Comparison of linear measurements between CBCT orthogonally synthesized cephalograms and conventional cephalograms

被引:7
作者
Yang, S. [1 ]
Liu, D. G. [2 ]
Gu, Y. [1 ]
机构
[1] Peking Univ, Dept Orthodont, Sch & Hosp Stomatol, Beijing 100871, Peoples R China
[2] Peking Univ, Dept Oral Radiol, Sch & Hosp Stomatol, Beijing 100871, Peoples R China
关键词
Cone beam computed tomography; orthodontics; measurement; BEAM COMPUTED-TOMOGRAPHY; ANGULAR MEASUREMENTS; ACCURACY; 3D; IMAGES; 2D;
D O I
10.1259/dmfr.20140024
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The purposes of the study are to investigate the consistency of linear measurements between CBCT orthogonally synthesized cephalograms and conventional cephalograms and to evaluate the influence of different magnifications on these comparisons based on a simulation algorithm. Methods: Conventional cephalograms and CBCT scans were taken on 12 dry skulls with spherical metal markers. Orthogonally synthesized cephalograms were created from CBCT data. Linear parameters on both cephalograms were measured via Photoshop CS v. 5.0 (Adobe (R) Systems, San Jose, CA), named measurement group (MG). Bland-Altman analysis was utilized to assess the agreement of two imaging modalities. Reproducibility was investigated using paired t-test. By a specific mathematical programme "cepha", corresponding linear parameters [mandibular corpus length (Go-Me), mandibular ramus length (Co-Go), posterior facial height (Go-S)] on these two types of cephalograms were calculated, named simulation group (SG). Bland-Altman analysis was used to assess the agreement between MG and SG. Simulated linear measurements with varying magnifications were generated based on "cepha" as well. Bland-Altman analysis was used to assess the agreement of simulated measurements between two modalities. Results: Bland-Altman analysis suggested the agreement between measurements on conventional cephalograms and orthogonally synthesized cephalograms, with a mean bias of 0.47 mm. Comparison between MG and SG showed that the difference did not reach clinical significance. The consistency between simulated measurements of both modalities with four different magnifications was demonstrated. Conclusions: Normative data of conventional cephalograms could be used for CBCT orthogonally synthesized cephalograms during this transitional period.
引用
收藏
页数:11
相关论文
共 28 条
  • [1] Accuracy and reliability of linear cephalometric measurements from cone-beam computed tomography scans of a dry human skull
    Berco, Mauricio
    Rigali, Paul H., Jr.
    Miner, R. Matthew
    DeLuca, Stephelynn
    Anderson, Nina K.
    Will, Leslie A.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (01) : 17.e1 - 17.e9
  • [2] BERGERSEN EO, 1980, ANGLE ORTHOD, V50, P230
  • [3] Comparison between conventional and cone-beam computed tomography-generated cephalograms
    Cattaneo, Paolo M.
    Bloch, Christian Borgkvist
    Calmar, Dorte
    Hjortshoj, Mette
    Melsen, Birte
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2008, 134 (06) : 798 - 802
  • [4] Landmark identification errors on cone-beam computed tomography-derived cephalograms and conventional digital cephalograms
    Chang, Zwei-Chieng
    Hu, Fu-Chang
    Lai, Eddie
    Yao, Chung-Chen
    Chen, Mu-Hsiung
    Chen, Yi-Jane
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2011, 140 (06) : E289 - E297
  • [5] Dibbets JMH, 2002, ANGLE ORTHOD, V72, P324
  • [6] Effect of magnification on lateral cephalometric studies
    Dibbets, JMH
    Nolte, K
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2002, 122 (02) : 196 - 201
  • [7] Development of imaging selection criteria and procedures should precede cephalometric assessment with cone-beam computed tomography
    Farman, Allan G.
    Scarfe, William C.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2006, 130 (02) : 257 - 265
  • [8] Working with DICOM craniofacial images
    Grauer, Dan
    Cevidanes, Lucia S. H.
    Proffit, William R.
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2009, 136 (03) : 460 - 470
  • [9] From 2D to 3D: an algorithm to derive normal values for 3-dimensional computerized assessment
    Gribel, Bruno Frazao
    Gribel, Marcos Nadler
    Manzi, Flavio Ricardo
    Brook, Sharon L.
    McNamara, James A., Jr.
    [J]. ANGLE ORTHODONTIST, 2011, 81 (01) : 3 - 10
  • [10] Hans MG., 2011, Seminars in Orthodontics, V17, P81