An Ocular Surface Prosthesis for Keratoglobus and Terrien's Marginal Degeneration

被引:15
作者
Mahadevan, Rajeswari [1 ]
Fathima, Asra [1 ]
Rajan, Rajni [1 ]
Arumugam, Amudha Oli [1 ]
机构
[1] Sankara Nethralaya, Med Res Fdn, Contact Lens Dept, Madras 600006, Tamil Nadu, India
关键词
Boston ocular surface prosthesis (BOSP); prosthetic replacement of ocular surface ecosystem (PROSE); keratoglobus; corneal ectasia; scleral contact lenses; optical coherence tomography (OCT); Terrien's marginal degeneration; OPTICAL COHERENCE TOMOGRAPHY; CORNEAL;
D O I
10.1097/OPX.0000000000000200
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose This case report describes the challenges in fitting corneas using the prosthetic replacement of ocular surface ecosystem (PROSE) device in a unique case of bilateral keratoglobus (KG) with Terrien's marginal degeneration (TMD). Case Report KG and TMD are uncommon corneal ectatic conditions, characterized by protrusion and thinning of the cornea. Optical correction with spectacles is limited, as this may not provide the best-corrected visual acuity because of irregular corneal astigmatism. Corneal gas-permeable lenses can provide optimal vision, but they have poor fitting characteristics in advanced stages. The PROSE device has the advantage of masking the irregularity of the cornea with a tear lens and a contact lens power that provides a smooth refractive surface. This case report describes the fitting aspects of the PROSE device in a case diagnosed with KG and TMD. A generous vault allows the PROSE device to sink into the conjunctiva more, causing impingement, but a PROSE with higher vault is required as corneal clearance decreases with wear time. Corneal thickness measurements during the trial can give a better idea of corneal edema expected after prescribing the PROSE device. Optical coherence tomography is a useful tool for measuring diurnal changes in the corneal thickness and vault over a period in such challenging cases. Conclusions Modification of not only the vault but also the haptic and total diameter of the device is required to achieve an optimal fit. Though challenging, successful fitting of the scleral lens in ectatic corneas is attainable, with the aid of anterior imaging and spline technologies.
引用
收藏
页码:S34 / S39
页数:6
相关论文
共 20 条
[1]   Precision of High Definition Spectral-Domain Optical Coherence Tomography for Measuring Central Corneal Thickness [J].
Correa-Perez, Maria E. ;
Lopez-Miguel, Alberto ;
Miranda-Anta, Silvia ;
Iglesias-Cortinas, Dario ;
Alio, Jorge L. ;
Maldonado, Miguel J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (04) :1752-1757
[2]   Limbal stem cells of the corneal epithelium [J].
Dua, HS ;
Azuara-Blanco, A .
SURVEY OF OPHTHALMOLOGY, 2000, 44 (05) :415-425
[3]   Standardized rigid contact lens fitting protocol for keratoconus [J].
Edrington, TB ;
Barr, JT ;
Zadnik, K ;
Davis, LJ ;
Gundel, RE ;
Libassi, DP ;
McMahon, TT ;
Gordon, MO .
OPTOMETRY AND VISION SCIENCE, 1996, 73 (06) :369-375
[4]   A novel method of fitting scleral high resolution optical coherence lenses using tomography [J].
Gemoules, Greg .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2008, 34 (02) :80-83
[5]   BLUE SCLERAE WITH KERATOGLOBUS AND BRITTLE CORNEA [J].
GREGORATOS, ND ;
BARTSOCAS, CS ;
PAPAS, K .
BRITISH JOURNAL OF OPHTHALMOLOGY, 1971, 55 (06) :424-+
[6]  
HOLDEN B A, 1989, Optometry and Vision Science, V66, P717, DOI 10.1097/00006324-198911000-00001
[7]   Pilot Study for OCT Guided Design and Fit of a Prosthetic Device for Treatment of Corneal Disease [J].
Le, Hong-Gam T. ;
Tang, Maolong ;
Ridges, Ryan ;
Huang, David ;
Jacobs, Deborah S. .
JOURNAL OF OPHTHALMOLOGY, 2012, 2012
[8]   Predicting estimates of oxygen transmissibility for scleral lenses [J].
Michaud, Langis ;
van der Worp, Eef ;
Brazeau, Daniel ;
Warde, Richard ;
Giasson, Claude J. .
CONTACT LENS & ANTERIOR EYE, 2012, 35 (06) :266-271
[9]  
POULIQUEN Y, 1985, J FR OPHTALMOL, V8, P43
[10]  
Raizada Kuldeep, 2003, Eye Contact Lens, V29, P168, DOI 10.1097/01.ICL.0000072828.14773.3F