Effect of rotator cuff dysfunction on the initial mechanical stability of cementless glenoid components

被引:7
作者
Suarez, Daniel R. [1 ,2 ]
Valstar, Edward R. [1 ,3 ]
van der Linden, Jacqueline C. [2 ,4 ]
van Keulen, Fred [2 ]
Rozing, Piet M.
机构
[1] Leiden Univ MC, Biomech & Imaging Grp, Dept Orthopaed, Leiden, Netherlands
[2] Delft Univ Technol, Dept Precis & Microsyst Engn, Fac Mech Maritime & Mat Engn, Delft, Netherlands
[3] Delft Univ Technol, Dept Biomech Engn, Fac Mech Maritime & Mat Engn, Delft, Netherlands
[4] Erasmus MC, Orthopaed Res Lab, Rotterdam, Netherlands
关键词
Rotator cuff; Cementless; Modeling; Micromotions; Total shoulder arthroplasty (TSA); SHOULDER ARTHROPLASTY; MUSCULOSKELETAL MODEL; TENDON TRANSFERS; CANCELLOUS BONE; OSTEOARTHRITIS; DENSITY; FORCES; TEARS;
D O I
10.1007/s11517-009-0475-7
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
The functional outcome of shoulder replacement is related to the condition of the rotator cuff. Rotator cuff disease is a common problem in candidates for total shoulder arthroplasty; this study relates the functional status of the rotator cuff to the initial stability of a cementless glenoid implant. A 3D finite element model of a complete scapula was used to quantify the effect of a dysfunctional rotator cuff in terms of bone-implant interface micromotions when the implant is physiologically loaded shortly after surgery. Four rotator cuff conditions (from fully intact to progressively ruptured rotator cuff tendons) as well as two bone qualities were simulated in a model. Micromotions were significantly larger in the worst modeled cuff dysfunction (i.e. the supraspinatus and infraspinatus tendons were fully dysfunctional). Micromotions were also significantly different between conditions with healthy and poor bone quality. The implant's initial stability was hardly influenced by a dysfunctional supraspinatus alone. However, when the infraspinatus was also affected, the glenohumeral joint force was displaced to the component's rim resulting in larger micromotions and instability of the implant.
引用
收藏
页码:507 / 514
页数:8
相关论文
共 24 条
  • [1] Barrett W P, 1989, J Arthroplasty, V4, P91, DOI 10.1016/S0883-5403(89)80058-0
  • [2] In vivo glenohumeral contact forces -: Measurements in the first patient 7 months postoperatively
    Bergmann, G.
    Graichen, F.
    Bender, A.
    Kaab, M.
    Rohlmann, A.
    Westerhoff, P.
    [J]. JOURNAL OF BIOMECHANICS, 2007, 40 (10) : 2139 - 2149
  • [3] BOTHA CP, 2008, SIM VIS 2008 SIM VIS
  • [4] TOTAL SHOULDER ARTHROPLASTY WITH THE NEER PROSTHESIS
    COFIELD, RH
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1984, 66A (06) : 899 - 906
  • [5] DALSTRA M, 1996, 10 C EUR SOC BIOM
  • [6] Isometric shoulder muscle activation patterns for 3-D planar forces: A methodology for musculo-skeletal model validation
    de Groot, JH
    Rozendaal, LA
    Meskers, CGM
    Arwert, HJ
    [J]. CLINICAL BIOMECHANICS, 2004, 19 (08) : 790 - 800
  • [7] The influence of rotator cuff disease on the results of shoulder arthroplasty for primary osteoarthritis -: Results of a multicenter study
    Edwards, TB
    Boulahia, A
    Kempf, JF
    Boileau, P
    Némoz, C
    Walch, G
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2002, 84A (12) : 2240 - 2248
  • [8] Figgie H E 3rd, 1988, J Arthroplasty, V3, P123, DOI 10.1016/S0883-5403(88)80077-9
  • [9] Franklin J L, 1988, J Arthroplasty, V3, P39, DOI 10.1016/S0883-5403(88)80051-2
  • [10] FRINCH H, 1994, STRENGTH STRUCTURE G