Helmet with specific settings versus facemask for noninvasive ventilation

被引:100
作者
Vargas, Frederic [1 ]
Thille, Arnaud [1 ]
Lyazidi, Aissam [1 ]
Master, Biomed Eng [1 ]
Campo, Ferran Roche [1 ]
Brochard, Laurent [1 ]
机构
[1] Albert Chenevier Henri Mondor Teaching Hosp, Med Intens Care Unit, Creteil, France
关键词
diaphragm function; facemask; interface; respiratory mechanics; noninvasive ventilation; extubation; helmet; ACUTE RESPIRATORY-FAILURE; OBSTRUCTIVE PULMONARY-DISEASE; POSITIVE-PRESSURE VENTILATION; CONVENTIONAL MECHANICAL VENTILATION; END-EXPIRATORY PRESSURE; AIRWAY PRESSURE; PHYSIOLOGICAL EVALUATION; ACUTE EXACERBATIONS; RANDOMIZED-TRIAL; MASK;
D O I
10.1097/CCM.0b013e31819fff93
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Objective: To compare the physiologic effects of noninvasive pressure-support ventilation (NPSV) delivered by a facemask, a helmet with the same settings, and a helmet with specific settings. Inspiratory muscle effort, gas exchange, patient-ventilator synchrony, and comfort were evaluated. Design: Prospective crossover study. Setting: A 13-bed medical intensive care unit in a university hospital. Patients: Eleven patients at risk for respiratory distress requiring early NPSV after extubation. Intervention: One hour after extubation, three 20-minute NPSV periods were delivered in a random order by facemask, helmet, and helmet with 50% increases in both pressure support and positive end-expiratory pressure and with the highest pressurization rate (95% max). Measurements and Main Results. Flow and airway, esophageal, and gastric pressure signals were measured under the three NPSV conditions and during spontaneous breathing. Compared with the facemask, the helmet with the same settings resulted in a greater inspiratory muscle effort, but this difference was abolished by the specific settings (pressure-time product in cm H(2)O . s . min(-1), 63.8 [27.3-85.9], 81.8 [36.0-111.5], and 58.0 [25.4-79.5], respectively, p < 0.05, compared with 209.3 [29.8-239.6] during spontaneous breathing). Compared with the facemask, the helmet with the same settings worsened patient-ventilator synchrony, as indicated by longer triggering-on and cycling-off delays (0.14 [0.11-0.20] seconds vs. 0.32 [0.26-0.43] seconds, p < 0.05; and 0.20 [0.08-0.24] seconds vs. 0.27 [0.25-0.35] seconds, p < 0.01, respectively). The specific settings significantly improved the triggering-on delay compared with the helmet without specific settings (p < 0.01). Tolerance was the same with the three methods. Conclusions: Our results suggest that increasing both the pressure-support level and positive end-expiratory pressure and using the highest pressurization rate may be advisable when providing NPSV via a helmet. (Crit Care Med 2009; 37:1921-1928)
引用
收藏
页码:1921 / 1928
页数:8
相关论文
共 33 条
  • [1] Noninvasive positive pressure ventilation using a helmet in patients with acute exacerbation of chronic obstructive pulmonary disease - A feasibility study
    Antonelli, M
    Pennisi, MA
    Pelosi, P
    Gregoretti, C
    Squadrone, V
    Rocco, M
    Cecchini, L
    Chiumello, D
    Severgnini, P
    Proietti, R
    Navalesi, P
    Conti, G
    [J]. ANESTHESIOLOGY, 2004, 100 (01) : 16 - 24
  • [2] New treatment of acute hypoxemic respiratory failure: Noninvasive pressure support ventilation delivered by helmet - A pilot controlled trial
    Antonelli, M
    Conti, G
    Pelosi, P
    Gregoretti, C
    Pennisi, MA
    Costa, R
    Severgnini, P
    Chiaranda, M
    Proietti, R
    [J]. CRITICAL CARE MEDICINE, 2002, 30 (03) : 602 - 608
  • [3] A comparison of noninvasive positive-pressure ventilation and conventional mechanical ventilation in patients with acute respiratory failure
    Antonelli, M
    Conti, G
    Rocco, M
    Bufi, M
    De Blasi, RA
    Vivino, G
    Gasparetto, A
    Meduri, GU
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1998, 339 (07) : 429 - 435
  • [4] Physiologic response of ventilator-dependent patients with chronic obstructive pulmonary disease to proportional assist ventilation and continuous positive airway pressure
    Appendini, L
    Purro, A
    Gudjonsdottir, M
    Baderna, P
    Patessio, A
    Zanaboni, S
    Donner, CF
    Rossi, A
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 1999, 159 (05) : 1510 - 1517
  • [5] Noninvasive ventilation reduces mortality in acute respiratory failure following lung resection
    Auriant, I
    Jallot, A
    Hervé, P
    Cerrina, J
    Ladurie, FL
    Fournier, JL
    Lescot, B
    Parquin, F
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2001, 164 (07) : 1231 - 1235
  • [6] CRITIQUE ON APPLICATION OF DIAPHRAGMATIC TIME-TENSION INDEX TO SPONTANEOUSLY BREATHING HUMANS
    BARNARD, PA
    LEVINE, S
    [J]. JOURNAL OF APPLIED PHYSIOLOGY, 1986, 60 (03) : 1067 - 1072
  • [7] BAYDUR A, 1982, AM REV RESPIR DIS, V126, P788
  • [8] Weaning from mechanical ventilation
    Boles, J-M.
    Bion, J.
    Connors, A.
    Herridge, M.
    Marsh, B.
    Melot, C.
    Pearl, R.
    Silverman, H.
    Stanchina, M.
    Vieillard-Baron, A.
    Welte, T.
    [J]. EUROPEAN RESPIRATORY JOURNAL, 2007, 29 (05) : 1033 - 1056
  • [9] NONINVASIVE VENTILATION FOR ACUTE EXACERBATIONS OF CHRONIC OBSTRUCTIVE PULMONARY-DISEASE
    BROCHARD, L
    MANCEBO, J
    WYSOCKI, M
    LOFASO, F
    CONTI, G
    RAUSS, A
    SIMONNEAU, G
    BENITO, S
    GASPARETTO, A
    LEMAIRE, F
    ISABEY, D
    HARF, A
    [J]. NEW ENGLAND JOURNAL OF MEDICINE, 1995, 333 (13) : 817 - 822
  • [10] Effects of non-invasive ventilation on middle ear function in healthy volunteers
    Cavaliere, F
    Masieri, S
    Conti, G
    Antonelli, M
    Pennisi, MA
    Filipo, R
    Proietti, R
    [J]. INTENSIVE CARE MEDICINE, 2003, 29 (04) : 611 - 614