An experimental study on correlation between concrete resistivity and reinforcement corrosion rate

被引:24
作者
Ahmad, Shamsad [1 ]
机构
[1] King Fahd Univ Petr & Minerals, Dept Civil & Environm Engn, Dhahran 31261, Saudi Arabia
关键词
Monitoring; Inspection; Corrosion; Concrete; Buildings and/or civil structures; Modeling and prediction; STEEL REINFORCEMENT; POLARIZATION; HUMIDITY; MOISTURE; CHLORIDE; MORTAR;
D O I
10.1108/ACMM-07-2013-1285
中图分类号
TF [冶金工业];
学科分类号
0806 ;
摘要
Purpose - The purpose of this paper was to explore the possibility of establishing an empirical correlation between concrete resistivity and reinforcement corrosion rate utilizing the experimental data generated by measuring corrosion current density of reinforced concrete specimens subjected to chloride-induced corrosion at different levels of concrete resistivity. Design/methodology/approach - To generate concrete resistivity vs corrosion current density data in a wide range, ten reinforced concrete specimens were prepared and allowed to corrode under severe chloride exposure. After significantly corroding the specimens, they were removed from the chloride exposure and were subjected to different moisture levels for achieving variation in the resistivity of concrete so that reasonably good number of resistivity vs corrosion rate data can be obtained. Resistivity and corrosion current density tests were conducted for all the ten specimens and their values were measured in wide ranges of 0.8-65 k Omega.cm and 0.08-11 mu A/cm(2), respectively. Findings - Data generated through this study were utilized to obtain an empirical relationship between concrete resistivity and corrosion current density. The trend of results obtained using the empirical correlation model developed in the present study was in close agreement with that obtained using a theoretical model reported in literature. Originality/value - The empirical correlation between concrete resistivity and reinforcement corrosion rate obtained under this work can be used for evaluation of reinforcement corrosion utilizing the resistivity values measured non-destructively.
引用
收藏
页码:158 / 165
页数:8
相关论文
共 37 条
[1]   RELATION BETWEEN RESISTIVITY AND CORROSION RATE OF REINFORCEMENTS IN CARBONATED MORTAR MADE WITH SEVERAL CEMENT TYPES [J].
ALONSO, C ;
ANDRADE, C ;
GONZALEZ, JA .
CEMENT AND CONCRETE RESEARCH, 1988, 18 (05) :687-698
[2]  
Andrade C., 2010, P 6 INT C CONCR SEV
[3]  
Andrade C., 1986, ASTM SPEC TECH PUBL, P43
[4]   Analysis of the relation between water and resistivity isotherms in concrete [J].
Andrade, M. C. ;
Bolzoni, F. ;
Fullea, J. .
MATERIALS AND CORROSION-WERKSTOFFE UND KORROSION, 2011, 62 (02) :130-138
[5]  
Bazant Z., 1979, STRUCTURAL DIVISION, V105, P1137
[6]  
Bertolini L., 1997, 97BTR0574 TNO
[7]  
Bertolini L., 2013, Corrosion of Steel in Concrete: Prevention,Diagnosis, Repair
[8]  
Brameshuber W., 2003, P INT S NOND TEST CI
[9]   THE INFLUENCE OF INTERNAL RELATIVE-HUMIDITY ON THE RATE OF CORROSION OF STEEL EMBEDDED IN CONCRETE AND MORTAR [J].
ENEVOLDSEN, JN ;
HANSSON, CM ;
HOPE, BB .
CEMENT AND CONCRETE RESEARCH, 1994, 24 (07) :1373-1382
[10]  
Fiore S., 1996, P 4 INT S CORR REINF, P273