Reliability and accuracy of heart rate variability metrics versus ECG segment duration

被引:85
作者
McNames, James
Aboy, Mateo
机构
[1] Oregon Inst Technol, Beaverton, OR 97006 USA
[2] Portland State Univ, Portland, OR 97207 USA
关键词
heart rate variability (HRV); interbeat intervals (IBI); intraclass correlation coefficient (ICC); reliability; reproducibility; repeatability; consistency;
D O I
10.1007/s11517-006-0097-2
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Despite the exponential growth in heart rate variability (HRV) research, the reproducibility and reliability of HRV metrics continues to be debated. We estimated the reliability of 11 metrics calculated from 5 min records. We also compared the accuracy of the HRV metrics calculated from ECG records spanning 10 s to 10 min as compared with the metrics calculated from 5 min records. The mean heart rate was more reproducible and could be more accurately estimated from very short segments (< 1 min) than any of the other HRV metrics. HRV metrics that effectively highpass filter the R-R interval series were more reliable than the other metrics and could be more accurately estimated from very short segments. This indicates that most of the HRV is caused by drift and nonstationary effects. Metrics that are sensitive to low frequency components of HRV have poor repeatability and cannot be estimated accurately from short segments (< 10 min).
引用
收藏
页码:747 / 756
页数:10
相关论文
共 61 条
[1]   POWER SPECTRUM ANALYSIS OF HEART-RATE FLUCTUATION - A QUANTITATIVE PROBE OF BEAT-TO-BEAT CARDIOVASCULAR CONTROL [J].
AKSELROD, S ;
GORDON, D ;
UBEL, FA ;
SHANNON, DC ;
BARGER, AC ;
COHEN, RJ .
SCIENCE, 1981, 213 (4504) :220-222
[2]   Reliability of noninvasive methods to measure cardiac autonomic function [J].
Amara, CE ;
Wolfe, LA .
CANADIAN JOURNAL OF APPLIED PHYSIOLOGY-REVUE CANADIENNE DE PHYSIOLOGIE APPLIQUEE, 1998, 23 (04) :396-408
[3]   Physical activity influences heart rate variability and very-low-frequency components in Holter electrocardiograms [J].
Bernardi, L ;
Valle, F ;
Coco, M ;
Calciati, A ;
Sleight, P .
CARDIOVASCULAR RESEARCH, 1996, 32 (02) :234-237
[4]   High-resolution QRS fiducial point corrections in sparsely sampled ECG recordings [J].
Bragge, T ;
Tarvainen, MP ;
Ranta-Aho, PO ;
Karjalainen, PA .
PHYSIOLOGICAL MEASUREMENT, 2005, 26 (05) :743-751
[5]  
BREMBILLAPERROT B, 2004, ARCH MAL COEUR VAISS, V2, P245
[6]  
BREUER HWM, 1992, Z KARDIOL, V81, P475
[7]  
Buchman Timothy G, 2002, Curr Opin Crit Care, V8, P311, DOI 10.1097/00075198-200208000-00007
[8]   Short- and long-term reproducibility of heart rate variability in patients with long-standing type I diabetes mellitus [J].
Burger, AJ ;
Charlamb, M ;
Weinrauch, LA ;
DElia, JA .
AMERICAN JOURNAL OF CARDIOLOGY, 1997, 80 (09) :1198-1202
[9]  
Camm AJ, 1996, CIRCULATION, V93, P1043
[10]  
Carrasco S., 2003, Journal of Medical Engineering & Technology, V27, P241, DOI 10.1080/0309190031000111380