Experimental Measurements for the SiliPET project: A Small Animal PET Scanner based on Stacks of Silicon Detectors

被引:0
作者
Auricchio, N. [1 ,2 ]
Di Domenico, G. [1 ,2 ]
Milano, L. [1 ]
Malaguti, R. [2 ]
Ambrosi, G. [3 ]
Ionica, A. [3 ]
Fiandrini, E. [3 ,4 ]
Zorzi, N. [5 ]
Boscardin, M. [5 ]
Zavattini, G. [1 ,2 ]
机构
[1] Univ Ferrara, Dept Phys, I-44100 Ferrara, Italy
[2] Ist Nazl Fis Nucl, Sez Ferrara, I-44100 Ferrara, Italy
[3] Ist Nazl Fis Nucl, Sez Perugia, I-06123 Perugia, Italy
[4] Univ Perugia, Dept Phys, I-06100 Perugia, Italy
[5] ITC, Fdn Bruno, I-38050 Trento, Italy
来源
2008 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (2008 NSS/MIC), VOLS 1-9 | 2009年
关键词
HIGH-RESOLUTION DESIGN; STRIP DETECTOR;
D O I
暂无
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this paper we propose a new scanner for small-animal positron emission tomography (PET) based on stacks of double sided silicon detectors. Each stack is composed of 40 planar detectors with dimension 60 x 60 x I mm 3 and 128 orthogonal strips on both sides to read the two coordinates of interaction, the third being the detector number in the stac Multiple interactions in a stack are discarded. In this way we achieve a precise determination of the interaction point of the two 511 keV photons. The reduced dimensions of the scanner also improve the solid angle coverage resulting in a high sensitivity. Preliminary results were obtained with MEGA prototype tracker (11 double sided Si detector layers, each with a thickness of 0.5 mm and a strip pitch of 470 microns), divided into two stacks 2 cm apart made of respectively 5 and 6 prototype layers, placing a small spherical 22Na source in different positions. We report on the results, spatial resolution, spectral and timing performances obtained with double sided silicon detectors, manufactured by ITC-FBK, having an active area of 3 x 3 cm(2) and a strip pitch of 500 mm. Two different strip widths of 300 gm and 200 pin, and two thicknesses of I mm and 1.5 mm, equipped with 64 orthogonal p and n strips on opposite sides were read out with the VATAGP2.5 ASIC, a 128-channel "general purpose" charge sensitive amplifier. Each channel is composed of a low-noise/low-power preamplifier, a shaper (peaking time of 3.1 mu s) with sample/hold, multiplexed analogue readout and a fast shaper (peaking time of 1.1 mu s) that gives a trigger signal.
引用
收藏
页码:5173 / +
页数:2
相关论文
共 3 条
[1]  
AURICCHIO N, 2007, NUCL SCI S 2007 NSS, V4, P2926
[2]   SiliPET: An ultra-high resolution design of a small animal PET scanner based on stacks of double-sided silicon strip detector [J].
Di Domenico, Giovanni ;
Zavattini, Guido ;
Cesca, Nicola ;
Auricchio, Natalia ;
Andritschke, Robert ;
Schopper, Florian ;
Kanbach, Gottfried .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 571 (1-2) :22-25
[3]   SiliPET: An ultra high resolution design of a small animal PET scanner based on double sided silicon strip detector stacks [J].
Zavattini, G. ;
Cesca, N. ;
Di Domenico, G. ;
Moretti, E. ;
Sabba, N. .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 568 (01) :393-397