Compressed sensing reconstruction of cardiac cine MRI using golden angle spiral trajectories

被引:19
作者
Tolouee, Azar [1 ]
Alirezaie, Javad [1 ]
Babyn, Paul [2 ]
机构
[1] Ryerson Univ, Dept Elect & Comp Engn, Toronto, ON M5B 2K3, Canada
[2] Univ Saskatoon Hlth Reg, Dept Med Imaging, Royal Univ Hosp, Saskatoon, SK, Canada
基金
加拿大自然科学与工程研究理事会;
关键词
Compressed sensing; Spiral trajectory; k-t space sparsity; Cardiac cine MRI; K-T FOCUSS; FRAMEWORK; MOTION;
D O I
10.1016/j.jmr.2015.09.003
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In dynamic cardiac cine Magnetic Resonance Imaging (Mm), the spatiotemporal resolution is limited by the low imaging speed. Compressed sensing (CS) theory has been applied to improve the imaging speed and thus the spatiotemporal resolution. The purpose of this paper is to improve CS reconstruction of under sampled data by exploiting spatiotemporal sparsity and efficient spiral trajectories. We extend k-t sparse algorithm to spiral trajectories to achieve high spatio temporal resolutions in cardiac cine imaging. We have exploited spatiotemporal sparsity of cardiac cine MRI by applying a 2D + time wavelet-Fourier transform. For efficient coverage of k-space, we have used a modified version of multi shot (interleaved) spirals trajectories. In order to reduce incoherent aliasing artifact, we use different random undersampling pattern for each temporal frame. Finally, we have used nonuniform fast Fourier transform (NUFFT) algorithm to reconstruct the image from the non-uniformly acquired samples. The proposed approach was tested in simulated and cardiac cine MRI data. Results show that higher acceleration factors with improved image quality can be obtained with the proposed approach in comparison to the existing state-of-the-art method. The flexibility of the introduced method should allow it to be used not only for the challenging case of cardiac imaging, but also for other patient motion where the patient moves or breathes during acquisition. (C) 2015 Elsevier Inc. All rights reserved.
引用
收藏
页码:10 / 19
页数:10
相关论文
共 40 条
  • [1] Candès EJ, 2008, IEEE SIGNAL PROC MAG, V25, P21, DOI 10.1109/MSP.2007.914731
  • [2] A Framework for Generalized Reference Image Reconstruction Methods Including HYPR-LR, PR-FOCUSS, and k-t FOCUSS
    Chen, Liyong
    Samsonov, Alexey
    DiBella, Edward V. R.
    [J]. JOURNAL OF MAGNETIC RESONANCE IMAGING, 2011, 34 (02) : 403 - 412
  • [3] Feng L., 2015, J MAGN RESONANCE IMA
  • [4] Golden-Angle Radial Sparse Parallel MRI: Combination of Compressed Sensing, Parallel Imaging, and Golden-Angle Radial Sampling for Fast and Flexible Dynamic Volumetric MRI
    Feng, Li
    Grimm, Robert
    Block, Kai Tobias
    Chandarana, Hersh
    Kim, Sungheon
    Xu, Jian
    Axel, Leon
    Sodickson, Daniel K.
    Otazo, Ricardo
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2014, 72 (03) : 707 - 717
  • [5] Accelerated Cardiac T2 Mapping using Breath-hold Multiecho Fast Spin-Echo Pulse Sequence with k-t FOCUSS
    Feng, Li
    Otazo, Ricardo
    Jung, Hong
    Jensen, Jens H.
    Ye, Jong C.
    Sodickson, Daniel K.
    Kim, Daniel
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1661 - 1669
  • [6] Nonuniform fast Fourier transforms using min-max interpolation
    Fessler, JA
    Sutton, BP
    [J]. IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2003, 51 (02) : 560 - 574
  • [7] Glover GH, 1999, MAGNET RESON MED, V42, P412, DOI 10.1002/(SICI)1522-2594(199908)42:2<412::AID-MRM25>3.0.CO
  • [8] 2-U
  • [9] Guo XL, 2008, 2008 PROCEEDINGS OF INFORMATION TECHNOLOGY AND ENVIRONMENTAL SYSTEM SCIENCES: ITESS 2008, VOL 2, P12
  • [10] Single heartbeat cardiac tagging for the evaluation of transient phenomena
    Herzka, DA
    Derbyshire, JA
    Kellman, P
    McVeigh, ER
    [J]. MAGNETIC RESONANCE IN MEDICINE, 2005, 54 (06) : 1455 - 1464