ;
Giang Nguyen ;
Raju, Rekha ;
Toggweiler, Stefan ;
Min, James K. ;
Wood, David A. ;
Rodes-Cabau, Josep ;
Leipsic, Jonathon .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2013, 62 (05) :431-438
[5]   Impact of Aortic Valve Calcification, as Measured by MDCT, on Survival in Patients With Aortic Stenosis [J].
Clavel, Marie-Annick ;
Pibarot, Philippe ;
Messika-Zeitoun, David ;
Capoulade, Romain ;
Malouf, Joseph ;
Aggarval, Shivani ;
Araoz, Phillip A. ;
Michelena, Hector I. ;
Cueff, Caroline ;
Larose, Eric ;
Miller, Jordan D. ;
Vahanian, Alec ;
Enriquez-Sarano, Maurice .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (12) :1202-1213
[6]   Relation between calciumburden, echocardiographic stent frame eccentricity and paravalvular leakage after corevalve transcatheter aortic valve implantation [J].
Di Martino, Luigi F. M. ;
Soliman, Osama I. I. ;
van Gils, Lennart ;
Vletter, Wim B. ;
Van Mieghem, Nicolas M. ;
Ren, Ben ;
Galema, Tjebbe W. ;
Schultz, Carl ;
de Jaegere, Peter P. T. ;
Di Biase, Matteo ;
Geleijnse, Marcel L. .
EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2017, 18 (06) :648-653
[7]   Prosthesis-patient mismatch and clinical outcomes: The evidence continues to accumulate [J].
Dumesnil, JG ;
Pibarot, P .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2006, 131 (05) :952-955
[8]   Clinical and Hemodynamic Results After Direct Transcatheter Aortic Valve Replacement Versus Pre-Implantation Balloon Aortic Valvuloplasty: A Case-Matched Analysis [J].
Ferrera, Carlos ;
Nombela-Franco, Luis ;
Garcia, Eulogio ;
Jimenez-Quevedo, Pilar ;
Biagioni, Corina ;
Gonzalo, Nieves ;
Nunez-Gil, Ivan ;
Viana-Tejedor, Ana ;
Salinas, Pablo ;
Alberto de Agustin, Jose ;
Almeria, Carlos ;
Islas, Fabian ;
Perez de Isla, Leopoldo ;
Fernandez-Perez, Cristina ;
Escaned, Javier ;
Fernandez-Ortiz, Antonio ;
Macaya, Carlos .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2017, 90 (05) :809-816
[9]   Feasibility and Outcomes of Transcatheter Aortic Valve Implantation in High-Risk Patients With Stenotic Bicuspid Aortic Valves [J].
Himbert, Dominique ;
Pontnau, Florence ;
Messika-Zeitoun, David ;
Descoutures, Fleur ;
Detaint, Delphine ;
Cueff, Caroline ;
Sordi, Martina ;
Laissy, Jean-Pierre ;
Alkhoder, Soleiman ;
Brochet, Eric ;
Iung, Bernard ;
Depoix, Jean-Pol ;
Nataf, Patrick ;
Vahanian, Alec .
AMERICAN JOURNAL OF CARDIOLOGY, 2012, 110 (06) :877-883
[10]   Predictors of Paravalvular Regurgitation After Transcatheter Aortic Valve Implantation for Aortic Stenosis Using New-Generation Balloon-Expandable SAPIEN 3 [J].
Kaneko, Hidehiro ;
Hoelschermann, Frank ;
Tambor, Grit ;
Yoon, Sung-Han ;
Neuss, Michael ;
Butter, Christian .
AMERICAN JOURNAL OF CARDIOLOGY, 2017, 119 (04) :618-622