Effect of the ratio of peak and background current durations on the fusion zone microstructure of pulsed current gas tungsten arc welded Al-Li alloy

被引:7
作者
Reddy, GM [1 ]
Gokhale, AA
机构
[1] Def Met Res Lab, Hyderabad 500058, Andhra Pradesh, India
[2] Indian Inst Technol, Madras 600036, Chennai, India
关键词
D O I
10.1023/A:1020334003055
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this study, 2 mm thick sheets of alloy 1441 were welded autogenously by pulsed current (PC) gas tungsten arc welding (GTAW). The effect of changing tp/tb ration on fusion zone structure was determined.
引用
收藏
页码:1623 / 1625