Fiber Technology for Reliable Repair of Skeletal Muscle

被引:7
作者
Franklin, J. E. [1 ]
Marler, J. J. [2 ]
Byrne, M. T. [3 ]
Melvin, A. J. [3 ]
Clarson, S. J. [1 ]
Melvin, D. B. [2 ,3 ]
机构
[1] Univ Cincinnati, Dept Chem & Mat Engn, Cincinnati, OH 45221 USA
[2] Univ Cincinnati, Dept Surg, Cincinnati, OH USA
[3] Surgical Energet Inc, Cincinnati, OH 45221 USA
基金
美国国家卫生研究院;
关键词
poly(ethylene terephthalate); PET; muscle; repair; polymer; surgery; ABDOMINAL-WALL; RETENTION SUTURES; CLOSURE; DEHISCENCE; INCISIONS; STRENGTH; WOUNDS; MESH;
D O I
10.1002/jbm.b.31280
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Conventional soft-tissue reclosure methods-sutures and staples-require substantial organized-collagen content. Some tissues lack extensive intrinsic collagenous content. Wound disruption consequences range from newly closed abdominal wounds bursting open, to post-cesarean wombs splitting at delivery, to heart valves loosening. Although sutures do approach the theoretical limit of normal force transfer-cross-sectional area times compressive strength, a different paradigm-shear force transfer across the far greater surface attainable by fine fibers parallel to the potential disruptive force could exceed that theoretical limit. Capacity is now the product of frictional coefficient, existing tissue pressure, and contact area. Using a device comprising bundles of poly(ethylene terephthalate) fibers through tissue, we previously coupled muscles to devices and bones. Here we tested an analogous device for reclosing fascia-stripped abdominal wall muscles. In 28 rabbits, fascia-deprived rectus abdominus muscles were reclosed, using the experimental device or conventional sutures. Testing muscles from the 21 three-week survivors, (with closure devices retained-the usual clinical practice) demonstrated experimental failure strength which exceeded that of controls by 58%. Histologically, solid tissue elements did in-grow between fibers for an extensive tissue-prosthetic interface. Both histology and mechanical performance suggest the fiber technology presented herein surpasses conventional sutures in closure of collagen-deficient tissues. (C) 2008 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater 9013: 259-266, 2009
引用
收藏
页码:259 / 266
页数:8
相关论文
共 28 条
[1]  
BERG RA, 1982, METHOD ENZYMOL, V82, P372
[2]   NEW SPECTROPHOTOMETRIC METHOD FOR DETERMINATION OF PROLINE IN TISSUE HYDROLYZATES [J].
BERGMAN, I ;
LOXLEY, R .
ANALYTICAL CHEMISTRY, 1970, 42 (07) :702-&
[3]  
Cengiz Y, 2001, EUR J SURG, V167, P60
[4]   Pregnancy after classic cesarean delivery [J].
Chauhan, SP ;
Magann, EF ;
Wiggs, CD ;
Barrilleaux, PS ;
Martin, JN .
OBSTETRICS AND GYNECOLOGY, 2002, 100 (05) :946-950
[5]   Abdominal incision wound breakdown [J].
Cliby, WA .
CLINICAL OBSTETRICS AND GYNECOLOGY, 2002, 45 (02) :507-517
[6]  
ELLIS H, 1977, ANN ROY COLL SURG, V59, P382
[7]  
FARRAR D, 1992, J HEART LUNG TRANSPL, V11, P341
[8]  
FUNG YC, 1994, 1 COURSE CONTINUUM M, P197
[9]  
Gislason H, 1999, EUR J SURG, V165, P958
[10]  
JOHNSON BW, 1982, ARCH SURG-CHICAGO, V117, P1189