Experimental and numerical investigation of concrete-filled stainless steel columns exposed to fire

被引:94
作者
Tao, Zhong [1 ]
Ghannam, Mohamed [1 ]
Song, Tian-Yi [1 ]
Han, Lin-Hai [2 ]
机构
[1] Univ Western Sydney, Inst Infrastruct Engn, Penrith, NSW 2751, Australia
[2] Tsinghua Univ, Dept Civil Engn, Beijing 100084, Peoples R China
基金
澳大利亚研究理事会;
关键词
Concrete-filled steel tubes; Stainless steel; Fire resistance; Post-fire; FE analysis; TUBE COLUMNS; DESIGN; STRAIN;
D O I
10.1016/j.jcsr.2015.11.003
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
This paper presents an investigation on concrete-filled stainless steel tubular (CFSST) columns in fire and after fire exposure. A total of 12 specimens were tested, including 6 CFSST columns exposed to fire and another 6 CFSST columns subjected to sequential ambient temperature loading, fire exposure with constant applied load and post-fire loading phases. A photogrammetric method was employed during the test to capture the initial imperfections of the CFSST columns and strain developments of the stainless steel tubes in fire. The main variables explored in the test program include: (a) cross-section type (circular, square); (b) axial load level (0.28-0.48); and (c) presence of reinforcement or not. A three-dimensional finite eolement (FE) model was developed by introducing the measured initial imperfections and load eccentricities. The comparison of the FE predictions and the tests performed showed a reasonable agreement. To further simplify the FE analysis, the initial geometric imperfection of a column may be simulated in the model as the first budding mode shape of the column multiplied by an amplification factor. The simplified model was verified by comparison with test results. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:120 / 134
页数:15
相关论文
共 17 条
[1]  
[Anonymous], 1993, CEB FIP MOD COD 1990
[2]  
[Anonymous], 1999, ISO 834
[3]  
[Anonymous], 2012, ABAQUS STANDARD USER
[4]   Design and behaviour of concrete-filled cold-formed stainless steel tube columns [J].
Ellobody, E ;
Young, B .
ENGINEERING STRUCTURES, 2006, 28 (05) :716-728
[5]   Stainless steel structures in fire [J].
Gardner, L. .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2007, 160 (03) :129-138
[6]  
Ghannam M., 2015, THESIS W SYDNEY U
[7]   Fire performance of concrete filled stainless steel tubular columns [J].
Han, Lin-Hai ;
Chen, Feng ;
Liao, Fei-Yu ;
Tao, Zhong ;
Uy, Brian .
ENGINEERING STRUCTURES, 2013, 56 :165-181
[8]   STRAIN OF CONCRETE DURING FIRST COOLING FROM 600-DEGREES-C UNDER LOAD [J].
KHOURY, GA ;
GRAINGER, BN ;
SULLIVAN, PJE .
MAGAZINE OF CONCRETE RESEARCH, 1986, 38 (134) :3-12
[9]   Structural design of stainless steel concrete filled columns [J].
Lam, Dennis ;
Gardner, Leroy .
JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2008, 64 (11) :1275-1282
[10]  
Photometrix Pty Ltd, 2011, AUSTR VERS 7 34 US M