Remote measurement of cardiopulmonary signal using an unmanned aerial vehicle

被引:15
作者
Al-Naji, Ali [1 ,2 ]
Perera, Asanka G. [1 ]
Chahl, Javaan [1 ,3 ]
机构
[1] Univ South Australia, Sch Engn, Mawson Lakes, Australia
[2] Middle Tech Univ, Elect Engn Tech Coll, Baghdad, Iraq
[3] Def Sci & Technol Grp, Joint & Operat Anal Div, Melbourne, Vic, Australia
来源
AEROTECH VII - SUSTAINABILITY IN AEROSPACE ENGINEERING AND TECHNOLOGY | 2018年 / 405卷
关键词
HEART-RATE; NONCONTACT; DECOMPOSITION; ARTIFACTS; TOOL;
D O I
10.1088/1757-899X/405/1/012001
中图分类号
V [航空、航天];
学科分类号
08 ; 0825 ;
摘要
This study proposes a computer vision-based system to reveal the cardiopulmonary signal of humans in both static and dynamic scenarios without the need for restricting or contact. The proposed system extracts the signal based on the optical properties of skin colour variations in the facial region using image sequence analysis captured by a hovering drone while being convenient, safe and also cost-effective. The experimental results showed very good agreement, strong correlation coefficients and acceptable error ratios in comparison to reference instruments ( finger pulse oximeter and Piezo respiratory belt). Therefore, the proposed system in this paper may be suitable to be applied to detect human physiological parameters in war zones and natural disasters when the contact with the subject is difficult or impossible.
引用
收藏
页数:10
相关论文
共 51 条
  • [1] Abbas A, 2009, WORLD C MED PHYS BIO
  • [2] Remote Optical Cardiopulmonary Signal Extraction With Noise Artifact Removal, Multiple Subject Detection & Long-Distance
    Al-Naji, Ali
    Chahl, Javaan
    [J]. IEEE ACCESS, 2018, 6 : 11573 - 11595
  • [3] Detection of Cardiopulmonary Activity and Related Abnormal Events Using Microsoft Kinect Sensor
    Al-Naji, Ali
    Chahl, Javaan
    [J]. SENSORS, 2018, 18 (03)
  • [4] Al-Naji A, 2017, IEEE J TRANSL ENG HE, V5, DOI 10.1109/JTEHM.2017.2757485
  • [5] Monitoring of Cardiorespiratory Signal: Principles of Remote Measurements and Review of Methods
    Al-Naji, Ali
    Gibson, Kim
    Lee, Sang-Heon
    Chahl, Javaan
    [J]. IEEE ACCESS, 2017, 5 : 15776 - 15790
  • [6] Remote monitoring of cardiorespiratory signals from a hovering unmanned aerial vehicle
    Al-Naji, Ali
    Perera, Asanka G.
    Chahl, Javaan
    [J]. BIOMEDICAL ENGINEERING ONLINE, 2017, 16
  • [7] Al-Naji Ali, 2017, Journal of Medical Engineering & Technology, V41, P396, DOI 10.1080/03091902.2017.1313326
  • [8] Noncontact Heart Activity Measurement System Based on Video Imaging Analysis
    Al-Naji, Ali
    Chahl, Javaan
    [J]. INTERNATIONAL JOURNAL OF PATTERN RECOGNITION AND ARTIFICIAL INTELLIGENCE, 2017, 31 (02)
  • [9] Ali A, 2017, INT J IMAGE GRAPHICS, V17
  • [10] [Anonymous], 2011, IEEE INT C AC SPEECH