Investigation of flame radiation sampling and temperature measurement through light field camera

被引:40
作者
Sun, Jun [1 ]
Hossain, Md. Moinul [2 ]
Xu, Chuanlong [1 ]
Zhang, Biao [1 ]
机构
[1] Southeast Univ, Sch Energy & Environm, 2 Sipailou Rd, Nanjing 210096, Jiangsu, Peoples R China
[2] Univ Strathclyde, Dept Elect & Elect Engn, Royal Coll Bldg,204 George St, Glasgow G1 1XW, Lanark, Scotland
基金
中国国家自然科学基金;
关键词
Focused light field camera; Traditional light field camera; Radiation sampling; 3-D reconstruction; Flame temperature; SIMULTANEOUS RECONSTRUCTION; DISTRIBUTIONS; TOMOGRAPHY; VALIDATION; FURNACE;
D O I
10.1016/j.ijheatmasstransfer.2018.01.083
中图分类号
O414.1 [热力学];
学科分类号
摘要
Different light field cameras (i.e., traditional and focused) can be used for the flame temperature measurement. But it is crucial to investigate which light field camera can provide better reconstruction accuracy for the flame temperature. In this study, numerical simulations were carried out to investigate the reconstruction accuracy of the flame temperature for the different light field cameras. The effects of flame radiation sampling of the light field cameras were described and evaluated. A novel concept of sampling region and sampling angle of the light field camera was proposed to assess the directional accuracy of the sampled rays of each pixel on the photosensor. It has been observed that the traditional light field camera sampled more rays for each pixel, hence the sampled rays of each pixel are approached less accurately from a single direction. The representative sampled ray was defined to obtain the direction of flame radiation. The radiation intensity of each pixel was calculated and indicated that the traditional light field camera sampled less radiation information than the focused light field camera. A non-negative least square (NNLS) algorithm was used to reconstruct the flame temperature. The reconstruction accuracy was also evaluated for the different distances from microlens array (MLA) to the photosensor. The results obtained from the simulations suggested that the focused light field camera performed better in comparison to the traditional light field camera. Experiments were also carried out to reconstruct the temperature distribution of ethylene diffusion flames based on the light field imaging, and to validate the proposed model. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1281 / 1296
页数:16
相关论文
共 40 条
  • [1] AN LS, 2014, POWER SYSTEM ENG, V30, P9
  • [2] [Anonymous], 2005, Comput. Sci. Tech. Rep.
  • [3] [Anonymous], 1974, Solving least squares problems
  • [4] [Anonymous], 2009, INT C COMP PHOT
  • [5] Three-dimensional temperature measurement of combustion flames using a single monochromatic CCD camera
    Brisley, PM
    Lu, G
    Yan, Y
    Cornwell, S
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2005, 54 (04) : 1417 - 1421
  • [6] Numerical and experimental validation of a three-dimensional combustion diagnostic based on tomographic chemiluminescence
    Cai, Weiwei
    Li, Xuesong
    Li, Fei
    Ma, Lin
    [J]. OPTICS EXPRESS, 2013, 21 (06): : 7050 - 7064
  • [7] Three-dimensional modeling of the instantaneous temperature distribution in a turbulent flame using a multidirectional interferometer
    Doi, Junta
    Sato, Seishiro
    [J]. OPTICAL ENGINEERING, 2007, 46 (01)
  • [8] Computer-generated hologram calculation for real scenes using a commercial portable plenoptic camera
    Endo, Yutaka
    Wakunami, Koki
    Shimobaba, Tomoyoshi
    Kakue, Takashi
    Arai, Daisuke
    Ichihashi, Yasuyuki
    Yamamoto, Kenji
    Ito, Tomoyoshi
    [J]. OPTICS COMMUNICATIONS, 2015, 356 : 468 - 471
  • [9] CALCULATION OF EMISSIVITY OF LUMINOUS FLAMES
    FELSKE, JD
    TIEN, CL
    [J]. COMBUSTION SCIENCE AND TECHNOLOGY, 1973, 7 (01) : 25 - 31
  • [10] Georgiev T., 2013, P SOC PHOTO-OPT INS, V8667